what is Sludge volume index | SVI kise kahte hai | Hindi |

  Рет қаралды 25,292

ETP Knowledge Junction

ETP Knowledge Junction

Күн бұрын

Sludge volume index is
the standard measure of the physical characteristics of activated sludge processes. It is defined as 'the volume (in mL) occupied by 1 gram of activated sludge after settling the aerated liquid for 30 minutes'.
Significance :
•Its represent the degree of concentration of the sludge in the system and hence Decide the rate of recycle of sludge require to maintain the desired MLLS (mixed liquor suspended solids).
•SVI gives a more accurate picture of the sludge settling characteristics than settleability or MLSS alone.
•SVI used to indicate the physical state of sludge produced in a biological aeration system.
SVI (mL/g) = settled sludge volume (mL/L) X 1000/mixed liqour suspended solids(MLSS)(mg/L)
Range: 50 to 150mL/gm (its indicate good settling sludge).
#etpknowledgejunction
#science_classes
#sludge_volume_index
#chemical_oxygen_demand
#biochemical_oxygen_demand #Importance_of_BOD_and_COD #Wastewater_treatment #waste_water_treatment #activated_sludge_process
#sanjeet_rawat
#microorganisms_and_BOD
#food_and_mass_ratio #nurtureflora #wastemanagement #wastewater
________________________________________________
Watch the full videos and keep supporting the channel.
Food and mass ratio::
• What is Food to Mass R...
ETP Q & A || sawal jawab::
• ETP Q&A || sawal jawab...
Biochemical oxygen demand::
• What is Biochemical ox...
Standard procedure for analysis of mlvss and mlss::
• Procedure of MLSS and ...
Standard procedure for Analysis of Dissolve Oxygen::
• Dissolved oxygen analy...
Standard procedure for chemical oxygen demand::
• Chemical oxygen demand...
effluent treatment plant :: • What is Effluent treat...
you can ask any question to us by social media and we will try to solve your queries so please follow us on social media.
Stay tuned with the science classes by following on social media:
Facebook:: / scienceclassesofficial
Instagram:: / iamsanjeetrawat (personal)
/ etpknowledgejunction

Пікірлер: 117
@lalitshivhare1938
@lalitshivhare1938 4 жыл бұрын
stp plant wale Bhaiyo hamse bhi touch me raho taki ek dusre ki problem me sahyog kar sake.. Baki ye sir very clearty ke sath hamara sahyog karte he isliye hame bhi inhe aage badana chiye.. Like and comment deke sir ke hosle ko majbuti do taki hame hamare kam me achi clearty bani rahe .
@lalitshivhare1938
@lalitshivhare1938 4 жыл бұрын
I mean fb pe request bhej kar frnd bane or ek dusre Ka sahyog Kare.. ETP and STP ..etc
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
facebook.com/scienceclassesofficial/
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Bilkul
@rakeshdeshmukh7622
@rakeshdeshmukh7622 4 жыл бұрын
Nice series sir .no one tells this type of information on KZbin
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Thanks dear...stay connected also motivated ur colleagues.
@gc19208
@gc19208 3 жыл бұрын
Very Important Information, Thanks 👍
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
Thanks for your appreciation you can support me on patreon and ask your queries personally. Please go through the link www.patreon.com/etpknowledgejunction
@Yathu-yy8uo
@Yathu-yy8uo 16 күн бұрын
🎉
@kumart5711
@kumart5711 4 жыл бұрын
very good explanation ,then all other sources available on youtube
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Thanks sir... Please stay connected 🙏
@pranavchaure10
@pranavchaure10 7 ай бұрын
Mlss 2250 mg per litre , half hour setting 580 ml , SVI coming up around 250 .....what to do
@ETPKnowledgeJunction
@ETPKnowledgeJunction 7 ай бұрын
What is SVI wali video me solution bhi diya hua h.. Plzz watch properly. Please join the telegram group ETP knowledge junction.
@SubodhAchrekar
@SubodhAchrekar Жыл бұрын
Sir, How to calculate MLSS & MLVSS mg/ltr. (roughly) on the basis of SVI
@PardeepSingh-er5xb
@PardeepSingh-er5xb 5 ай бұрын
Aeration tank me sv not settling 15000 / 16000 mlss sludge volume kise settle kar sakte hye g
@ETPKnowledgeJunction
@ETPKnowledgeJunction 5 ай бұрын
15K .. 16K se MLSS ko 3500ppm pr leke aao.
