I have a Paslode air 1.5hp air nailer with a Rol-Air compressor. This summer the compressor would start slow and pop the circuit breaker. I replaced the start-up/run capacitor and it fixed the problem. However two months ago it started doing the same thing again. I tried everything and almost threw it away till I found your video and you stated it could be the extension cord being too long so I tried compressor without my 100 ft extension cord and that fixed my issue. Couldn't believe that a voltage drop from the cord would cause that problem. I tried some heavier gauge cords that were shorter and they also worked! Thanks for the video and useful and less obvious tips!
@tcveatch3 жыл бұрын
Me too. Winter work, kept popping the breaker, running very slow then dying or maybe a little faster. Watched this and put in a shorter heavier extension cord and bam it's working perfectly.
@1caqui5 жыл бұрын
Thank you! I had a leak under my pressure switch after air filled in tank. Tested the none return valve like you said, I replaced the none return valve and now my compressor is up and running.
@sealeytools5 жыл бұрын
This is great news. Thank you for taking the time to comment
@margheritamccaughey44516 жыл бұрын
Thank you for advice,you saved me alot of time,my head gasket was leaking.thanks have fun.
@sealeytools6 жыл бұрын
Thank you for sharing :)
@briain_odonnghaile3 жыл бұрын
Excellent advice well explained. Will that model be adequate for spraying?
@tonyv15055 жыл бұрын
youtube most useful social media tool in the net I can live without any other social media out there but without youtube we be going back to the old days when these local profesional used to rip us off all the time now we watch a video and do it ourselves and save a ton of money
@andrewjolley40076 жыл бұрын
I think i have found the problem with my sgs compressor thanks to this clip
@sealeytools6 жыл бұрын
That's great news Andrew! Thanks for sharing.
@antoniojoaochina2285 Жыл бұрын
The best explication
@briain_odonnghaile3 жыл бұрын
Just bought one today but there is air leaking from the non return valve straight out of the box. Washer and spring look ok, why is this? Luckily the store is local for a replacement, just curious why this should be happening.
@Thetrucky696 жыл бұрын
Excellent information.
@kenrosl3 ай бұрын
hi.i have the same compressor !after ca 1minute the rpm slows down and it stalling,no air leaking
@sealeytools3 ай бұрын
Hi. Feel free to contact our Technical Team on either 01284757505 or email technical@sealey.co.uk with the details, and they will be happy to help you. Thanks.
@alexmardueno7157 Жыл бұрын
Thx sr, i learn a lot to day
@N2693 жыл бұрын
Also, check the reduction valve. Sometimes that rubber seal needs some red rubber grease to help it seal. All part of a valve service I guess.
@shimie.853911 ай бұрын
Thanks, it was very helpful!
@sealeytools11 ай бұрын
Glad to hear that!
@rodrickdavidson68152 жыл бұрын
Thank you, very good video.
@phil363103 жыл бұрын
That was very helpful. Thank you !
@leon_mnl4 жыл бұрын
very useful video,great tips and tricks and told in a way that you don’t need a doctorate
@YOBSTATV4 жыл бұрын
If turn on my air compressor it did not run and i only heared a humming sound. Your advice pls. Thanks.
@Jumpmaster3373 жыл бұрын
Did you find out what went wrong?
@YOBSTATV3 жыл бұрын
No.. already changed the switch and capacitor but nothing new. my air compressor is FUJIMA 2HP brand new and just twice being used .
@Jumpmaster3373 жыл бұрын
@@YOBSTATV I was asking because I have the same problem... I’m just getting a new one lol.
@Jumpmaster3373 жыл бұрын
I sussed it. I changed the capacitor. Works now. Easy fix. Hope this helps.
@Jumpmaster3373 жыл бұрын
Oh. You already changed it sorry
@SloopyDog Жыл бұрын
My compressor starts fine after a few minutes of running it will stop and won't start again. If I then leave it for about 30 minutes it will start again. I suspect the pressure switch but I haven't changed it yet. Has anybody got any ideas? please.
@blackieswart76822 жыл бұрын
I have air coming out of the oil filler cap how do i fix that
@jamesv2811 Жыл бұрын
The plastic pressure line from the non return valve to the pressure switch is leaking where it goes into the pressure switch/reg body, how am I best to remove the line at this end?
@sealeytools Жыл бұрын
Hi. Please do give our Technical Team a quick call on 01284757505 or email them at technical@sealey.co.uk and they will be happy to get you back on track. Thanks.
@PetaniDKurt3 жыл бұрын
My compressor doesn't stop running. The pressure gauge only at 2 bar. unable to reach 8 bar to stop. I looked for leaking but i cannot find it since there's no leaking sound. What cause this issue usually?
@R4ZI3L6665 жыл бұрын
great video, if it is rebranding FINI SUPERTIGER VKM 4020-100-3M ?
@petermmachi12222 жыл бұрын
Helped a lot
@johnysilver18532 жыл бұрын
My compressor starts working and builds pressure up to 150psi but sometimes during work it will not start and won't keep tank charged. Sometimes it turns on only for a few seconds then goes quiet. Sometimes I hears something that it wants to start like air going somewhere through the pipe for about 2 second and then quiets and stays like that. Fails to keep up pressure in tank when I use it. Pressure goes low as 50psi but compressor doesn't start. Then I had to open drain valve to release remaining air pressure in the tank. Disconnect it from AC power for few minutes and it starts working again build up to 150psi again. I don't hear any air leaks. What could be wrong??
@roberto_assi_fcsi71693 жыл бұрын
Hi Great Finally Fixed Thank You!
