Self Compacting Concrete | Free Flow| Civil Gyaan | High Dispersion admixture polymers |

  Рет қаралды 82,808

Civil Gyaan - All About Civil Engineering

Civil Gyaan - All About Civil Engineering

Күн бұрын

#selfcompactingconcrete #concrete #concretepumping #admixture #polymers

Пікірлер: 77
@nihal2459
@nihal2459 Жыл бұрын
Collapse slump?
@RAEFX0
@RAEFX0 6 ай бұрын
No bro it's self compacting concrete ❤
@AllkindofvideosIn1
@AllkindofvideosIn1 11 ай бұрын
How do you mix this concrete By Hand or Mixer?
@rupatul6034
@rupatul6034 Жыл бұрын
Can u explain we get flow in slump cone , there is any reference of IS if yes plz tell me for my pesnl knowledge bcz this is interview que for me
@THE-LIFE-78
@THE-LIFE-78 11 ай бұрын
As per IS 456:2000 Slump value of SELF COMPACTING concrete shoud not be less than 600mm.
@varunkumar41426
@varunkumar41426 10 ай бұрын
Might be 60mm..pls check again
@THE-LIFE-78
@THE-LIFE-78 10 ай бұрын
@@varunkumar41426 No, damn sure 600mm
@surajmalhotra4113
@surajmalhotra4113 6 ай бұрын
300 mm to height hi hota h ...600mm slump value kha se ayega
@raffekn1003
@raffekn1003 4 ай бұрын
No 600mm​@@varunkumar41426
@HarishKumar-jf5lm
@HarishKumar-jf5lm Жыл бұрын
This is slump cone to measure slump Flow ke liye alag dia and height hai cone ke liye
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 Жыл бұрын
Yes u r right... Bt both can be used for this test...
@navinkuka
@navinkuka 2 жыл бұрын
Flow table test hai ye generally lab pr kiya jata hai.. Or highly workable cct ke liye kiya jata hai
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 2 жыл бұрын
Yess.. Bt site pe concrete unloading se phle bhi test krte h.. Kyuki agar flow km rha to compaction achese nhi hoga jisse honeycombing aur surface finishing ka issue ho skta h... Isliye site pe bhi test krna mandatory h...
@vishnuprajapati3536
@vishnuprajapati3536 8 ай бұрын
Konsa chemical milate ho name hamko chahiy
@AllkindofvideosIn1
@AllkindofvideosIn1 11 ай бұрын
Can you tell me Mix proportion of that please
@shubhamkishor3464
@shubhamkishor3464 Жыл бұрын
How much dia covered?
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 Жыл бұрын
Its 750mm without bleeding.
@KNOWLEDGECARECS
@KNOWLEDGECARECS Жыл бұрын
Slump test is not suitable for such high workability concrete.......flow test is Obligatory... And the way he did the test represents his knowledge 🤣
@MukeshKumar-rt2ot
@MukeshKumar-rt2ot 6 ай бұрын
Workability achchi h lekin strength kam hogi .
@ravibata9850
@ravibata9850 2 жыл бұрын
Why the test is conduct for??
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 2 жыл бұрын
For example. If you have a conjusted reinforcement in structure where you couldn't initiate vibrator due to less gap between two bars.. Then this type of flow concrete is used... And minimum flow is required to fill the structure and before pouring concrete this test is conducted to get the actual flow of concrete... If it doesn't meet the minimum flow required we can do redosing with admixture and get desired flow... If we pour without flow test and doesn't meet the requirements may create honeycombing in structure and the structure may need to demolish.
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 2 жыл бұрын
