Oscilloscope measurements in power electronics: I. Single ended probe

  Рет қаралды 9,591

Sam Ben-Yaakov

Sam Ben-Yaakov

Күн бұрын

Пікірлер: 26
@r_be
@r_be 5 жыл бұрын
Sam, I sincerely hope you never stop this power electronics series. Best of luck and thank you.
@sambenyaakov
@sambenyaakov 4 жыл бұрын
😊👍
@UpcycleElectronics
@UpcycleElectronics 5 жыл бұрын
Thank you very much. This is the most clear explanation I have seen on this subject, especially the last parts about the voltage ratings of parts, and the capacitive coupling of EMI through an isolation transformer. I have often wondered why modern oscilloscopes are not designed for isolation in the first place. Oscilloscopes have been built without any exterior metal for well over a decade. It seems to me that the standard practice of an earth reference is just an attempt at selling me overpriced differential probes. Now I must go watch your latest upload on differential probes to further isolate my ignorance. Thanks for the upload. -Jake
@sambenyaakov
@sambenyaakov 5 жыл бұрын
😊Thanks
@kokotmkokot4926
@kokotmkokot4926 4 жыл бұрын
Thank you very much for these videos!
@sambenyaakov
@sambenyaakov 4 жыл бұрын
Thanks for comment
@gillywild
@gillywild 5 жыл бұрын
Hi, firstly thank you very much for publishing these videos. I am enjoying them very much . You addressed the issue of floating the scope but not the practice of floating the DUT (the convertor being tested) in my experience this is the most common solution and I wondered what issues this could pose other than the isolation transformer must sometimes be very large and expensive?
@MrMropi
@MrMropi 4 жыл бұрын
thank you so much for these videos you are the best
@sambenyaakov
@sambenyaakov 4 жыл бұрын
👍😊
@BrijeshKumar_electrical
@BrijeshKumar_electrical Жыл бұрын
Thanks for the nice video on Oscilloscope... If there is any practical related to above discussion like effect due to ground voltage/current, effect due to flux during high frequency. Can we create artificial EMI and see the effect through oscilloscope. Regards
@sambenyaakov
@sambenyaakov Жыл бұрын
In any PCB that includes both power and signals you can clearly see these effects.
@user-mj3ef
@user-mj3ef 4 жыл бұрын
Please more basic courses in English. Great teaching thank you sir!
@sambenyaakov
@sambenyaakov 4 жыл бұрын
Thanks. Doing both.
@BogdanSerban
@BogdanSerban 5 жыл бұрын
Digital multi channel scopes can compare two signals, so channel 1 would be the gate and channel 2 the source (of the high side switch), and the ground clips are disconnected. The resolution and speed are poor, but at least you can do the measurement. I also thought about isolating the converter itself and not connecting the scope to the mains earth.
@sambenyaakov
@sambenyaakov 5 жыл бұрын
Ground clips need to be connected.
@petergriffin760
@petergriffin760 5 жыл бұрын
Does isolated channels oscillos (like FLUKE-190-104) do the trick with floating measurements?
@sambenyaakov
@sambenyaakov 5 жыл бұрын
Yes indeed. But notice they do not provide CMRR data.
@catalin3407
@catalin3407 5 жыл бұрын
Since you broight up the common mode problem, I have a question related to it. Isolated converters have a Y cap across the transformer to mittigate common mode problems. However, I could not found any relevant documentation on the subject on how to select such cap. It seems to me that it is trial and error ? Could you give your view on this ? Thanks.
@sambenyaakov
@sambenyaakov 5 жыл бұрын
Have a look at kzbin.info/www/bejne/a3-1mn-Fq9KLmqM it includes some relevant information. I do not recall any specific documentation on subject.
@catalin3407
@catalin3407 5 жыл бұрын
@@sambenyaakov thank you. Good information.
@grigorioss3936
@grigorioss3936 10 ай бұрын
Probably this has been solved by now, it's a question I was trying to answer myself recently. My thoughts is that you'd want to use the largest Y cap value possible (less impedance for CM noise to filter better), while adhering to leakage current regulations. Let me know if there's some more thorough guidance I can check for this.
@jubul1988
@jubul1988 4 жыл бұрын
Hi sir, can you please address my queries 1.power ground and analog ground should be common or different. 2. In a 3 phase inverter fed motor drive when using more than 48 volt battery why it is required to use isolated gate driver. 3. I have seen spike in current wave form and the mosfet failed when i used to probe vgs and vds .i am using isolated scope yokogawa dl850ev.what may be the possible reason . Thanks in advanve
@sambenyaakov
@sambenyaakov 4 жыл бұрын
1. Separated but them connected in one point. 2. The reason is high power 3. There are capacitive paths that can still nject noise.
@NiHaoMike64
@NiHaoMike64 5 жыл бұрын
You show wrapping the ground wire around the probe which is not desirable since that makes an inductor! I was taught to just hold the wire against the probe. I wonder why there aren't more scopes that are double insulated and therefore do not need a ground. As well as battery operated scopes that are basically ideal for floating measurements, especially for signals too small for a differential probe to resolve.
@sambenyaakov
@sambenyaakov 5 жыл бұрын
Thanks for good comments. Wrapping a bare wire on metal does not make a coil if tied. Differential probed are not that expensive anymore (save the high end) and they provide a very good solution for power electronics. For very low signal, true differential scope are around (e.g. Picoscope 4000 , if I remember right the number. I do own one).
@sambenyaakov
@sambenyaakov 5 жыл бұрын
Just realized that when referring to wrapping you meant the first mode I showed in video, wrapping of the isolated ground wire. You are right, but holding the wire against he probe is rather cumbersome. Thanks again for comment.
Basics of grounding and bypassing in power electronics PCB layout
26:50
SiC MOSFET datasheet and comparison to IGBT
50:21
Sam Ben-Yaakov
Рет қаралды 17 М.
Самый Молодой Актёр Без Оскара 😂
00:13
Глеб Рандалайнен
Рет қаралды 7 МЛН
I Can't Believe We Did This...
00:38
Stokes Twins
Рет қаралды 127 МЛН
Mom's Unique Approach to Teaching Kids Hygiene #shorts
00:16
Fabiosa Stories
Рет қаралды 21 МЛН
100❤️
00:19
MY💝No War🤝
Рет қаралды 23 МЛН
Differential oscilloscope probes: The common and the better
35:51
Sam Ben-Yaakov
Рет қаралды 8 М.
BJT filters and capacitance multipliers
19:51
Sam Ben-Yaakov
Рет қаралды 3,4 М.
Current sharing of parallel connected MOSFETs: The facts
27:41
Sam Ben-Yaakov
Рет қаралды 9 М.
A primer to resonant DC-DC converters
20:33
Sam Ben-Yaakov
Рет қаралды 57 М.
MOSFET Turn-Off Snubber
27:58
Sam Ben-Yaakov
Рет қаралды 50 М.
EEVblog #14 - An unusual oscilloscope phenomenon!
10:00
EEVblog
Рет қаралды 96 М.
#186 Oscilloscope Bandwidth and Sample-Rate Explained with Test
21:09
Hard and soft switching of PWM converters
33:46
Sam Ben-Yaakov
Рет қаралды 69 М.
Every Component of a Switch Mode Power Supply Explained
23:10
ElectrArc240
Рет қаралды 167 М.
EEVblog #279 - How NOT To Blow Up Your Oscilloscope!
24:26
EEVblog
Рет қаралды 1 МЛН
Самый Молодой Актёр Без Оскара 😂
00:13
Глеб Рандалайнен
Рет қаралды 7 МЛН