@colassolorzano63536 жыл бұрын
Hello. .. my thermal overload switch. Wont let my compressor buid more then 50 psi. An til cold down... do you know where i can buy it. Par number is 17am-kp 145a0. Thanks.
@sealeytools6 жыл бұрын
Hello Colas, Is it a Sealey Compressor you have?
@otoniel7804 жыл бұрын
hi I have question my compresor runs good when is empti to fill up but when I use the air cam down and the compresor try to start the swich from my home or box switch shut down and the compresor have to empty to runs again thanks
@scottmarshall37402 жыл бұрын
This is the same for mine, did anyone get an answer to this fault?
@raakmore44434 жыл бұрын
My compressor is rated 125 psi but it only will build up to 98 PSI. Can you help me please?
@michaelparker-smith87733 жыл бұрын
Hello, my sealey SAE5030VE will not build much pressure and will continue to run. Initially I suspected head gasket. Momentarily after switching it off, I can hear air escaping from around one of the cylinder heads. Also the relief valve stays open presumably due to the compressor not building enough to close the valve? Any help?
@michaelparker-smith87733 жыл бұрын
Sorry, forgot to mention I replaced the relief valve with a bolt of the same thread to help me find the leak 👍
@michaelparker-smith87733 жыл бұрын
Okay, so the noise I was hearing was the breather hole in the oil filler
@sealeytools3 жыл бұрын
Hi Michael, firstly replace the pressure relief valve with some thread seal. Have you ensured the condensate value is tightened underneath the tank? If that is ok, it's most likely down to a valve plate in the cylinder head thats not closing which will prevent the compressor form building up pressure. If this is the case it will need to come back to Sealey to be repaired. Please contact our technical department on 01284 757505 to arrange this. Depending on the age of the compressor this will most likely be free of charge.
@michaelparker-smith87733 жыл бұрын
Ok, replaced PRV with some PTFE tape, and is now closing under pumping pressure, however tank pressure remains maximum 20psi. I would guess the flapper valves are knackered due to there being no evidence of ever having air filters fitted before I started my job here, where it's situated.
@DH-mf2lv4 жыл бұрын
I inherited my Dad's 2 HP 17 Liter air compressor. He used it for his nail gun. It never shuts off. Once the PSI gets to around 125 PSI, the relief valve opens and stays open until the psi reduces to 90 psi. At that time the relief valve closes and the pressure begins to rise til it gets back to 125 psi and then the relief valve opens again. Of course all this occurs while the nail gun is not being used. I sure wish my Dad was still here! Is this normal? I would appreciate a response. Thanks
@shamrockshore63083 жыл бұрын
+D H Did you ever get the problem of the lift valve opening on your compressor? If not, you should try adjusting the pressure switch to get the compressor to shut off at maybe 115 psi.
@johannamwailepeni69516 жыл бұрын
Amazing, great...
@calebwillhelm26355 жыл бұрын
I have a pos fini airattack. 1.5 horse power. Air was coming out of the air intake. Damn reeds were riveted into the valve plate. My question is can the high pressure reed cause air to come out the air intake. Im positive my low pressure reed is good but still have some air coming out the intake. This fini is a giant piece of crap. Cant even get them to email me back. Ridiculous
@ismailmohammed70584 жыл бұрын
My compressor won't turn off automatically how can I sort that out thanks
@shamrockshore63083 жыл бұрын
+Ismail Mohammed Adjust the differential limit on the pressure switch.
@zitothebubbleman9072 жыл бұрын
You may have a faulty capacitor.
@Derek-ul3wh6 жыл бұрын
I get my tank up to 120psi. When i begin to use any tool the performance drops radically. I decided to add a gauge right before my tool to see what was happening. Starting pressure of say a 90PSI tool will drop down 10 PSI every 5-10 seconds until it gets to say 50PSI and the tool becomes useless. I have checked for leaks, replaced fittings and used new hoses and cannot find anything. Could my pressure switch or regulator be the cause? what else could be causing this.(my tank is around a 15-20 Gallon)
@sealeytools6 жыл бұрын
Hi Derek,This could be caused by your tools needing a large amount of air ( CFM ) to function properly. This would result in the air in your tank being used very quickly. Typically, the compressor pump would start running to compensate for the loss of air very soon after starting to use the tool. The only solution to this would be to either buying a much compressor capable of running the tools you're using, or purchasing tools suitable for the size of compressor you own. I hope that makes sense?
@sealeytools6 жыл бұрын
Also, have you checked that any condensation in the tank has been drained off? we've had instances of compressors that haven't been drained containing gallons of water. This has the effect of massively reducing the air capacity of the thanksMatt
@ondrejsramek79873 жыл бұрын
My compresor 50 bar Made in home
@FastSlothVideos5 жыл бұрын
Mine sounds like a vacuum (Husky 4 gallon electric H1504st) and i cant figure it out.
@les1ed2 жыл бұрын
you are not answering the people here hope you are ok
@abdelatifsada7513 жыл бұрын
MIRSSI BOKO JESSUI AMAROC
@tonyv15055 жыл бұрын
leaking head gasket? are we talking about a compressor or a car lol
@smokenbudesq4 жыл бұрын
compressor
@iianduncan9867 жыл бұрын
is this the only person you ever use? Snore! Zzzzz
@Thetrucky696 жыл бұрын
There is nothing wrong with how this guy is talking in this upload. You probably snored through school Iian Duncan Zzzzz! Choose another post to troll on.
@nadinerafiq2666 ай бұрын
My compressor isn't building air is there a fix for that
@sealeytools6 ай бұрын
Good morning. Please could you get in touch with our Technical Team on 01284757505 or alternatively email technical@sealey.co.uk and they will be happy to look into it for you. Thank you.