@mehulraj3035
@mehulraj3035 4 жыл бұрын
Sir please make video on nitrification and denitrification
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Mitra I will try
@nileshamritkar8510
@nileshamritkar8510 Жыл бұрын
Sir, Clarifier me top side sludge floating ho Raha hai, please help me
@SujeetKumar-ru7er
@SujeetKumar-ru7er 8 ай бұрын
Sir mera sugar mill ka ETP hai usme abhi problm ye aa rahi hai ki mlss 500 mg/ltr hai lekin settling 40% hai mai Continue mls bahr nikal raha hun agr nikalu nahi to settling baht slow ho jati hai 1000ml ka cylender mein 30 minut ki settling 500 par show kar rahi hai aur jaise hi effluent lete hai tabhi settling kuch der bad 800 ke karib dikhati hai aur aeration ki cod 500 aa rahi hai
@ETPKnowledgeJunction
@ETPKnowledgeJunction 8 ай бұрын
Aapko sludge drain nahin karna hai balki aapko sludge ki quantity aur quality Badhani hai apne aeration tank mein. abhi ki condition se yah Pata Chalta Hai ki aapke aeration tank mein jo sludge hai vah naya hai aur vah secondary clarifier Mein proper settle Nahin ho raha hai. Jab sludge thoda aged ho jata hai ya purana ho jata hai to vah proper tarike se secondary clarifier Mein settle ho jata hai aur bod bhi acchi Tarah Se remove karta ha. dusra ki aapka mlss bahut kam hai aapko MLSS bhi Badhana Hoga. main aapko teen videos recommend kar raha hun. Pahli video hai sludge volume index per, dusri video hai activated sludge process per aur Teesri video hai MLSS and MLVSS per. kzbin.info/www/bejne/o6S3nKmphd5rqK8si=oGiUczLRwBzi3uo5 kzbin.info/www/bejne/baPSioRpn7KJepYsi=gqpP5lxvQidp6LgU kzbin.info/www/bejne/Zn6zl6WHi5aXnJIsi=-1IjZtbbnwt-91n8
@kamallovelykhan5442
@kamallovelykhan5442 5 ай бұрын
Urea DAP,Sahi Matra me use kro. Slugde drain nhi kre,Use aur Solid kre ,
@prasunmondal8002
@prasunmondal8002 3 жыл бұрын
What is the optimum VFA level in anaerobic digestion process in ETP?
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
The ratio of VFA to Alkalinity shall be in range 0.05 to 0.15
@mukeshbairwa4226
@mukeshbairwa4226 Жыл бұрын
Sir, MLSS ka sample lene ke liye ek SBR tank mein Sewage kitna level hona chahiye
@ETPKnowledgeJunction
@ETPKnowledgeJunction Жыл бұрын
Jis level pr aap aeration shuru krte ho
@dhirenpandya9659
@dhirenpandya9659 3 жыл бұрын
Can you explain Fenton Treatment ?
@rahulrohit1455
@rahulrohit1455 4 жыл бұрын
Explain Biomass loading and cod load calculationa
@muhammadjaan4053
@muhammadjaan4053 3 жыл бұрын
Sir Svi check Kia a mgr sludge q nai bhete Raha a Kia waja a or es ka Kia solution a
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
Maine iss vishay par bhi video bnai h... Activated sludge process wali... Aur bhi bnai h ek baar ap dekh lo sbb
@prahladsinghchouhan2821
@prahladsinghchouhan2821 4 жыл бұрын
Sir mere ko Naclo (sodium hypochlorite) me chlorine kitane parsenteach he batna
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Product details mein likhi hongi.
@rakeshdeshmukh7622
@rakeshdeshmukh7622 4 жыл бұрын
How to calculate etp plant capacity (per day)
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Your final aeration tank
@shanindia9761
@shanindia9761 3 жыл бұрын
Exactly kitna svi rehna chahiye sir ek healthy or active aeration k liye
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
50 to 150
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
kzbin.info/www/bejne/apnZoZpppbefqMk watch this
@avinashmokashe527
@avinashmokashe527 2 жыл бұрын
✨ Thank you
@avinashmokashe527
@avinashmokashe527 2 жыл бұрын
Sir ✨
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
Join telegram group ETP Knowledge Junction
@avinashmokashe527
@avinashmokashe527 2 жыл бұрын
@@ETPKnowledgeJunctionyes Sir please send link Sir... ✨ Thanks
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
Open your telegram and search ETP Knowledge Junction
@rammaurya8356
@rammaurya8356 4 жыл бұрын
Sir ek video MBBR, MBR aur FBBR par banaye.
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
I'll try dost
@shivsafe777
@shivsafe777 4 жыл бұрын
Very useful subject
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Thanks sir
@shivamnsikanpur5042
@shivamnsikanpur5042 2 жыл бұрын
Aeration tank me bacteria kaise tayar kare
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
Watch other videos also
@lalhriatpui2506
@lalhriatpui2506 4 жыл бұрын
sludge volume index can be controlled by???
