Salamander water pump repair and re-purpose in our rainwater harvesting system.

  Рет қаралды 8,200

Andy Reynolds

Andy Reynolds

Күн бұрын

Repairs to a salamander electric pump that was going to be scrapped, to then replace the existing 110 universal brush motor pump in our rainwater harvesting system.
Please follow these links to support more videos.
Donate: www.paypal.com...
Support: / windandsolarelectricity
Cheers

Пікірлер: 29
@rongrip1
@rongrip1 5 жыл бұрын
Always great information Andy ... thanks so much
@TheInfoworks
@TheInfoworks 5 жыл бұрын
Ron, thanks for the appreciation, cheers
@massimobroccoli9854
@massimobroccoli9854 5 жыл бұрын
The same here Andy , Danfoss pump will not start up most of the time faulty capacitor ! Good video !
@TheInfoworks
@TheInfoworks 5 жыл бұрын
Caps don't last if they are somewhere warm and that's where they seem to be fitted, cheers
@riklee
@riklee 3 жыл бұрын
Thanks, nice video
@TheInfoworks
@TheInfoworks 3 жыл бұрын
Thanks for the comment, simple fix and re-purpose, subscribed? cheers
@hassf419
@hassf419 9 ай бұрын
Can you connect the wires to any of the capacitor spades ? Or do they have to go in a certain order ?
@TheInfoworks
@TheInfoworks 9 ай бұрын
Hi, yes an AC capacitor has no polarity, so any way round. It's the DC ones that need to be the right way round, cheers
@hassf419
@hassf419 9 ай бұрын
@TheInfoworks thank you so munch. Really hope this fix works for me once received the capacitor
@TheInfoworks
@TheInfoworks 9 ай бұрын
As you have seen, ithas worked for me several times, cheers @@hassf419
@AshleyWragg
@AshleyWragg 3 жыл бұрын
So, just checking, you basically bipassed the circuitry, so mains is connected to a motor? Thanks for the video 👍
@TheInfoworks
@TheInfoworks 3 жыл бұрын
Hi, yes and changed the duff capacitor. Although the control circuitry worked it was not necessary for the my use as I think it was some form of back pressure sensor. subscribed? cheers
@sim6699
@sim6699 5 жыл бұрын
I've seen videos of capacitor banks to start cars, wonder if the battery would last longer not taking the strain of high current draw. Its the same on generators not producing power after the capacitor failed, although now they use circuit boards for voltage control but more to go wrong.
@TheInfoworks
@TheInfoworks 5 жыл бұрын
Hi, the benefit of the quick charge / discharge is the phase shift for starting, cheers
@karolinapawlak132
@karolinapawlak132 8 ай бұрын
Mine only works at the one side as the hot water wasn’t going we turn it and now cold one is not going any advice 🙏
@TheInfoworks
@TheInfoworks 8 ай бұрын
Hi, is the motor spinning? are there any servo-valves in the system that are stuck? You may have to take it out to test, cheers
@karolinapawlak132
@karolinapawlak132 8 ай бұрын
Hi pump is going ok just with the cold water when i try to turn tap to hot one or open hot water not working at all no motor going with hot water
@karolinapawlak132
@karolinapawlak132 8 ай бұрын
@@TheInfoworks i dont thing so we have any servo its old system with the tank in the loft 😢
@karolinapawlak132
@karolinapawlak132 8 ай бұрын
@@TheInfoworks we have salamander pump and thats a second salamander pump which stop working properly after not even 2 years 1st one was 1.5 bar that one is 2.0 bars my husband turn it around and now hot water is going but cold one not
@TheInfoworks
@TheInfoworks 8 ай бұрын
Sounds like the motor is stalling when both pumps are working, I suspect a bad capacitor, cheers@@karolinapawlak132
@chrisellwood3523
@chrisellwood3523 2 жыл бұрын
I have this same problem where can I get a replacement cap?
@TheInfoworks
@TheInfoworks 2 жыл бұрын
Hi, I'm sure an on line search or even Ebay will provide. Hope you enjoy my other videos, cheers
@chrisellwood3523
@chrisellwood3523 2 жыл бұрын
@@TheInfoworks I called Salamander they say their caps are specially made and they dont know or sell a replacement :)
@TheInfoworks
@TheInfoworks 2 жыл бұрын
@@chrisellwood3523 Chris, that's just corporate marketing nonsense designed to sell more units and create tons of waste. I showed what I did and that is successful, but if don't feel like improving your skills then there's no more to say, all the best, cheers
@chrisellwood3523
@chrisellwood3523 2 жыл бұрын
@@TheInfoworks I changed the cap from a new motor and still just hummed with no motion. The new motor was silent until I turned it upside down. Must have been another issue , not the cap
@TheInfoworks
@TheInfoworks 2 жыл бұрын
@@chrisellwood3523 Yes there are pressure water flow sensors in the output connection that i disconnect when using these pumps for other uses. Turning the motor over activates the sensor gates, cheers
INCREDIBLE MAGNETIC Water Pump!!! putting her to the test
10:24
EL ANGELITO
Рет қаралды 1,9 МЛН
Stuart turner pump repair
9:40
Sebastian Hibbert
Рет қаралды 83 М.
Un coup venu de l’espace 😂😂😂
00:19
Nicocapone
Рет қаралды 11 МЛН
How I Turned a Lolipop Into A New One 🤯🍭
00:19
Wian
Рет қаралды 11 МЛН
🕊️Valera🕊️
00:34
DO$HIK
Рет қаралды 9 МЛН
Shower Pump Repair - plumbing optional
10:03
Eds drafts
Рет қаралды 3,7 М.
5 things to consider when buying or replacing your shower pump
6:53
The Shower Doctor
Рет қаралды 125 М.
How Does a Hydraulic Ram Pump Work?
8:56
Practical Engineering
Рет қаралды 7 МЛН
How Regenerative Braking Works.
23:01
Jeremy Fielding
Рет қаралды 280 М.
Why does a Brushless motor (BLDC) have 3 Wires
10:46
RCexplained
Рет қаралды 38 М.
Barn Find - What Is It - 1940's? Mystery Device Teardown!
15:10
Mr Carlson's Lab
Рет қаралды 285 М.
Stuart Turner Pumps - Seal Replacement
13:57
ST TechAssist
Рет қаралды 8 М.
BOOST HOT WATER PRESSURE - CT Force pump
10:49
plumberparts
Рет қаралды 378 М.
Un coup venu de l’espace 😂😂😂
00:19
Nicocapone
Рет қаралды 11 МЛН