Thank you for the video! But do you have a less complicated and expensive way to do this test?
@marshwetland38085 жыл бұрын
Now you know why soil tests are so damned expensive!
@kodajoaquin66333 жыл бұрын
A tip : watch series on Flixzone. I've been using them for watching all kinds of movies these days.
@samevan40573 жыл бұрын
@Koda Joaquin Yea, I've been watching on flixzone} for months myself :)
@jeremiahlarry91053 жыл бұрын
@Koda Joaquin Yup, I've been using flixzone} for since december myself =)
@ryanernesto50383 жыл бұрын
@Koda Joaquin Yea, I've been watching on flixzone} for years myself =)
@mattestengineeringservices17897 жыл бұрын
Can you tell us a reference code for this salinity test???
@marshwetland38085 жыл бұрын
Microsiemens to decisiemens, divide by 1000 doesn't sound right. More like 100K. Also, isn't it important to scrape ALL the paste into the filter?
@henrysaw30913 жыл бұрын
Measurement unit of Microsiemens area in EC testing is Microsiemens per centimeter (μS/cm) but in area of decisiemens in EC testing is "per meter" decisiemens per meter (dS/m), not in "centimeter." Measurement unit of sample area is different. That's why Microsiemens and Decisiemens conversion factor is only divided by 1000.