There are more test which are conducted for self compacting concrete. This test is carried out for only self compacting concrete where we don't need to vibrate the concrete for compaction. It is self compacted with its own weight.... Please like and subscribe my channel... Work is going on for more content such as important of IS codes. Concrete mix design Admixtures MORTH etc
@ravibata9850
@ravibata9850 2 жыл бұрын
@@civilgyaan-allaboutcivilen361 any effect on strength of concrete??
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 2 жыл бұрын
@@ravibata9850 no effect because we need to considered all parameters while preparing mix design parameters such as w/c ratio. Min.cement content. Maximum size of aggregate. Flow required and retention required. Using high range PCE admixture etc... .. . . . I will post all civil related in this channel. Please do subscribe my channel.I will try to cover all facts and queries in civil.
@mohdamir7788
@mohdamir7788 Жыл бұрын
Slump is 30 Cm which is very higher 😅
@LiberFan-ft9pi
@LiberFan-ft9pi 5 ай бұрын
concrete admixture supplier ! !
@shaikbenazeerhidayathullah1991
@shaikbenazeerhidayathullah1991 Жыл бұрын
Can provide mix calculations
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 Жыл бұрын
Pls drop mail at allaboutcivilengg96@gmail.com Will revert in the same mail.
@AllkindofvideosIn1
@AllkindofvideosIn1 11 ай бұрын
​@@civilgyaan-allaboutcivilen361also Send me
@HarishKumar-jf5lm
@HarishKumar-jf5lm 2 жыл бұрын
Can you give design mix of thisi
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 2 жыл бұрын
Yess sure... Please mail me on allaboutcivilengg96@gmail.com
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 2 жыл бұрын
Sent
@KallemBhavyashri
@KallemBhavyashri Жыл бұрын
Can you share me the mix design details
@KallemBhavyashri
@KallemBhavyashri Жыл бұрын
Can you provide me the mix calculations
@AllkindofvideosIn1
@AllkindofvideosIn1 11 ай бұрын
Same Question
@Civilengineers3
@Civilengineers3 6 ай бұрын
Badiya hai
@opoaxacan7091
@opoaxacan7091 8 ай бұрын
WAP
@ashwanikumar-yu7ge
@ashwanikumar-yu7ge 2 жыл бұрын
Test me apparatus hi ulta pkd rkha h
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 2 жыл бұрын
Hiii Flow test aise hi hota h... Jb slump test hota h to isko sidha pkdte h... Iska aur ek apparatus hota h jiska height isse km hota h
@palak6513
@palak6513 2 жыл бұрын
@@civilgyaan-allaboutcivilen361 kuch bi 🙂
@SomnathMondal_
@SomnathMondal_ Жыл бұрын
​@@palak6513 yes its true SCC concrete ke flowability aise h measure hota hain.
@civilgurusid1302
@civilgurusid1302 11 ай бұрын
​@@civilgyaan-allaboutcivilen361read IS 1199 carefully bro
@civilgurusid1302
@civilgurusid1302 11 ай бұрын
Aap slump cone abhi bhi 4 layers me hi bharte honge 😂
@Sohaib24434
@Sohaib24434 2 ай бұрын
To kitne layer me bharte hai sir
@harryboomboy1409
@harryboomboy1409 3 ай бұрын
Bit to much water in that one mate
@katilkrishna143
@katilkrishna143 5 ай бұрын
Flow box ulta kyon pakde Ho 😅
@RahulYadav-fs1ps
@RahulYadav-fs1ps 8 ай бұрын
Collesp h 670 flow
@dondiego4966
@dondiego4966 2 жыл бұрын
Я тоже так могу, когда молоко попью
@lawacooking5273
@lawacooking5273 Жыл бұрын
C.
@NMUk87
@NMUk87 Жыл бұрын
WORNG WAY
@brajeshverma3296
@brajeshverma3296 4 ай бұрын
Due toh high sagregation
@mukeshbhagat2498
@mukeshbhagat2498 2 жыл бұрын
Slump Greater than 150
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 2 жыл бұрын
Hii Mukesh... Slump test is different and flow test is different. Slump greater than 150mm comes in collapse slump category...
