HI. You were very helpful. Especially when explaining fw settings. thank you me how
@sudhindrasukumar2605
@sudhindrasukumar2605 Жыл бұрын
Hi, thank you for the demonstration. Is it possible to go on without installing sql express, and by using the instance generated by wincc?
@AutomationStation
@AutomationStation Жыл бұрын
Should be, just be careful when it comes to T's&C's as I think there might be some restrictions when it comes to what you can use the wincc's SQL server for
@juancarlosespinosajimenez8704
@juancarlosespinosajimenez8704 3 жыл бұрын
Hello, could you share a video an explain how to do query since s7-1200 to MSSQL, please?
@Yosuke94
@Yosuke94 2 жыл бұрын
Due to connect PLCSIM Advanced (Ethernet adapter) instance to SQL server, they HAVE TO be on different stations (PLC SIM on my laptop and SQL server on VM)?
@AutomationStation
@AutomationStation 2 жыл бұрын
They don't have to be, if they are on the same station you'd be hitting localhost on 127.0.0.1 rather than another machine.
@binor2286
@binor2286 Жыл бұрын
Guys I got an interesting error , so when I enable the SQL. The code turn to 7002 which is completely normal but after 17s (yes I'd count and each time it's 17sec) it turns to the error code 8602, sub function status 80C6 in state 3 . Does anyone had an idea on how to fix this problem ?
@rolandbailly7078
@rolandbailly7078 3 жыл бұрын
Hello, thanks for your video ! I would like to send data from my plc to my ms sql. I am using a VPN to contact my PLC. Is there a specific configuration to apply?
@AutomationStation
@AutomationStation 3 жыл бұрын
Not really. As long as your VPN is set correctly the rest stays the same. You might need to use the VPN address of your server though
@jonathanlagar6926
@jonathanlagar6926 Жыл бұрын
How can i get the service authentication username and password
@曾亮中
@曾亮中 4 жыл бұрын
S7-1500 Example 'insert into PLCDATA values (5,6,7)' If it's in the s7-1500 DB way, how to write
@AutomationStation
@AutomationStation 4 жыл бұрын
Hi! Check our other video that shows you how to actually write any data from your S7-1500 PLC to your SQL Databse: kzbin.info/www/bejne/baapm5l_l5eZjqc
@alejandrojosegutierrezrodr1767
@alejandrojosegutierrezrodr1767 3 жыл бұрын
Has anyone tried to get it to work with the simulator? it's possible?
@lamsonlemai6516
@lamsonlemai6516 4 жыл бұрын
Sorry, I always received Error 8602- subfunction status 80C6. I tried to config again My SQL server and used PLC Sim Advance 2.0 to replace for PLC Simadvance 3.0 but It can't working. I will try to use hardware S7-1200 for project example. Thanks you
@AutomationStation
@AutomationStation 4 жыл бұрын
I'm afraid this will not work with My SQL, you'd need Microsoft SQL
@lamsonlemai6516
@lamsonlemai6516 4 жыл бұрын
It is my fault, I am using ms sql server with both plc simadvance and plc s7-1200 But I always have error 80C6
@AutomationStation
@AutomationStation 4 жыл бұрын
@@lamsonlemai6516 And have you tried accessing the DB with Server Management Studio? Does it work for you?
@lamsonlemai6516
@lamsonlemai6516 4 жыл бұрын
@@AutomationStation yup, it 's okay when I login user and try excute query statement. With PLC I 've checked but Port 1433 ( or other ports that setup for SQL) haven't worked. Next I will use wireshark to check connection between PLC and SQL server
@lamsonlemai6516
@lamsonlemai6516 4 жыл бұрын
Hi, I Can Access my database from other PC in Lan network and I saw they tranfer data through port TCP 1433 so I suppose that an error occurs when statement TCON begin in PLC
She's very CREATIVE💡💦 #camping #survival #bushcraft #outdoors #lifehack
00:26
Как мы играем в игры 😂
00:20
МЯТНАЯ ФАНТА
Рет қаралды 3,4 МЛН
Officer Rabbit is so bad. He made Luffy deaf. #funny #supersiblings #comedy
00:18
Funny superhero siblings
Рет қаралды 17 МЛН
Kluster Duo #настольныеигры #boardgames #игры #games #настолки #настольные_игры
00:47
COM13d. [4/5]V20 Connecting a Siemens PLC S7-1500 to an SQL Database [PLC Section]
27:10
Electrical Automation Hands-On
Рет қаралды 7 М.
How to connect a Siemens S7 1200 PLC to a SQL Server Database
14:56
SQL4automation
Рет қаралды 74 М.
(Analog signals)How to program an analog (input/output) and simulate it on TIA portal (S7-1200)PLC
8:56
B Electric "How to automation tutorials"
Рет қаралды 13 М.
you need to learn SQL RIGHT NOW!! (SQL Tutorial for Beginners)
24:25
NetworkChuck
Рет қаралды 1,5 МЛН
Learn Microsoft Active Directory (ADDS) in 30mins
36:26
Andy Malone MVP
Рет қаралды 917 М.
She's very CREATIVE💡💦 #camping #survival #bushcraft #outdoors #lifehack
00:26