SCALE FACTOR FOR RESPONSE SPECTRUM ANALYSIS

  Рет қаралды 17,432

CivilSAC

CivilSAC

Күн бұрын

Пікірлер: 28
@rahitharaghu7667
@rahitharaghu7667 Жыл бұрын
Short and simple...so helpful
@CivilSAC
@CivilSAC Жыл бұрын
Thanks.
@civilengineeringconcept4863
@civilengineeringconcept4863 2 жыл бұрын
short and simple.. nice brother liked it♥️✔🎉🎊
@nakshsharma6661
@nakshsharma6661 2 жыл бұрын
Scale factor value in x direction is double in scale y direction and if mass participation period scale is more first mode what is the problem. Please suggest me
@pragatidapurkar8834
@pragatidapurkar8834 3 жыл бұрын
Whats next step? After doing scalefactor
@gurhanatalay
@gurhanatalay 2 жыл бұрын
Hello sir, Im using SAP2000 for structural analysis. In response spectrum case, stress values on shell elements are seen as 0. When I define static seismic case with the values that produces same base shear, static case gives stress on shell elements but response spectrum case still not. How can I fix that? Is there any suggestion? Thanks in advance.
@tasneemzidan6802
@tasneemzidan6802 Жыл бұрын
Hello, just had a look at the CSI website and it seems that the scale factor is equal to Ig/R. Is there a reason why you divided by 2?
@CivilSAC
@CivilSAC Жыл бұрын
Ig/2R is used for IS 1893 code however Ig/R is used with ASCE 7. I hope this clears things up.
@shrinidhinavale4324
@shrinidhinavale4324 2 жыл бұрын
Hello sir.. I would like to know about the source/code book from where formula for scale factor. Ig/2R is used.
@CivilSAC
@CivilSAC 2 жыл бұрын
You refer to the CSI website.
@ajitkurey5225
@ajitkurey5225 3 жыл бұрын
Scale factor will be same or differ for Time history
@CivilSAC
@CivilSAC 3 жыл бұрын
The scale factor will be different for different time histories.
@rolandalphs7022
@rolandalphs7022 3 жыл бұрын
Hello! Im currently studying civil engineering. Should i rescale the scale factor if the response spectrum base shear turns out to be higher? Any insights on when we should or should not?
@CivilSAC
@CivilSAC 3 жыл бұрын
According to IS 1893-2016 part-1, If the design base shear from the equivalent static method is coming out to be less than the base shear from dynamic analysis, the scaling should be done as given in the code.
@engineerjirel4565
@engineerjirel4565 4 жыл бұрын
what is the meaning of scaling upto base shear due to EQ? what happens when we dont scale up?
@CivilSAC
@CivilSAC 4 жыл бұрын
Dynamic analysis has many uncertainties. To ensure safety if the base shear is less than the base shear from the equivalent static load method, we have to scale it up.
@engineerjirel4565
@engineerjirel4565 4 жыл бұрын
@@CivilSAC thank u sir subscribed ur channel
@qureshitaqweemshakil80
@qureshitaqweemshakil80 3 жыл бұрын
How to calculate scale factor for time history data
@CivilSAC
@CivilSAC 3 жыл бұрын
Please refer to this video on my channel kzbin.info/www/bejne/jnK0pWyFd5d-jcU
@pushkarchavan7437
@pushkarchavan7437 4 жыл бұрын
Initially we are taking scale factor as If/2R why??? Please tell the reason and reference..I Am taking it as 1 in spectrum case..plz help..
@CivilSAC
@CivilSAC 4 жыл бұрын
The response spectrum given in the IS1893 code is elastic. By using this scale factor we consider the Response reduction factor R which considers the ductility in the building. We also consider I in the scale factor. You can refer to the CSI America website for further reference.
@nraj2597
@nraj2597 3 жыл бұрын
@@CivilSAC now its not needed in updated version of etabs for 1st time analysis factor should be (g) I have checked with manual calculation. In website that wiki page that was uploaded in 2012 and for old versions
@mukundkrishna5161
@mukundkrishna5161 3 жыл бұрын
@@nraj2597 Are you sure sir? I am also getting some huge scale factors like 30-35 when I am doing large building designs. even I noticed that CSI website was giving the answer for old versions. So Initially should I take a scale factor of 9.8 in my analysis??Pls help.
@narendrajadhav1224
@narendrajadhav1224 Жыл бұрын
What is for if V2 is>V1
@CivilSAC
@CivilSAC Жыл бұрын
No, need to scale.
@structurelearninghub3340
@structurelearninghub3340 3 жыл бұрын
Here scale factor must be 9.81
@CivilSAC
@CivilSAC 3 жыл бұрын
If your unit of acceleration is m/s2, then you can use 9.81.
Seismic Analysis of Multi-Story Buildings using the Response Spectrum Method
27:34
Dr Nafie - Structural Engineering
Рет қаралды 65 М.
Scale Factor in Response Spectrum In Staad
9:09
Torq
Рет қаралды 2,8 М.
Lamborghini vs Smoke 😱
00:38
Topper Guild
Рет қаралды 57 МЛН
Lazy days…
00:24
Anwar Jibawi
Рет қаралды 8 МЛН
Players push long pins through a cardboard box attempting to pop the balloon!
00:31
Base Shear Scaling in ETABS | 2 Methods of Scaling You Have to Know
5:43
The Structural World
Рет қаралды 7 М.
Response Spectrum Analysis | Etabs19
17:13
StructGURU
Рет қаралды 16 М.
Tutorial_5 : Applying Vertical Seismic Shaking for RC towers in ETABS as per Indian Seismic Code.
12:11
Dr. Manmohan Maniyar Structural Engineering
Рет қаралды 6 М.
How to Define Scale Factor for Earthquake Analysis in ETABS
2:58
WEBINAR: Response Spectra Analysis using ETABS
29:19
Computers and Structures, Inc.
Рет қаралды 26 М.
Etabs 2015 - Response Spectrum Analysis
17:44
Civilknowhow Tutorials
Рет қаралды 152 М.
What is a Response Spectrum Analysis? and How to use it in Seismic Design of Structures?
12:59
Dr Nafie - Structural Engineering
Рет қаралды 119 М.