@talatmahmoodkhan1342
@talatmahmoodkhan1342 Жыл бұрын
​@@civilgyaan-allaboutcivilen361and collapse of slump leads to segregation and bleeding problems
@Abdu4548
@Abdu4548 9 ай бұрын
Concrete is bleeding
@belalmallick97
@belalmallick97 Жыл бұрын
Little bleeding
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 Жыл бұрын
It is not considerable... Passed v funnel in 13seconds
@civilgurusid1302
@civilgurusid1302 Жыл бұрын
But this is not the actual way to conduct this test
@kstorm889
@kstorm889 11 ай бұрын
Not the actual way to conduct a flow table test? How so?
@civilgurusid1302
@civilgurusid1302 11 ай бұрын
Read 1199 carefully bro This test actually performed on Flow table and the test where you performed is not a flow table and it's also not performed by taken reverse of slump cone
@Chinoiserie9839
@Chinoiserie9839 11 ай бұрын
Thats not how you do a slump test.
@steventhompson6
@steventhompson6 11 ай бұрын
Good thing that’s not a slump test
@commandostudy301
@commandostudy301 2 жыл бұрын
Concrete fell
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 2 жыл бұрын
No... We measured flow of concrete... Its around 780mm diameter
@poornanandverma1927
@poornanandverma1927 Жыл бұрын
Collapse
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 Жыл бұрын
Yes... But it is flow concrete....
@aadityaverma326
@aadityaverma326 Жыл бұрын
More Water cement ratio Collapse karega
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 Жыл бұрын
Slump me dekhoge to collapse hi rhega...more than 250mm ka slump
@aadityaverma326
@aadityaverma326 Жыл бұрын
@@civilgyaan-allaboutcivilen361 mine bhi bola collapses karega
@Rajguru-w8n
@Rajguru-w8n 9 ай бұрын
Ye galat hai
@mrhatela1900
@mrhatela1900 Жыл бұрын
ye slump test hai lakin ye ulta Kiya hai
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 Жыл бұрын
Hii.. Yeah slump test nhi h... Flow test h... Isko hm uske diameter se measure krte h...
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 Жыл бұрын
Jaha reinforcement dense hota... Jaha normal needle vibration possible nhi hota h... Waha yeah is tarah ka concrete self compacting concrete use hota h...
@choudharyankit4176
@choudharyankit4176 Жыл бұрын
W : C : R kitana hai
@civilgyaan-allaboutcivilen361
@civilgyaan-allaboutcivilen361 Жыл бұрын
0.22
@mohdamir7788
@mohdamir7788 Жыл бұрын
Wrong 😂
Миллионер | 1 - серия
34:31
Million Show
Рет қаралды 2,6 МЛН
Life hack 😂 Watermelon magic box! #shorts by Leisi Crazy
00:17
Leisi Crazy
Рет қаралды 78 МЛН
小蚂蚁会选到什么呢!#火影忍者 #佐助 #家庭
00:47
火影忍者一家
Рет қаралды 71 МЛН
How to build multi-storied structures using stabilised mud blocks
8:58
Deccan Herald
Рет қаралды 1,4 МЛН
The Differences Between Plaster, Mortar & Concrete Mixes
3:06
BuildersSA
Рет қаралды 191 М.
Underwater Constructions | How do Engineers Make Them?
9:16
Sabins Civil Engineering
Рет қаралды 9 МЛН
TEST FOR WORKABILITY OF CONCRETE - SLUMP CONE
3:51
UltraTech Cement
Рет қаралды 1,4 МЛН
Could this LEGO Plastic Brick replace Concrete Masonry Units?
12:25
Belinda Carr
Рет қаралды 1,5 МЛН
Does Rebar Rust?
7:49
Practical Engineering
Рет қаралды 4,6 МЛН
Slump Flow Test- SCC Concrete
2:40
CONCRETE TESTING Channel
Рет қаралды 53 М.
Superplasticizers: the wonder of fluid concrete
3:57
Lafarge
Рет қаралды 187 М.
Миллионер | 1 - серия
34:31
Million Show
Рет қаралды 2,6 МЛН