@waleedkhan31
@waleedkhan31 2 жыл бұрын
Sir ham apni svi ksy zeyada kar sakty han and areation tank me kya food dalin jo hamary suldge zeyada ho jay
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
Maintain fm ratio
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
Fm ratio wali video dekho
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
You can join telegram group ETP Knowledge Junction
@dhanapatil8258
@dhanapatil8258 3 жыл бұрын
एरेशन टॅन्क मे पीएच व्हॅल्यू मे फर्क पडता है क्या ???? कम होना या पीएच बठना ????
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
Samjha nahi main aapka question.
@lalitshivhare1938
@lalitshivhare1938 4 жыл бұрын
Sir SVI best quality ke liye kitne ml/g hona chahiye ..
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Range: 50 to 150mL/gm (its indicate good settling sludge).
@varunchaubey1526
@varunchaubey1526 Жыл бұрын
Sir usualy svi kitana hona chahiye aeration tank me
@ETPKnowledgeJunction
@ETPKnowledgeJunction Жыл бұрын
Hi dear, watch the new video on SVI.
@ETPKnowledgeJunction
@ETPKnowledgeJunction Жыл бұрын
kzbin.info/www/bejne/baPSioRpn7KJepY ye
@singwithss2824
@singwithss2824 4 жыл бұрын
Sir flash mixer tank me ph 9 rahata hai aur pst tank me ph 6 ho jata hai aisa kyo please reply sir ji
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Flash mixture mein aap aur kya kya add karte ho??? PST ka full form kya hai. aapke PST aur flash mixture ke bich mein kaun kaun se stages hai aur aap vahan per kya kya karte ho??
@somshil498
@somshil498 3 жыл бұрын
@@ETPKnowledgeJunction brother I think pst means primary settling tank
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
Yes
@ravikumargoswami1013
@ravikumargoswami1013 3 жыл бұрын
Why is the pH of aeration decreasing. While we feed 8.5 PH
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
Watch more videos will get the answer itself
@bagadakishan385
@bagadakishan385 3 жыл бұрын
Nitrification process take place in aeration tank.
@shanindia9761
@shanindia9761 3 жыл бұрын
@@bagadakishan385 i think denitrification process bro
@SameerSameer-hk4qq
@SameerSameer-hk4qq 4 жыл бұрын
Sir mere ETP plant main foming zyada ho rhi kya kre.
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
kzbin.info/www/bejne/sIPQi2OvabqFbZI Watch this video about excess foaming in aeration tank.
@SameerSameer-hk4qq
@SameerSameer-hk4qq 4 жыл бұрын
Ok sir
@prahladsinghchouhan2821
@prahladsinghchouhan2821 4 жыл бұрын
Sir mere ETP Biological foming jada ku hothi he
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
Chauhan ji, forming ke liye 2 videos Bani Hui Hain. ek video bilkul basic wali hai. Tum channel mein jakar "eccess forming" wali video dekhna aur ek "ETP Q&A" wali video hai usmein bhi Kai logon ne Mujhe sawal poochha tha foaming ke upar unke answer bhi Maine details mein de rakhe hain. fir bhi agar koi chij samajh mein Na aaye to dobara puchna. Excess foaming::kzbin.info/www/bejne/sIPQi2OvabqFbZI ETP Q&A::kzbin.info/www/bejne/eISboWCll62Wpq8
@vipinkumar8809
@vipinkumar8809 4 жыл бұрын
Sir svi calculation of details with example
@ETPKnowledgeJunction
@ETPKnowledgeJunction 4 жыл бұрын
SVI (mL/g) = settled sludge volume (mL/L) X 1000/mixed liqour suspended solids(MLSS)(mg/L) Range: 50 to 150mL/gm (its indicate good settling sludge).
@IbrahimAhmed-ci7zy
@IbrahimAhmed-ci7zy Жыл бұрын
wrong spelling of defination, it is definition
@ETPKnowledgeJunction
@ETPKnowledgeJunction Жыл бұрын
Hi Ibrahim, Thanks dear stay connected ❤️
@sujeetgaming5777
@sujeetgaming5777 3 жыл бұрын
Sir svi ki koi kisi book unit nhi di jab index hai hai unit kha se hogi
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
Kya????
@SujeetKumar-ru7er
@SujeetKumar-ru7er 8 ай бұрын
Sir baht presan hun apki help chahiye
@govindraj-
@govindraj- Жыл бұрын
AREATION 2 tank sludge 200 settled bt aretion 3 tank not settling sludge
@ETPKnowledgeJunction
@ETPKnowledgeJunction Жыл бұрын
U can check the return sludge may be some problem with return sludge pump. Check return sludge point. Whether it is settling of floating.
@govindraj-
@govindraj- Жыл бұрын
Thank u sooo much sir
@govindraj-
@govindraj- Жыл бұрын
MLSS CHECKED COMING ABOVE 7500 SIR
@ETPKnowledgeJunction
@ETPKnowledgeJunction Жыл бұрын
What is 30 min. Settling?
@PradeepSingh-sn3qz
@PradeepSingh-sn3qz 3 жыл бұрын
Hii SV aeration ki kaise badhaye
@nafismansoori7849
@nafismansoori7849 3 жыл бұрын
Sir what is required volume of SVI
@somshil498
@somshil498 3 жыл бұрын
50 to 150
@kdg382
@kdg382 2 жыл бұрын
Sir app nom dena plz mujhe kooch poochna h plz sir am,opretor
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
Join telegram group ETP Knowledge Junction and Personally msg me on instagram iamsanjeetrawat
@VikasSingh-mf8nc
@VikasSingh-mf8nc 3 жыл бұрын
How to calculate sludge %
@anujyadavofficial2234
@anujyadavofficial2234 2 жыл бұрын
SvI is less then how to increase it
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
0.25 to 0.5
@SujeetKumar-ru7er
@SujeetKumar-ru7er 8 ай бұрын
Mere question answer agr kesi bhi bhai ke pas hai to plz help me
@ravindrachauhanrajput7814
@ravindrachauhanrajput7814 2 жыл бұрын
Aeration me sludge volume bbut Jayda h or hlka sludge h
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
Watch latest uploaded videos on KZbin channel ETP Knowledge Junction
@PANKAJKUMAR-tq8tw
@PANKAJKUMAR-tq8tw 3 жыл бұрын
SV 800 ML se upar aa rhi hai see kaise maintained kre
@nileshamritkar8510
@nileshamritkar8510 Жыл бұрын
Sir, Aapne kya Kiya
@nileshamritkar8510
@nileshamritkar8510 Жыл бұрын
Muje bi ye problem AA Rahi hai
@ramjeetkumaryada
@ramjeetkumaryada 5 ай бұрын
SV 30 kya hota hai
@ETPKnowledgeJunction
@ETPKnowledgeJunction 5 ай бұрын
Sludge volume 30..means 30 minutes ke liye jo aeration tank ka sample hum settling ke liye rakhte hn taki ye pta kar sake ki 30 min me kitna sludge settle ho rha h
@ramjeetkumaryada
@ramjeetkumaryada 5 ай бұрын
SV 30 KYA HAI
@mr.traveller..8961
@mr.traveller..8961 3 жыл бұрын
SVI Kitana chaiye
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
50 to 150 ml in per litre
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
Please go through the video description
@mr.traveller..8961
@mr.traveller..8961 3 жыл бұрын
@@ETPKnowledgeJunction Sir can you explain me cod proper definition
@ETPKnowledgeJunction
@ETPKnowledgeJunction 3 жыл бұрын
kzbin.info/www/bejne/n4Kbk5-unradsNk Watch this...and stay connected
@mr.traveller..8961
@mr.traveller..8961 3 жыл бұрын
TAN OR TKN Kitana imp rahta hai west water me
@padhiyarjay9129
@padhiyarjay9129 2 жыл бұрын
Mlss settle nahi hote hai
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
Watch latest uploaded videos
@ravindrachauhanrajput7814
@ravindrachauhanrajput7814 2 жыл бұрын
Sir plz help me
@ETPKnowledgeJunction
@ETPKnowledgeJunction 2 жыл бұрын
?
@suhelkhan8049
@suhelkhan8049 2 жыл бұрын
Pehle khud sekh le
@wolverine198
@wolverine198 Жыл бұрын
Faltu
@SameerSameer-hk4qq
@SameerSameer-hk4qq 4 жыл бұрын
Sir mere ETP plant main foming zyada ho rhi kya kre.
@garhwaldiary5919
@garhwaldiary5919 4 жыл бұрын
Bro..... Watch previous video...
@sushantsangle682
@sushantsangle682 3 жыл бұрын
Same problem bro
What is Biochemical oxygen demand || What is BOD || @ETPKnowledgeJunction
5:06
ETP Knowledge Junction
Рет қаралды 23 М.
Офицер, я всё объясню
01:00
История одного вокалиста
Рет қаралды 6 МЛН
Кәсіпқой бокс | Жәнібек Әлімханұлы - Андрей Михайлович
48:57
ETP Q&A || sawal jawab || @ETPKnowledgeJunction
17:10
ETP Knowledge Junction
Рет қаралды 33 М.
How to Reduce SVI & Foam in Activated Sludge Plants
4:57
What is SVI (sludge volume index) | Sanjeet Rawat | @ETP Knowledge Junction
12:37
ETP Knowledge Junction
Рет қаралды 12 М.
Determination of Sludge Volume Index
7:46
SCoE_Civil_Env. Engg. Group
Рет қаралды 19 М.
Sludge Volume Index | Bulking of Sludge | Rising Sludge
19:12
SavEnviron
Рет қаралды 11 М.
Sludge Volume Index (SVI) | Waste Water Engineering
9:52