I have to say that of all the youtube providers specializing in Home Automation, your channel is consistently the most informative. I always learn something. Keep up the good work!
@digiblurDIY10 ай бұрын
Thanks! I always try to teach something in various videos when I can with various products.
@matejfoltyn10 ай бұрын
I already have the 1-mini installed behind a light switch and it works like a charm! Really happy with the smaller size and even the price is so reasonable!!!
@MarkEichin10 ай бұрын
You're right, if they could make a compact plug with the power monitor unit, I would scatter them about the house, and keep a few extras around for friends to dip their toe in to power monitoring - or just to help them get real numbers on parasitic power without having to leave a (functional-but-)ugly kill-a-watt around. The low-current units might be suitable for lighting-only runs, there was apparently a recent update to the US NEC for lines with 10A breakers [and no outlets, only direct connections.] That's pretty niche and I'm not sure anyone's started doing it in the wild yet :-)
@digiblurDIY10 ай бұрын
Yup, I saw that update. Too bad these are 10A. I heard the update still requires 14 AWG though and the 10A breakers are expensive.
@FrankGraffagnino10 ай бұрын
great review. I like that shelly makes those header pins accessible on some of their units but we need it on all of them! We need more hardware we can control locally!
@digiblurDIY10 ай бұрын
Yes, I was sad to see the little header gone. I'll be sticking to the plus 1 lines myself as they are more amps anyways.
@WilliamCasolare10 ай бұрын
Excited for when they get the new ones UL listed. Until then will be sticking with the not UL, not inside my walls approach.
@digiblurDIY10 ай бұрын
I don't think they would pass with the 8A rating.
@YKSGuy10 ай бұрын
According to the Shelly reddit there is no work or plans to get the minis UL certified at this time.
@WilliamCasolare10 ай бұрын
@@YKSGuy oof - that is a huge L for me. It is one thing to put non-UL devices in play outside the wall but putting them in-chain with code regulated wiring is a nonstarter for me. Insurance companies get nice and iffy when these rules get broken.
@digiblurDIY10 ай бұрын
@WilliamCasolare what area are you in? US here and I spoke with local insurance agents before and they said they don't even look at UL stuff anymore on the residential side. It is hard enough for them to prove in court on other intentional fires as it is.
@WilliamCasolare10 ай бұрын
@@digiblurDIY Northeast US - all national homeowners insurance companies still have the requirement listed and if an inspector decides to point at an unlisted device as the cause they can choose to deny the claim. Regardless of what an agent or customer service rep or whatnot might say, it's still on their terms and conditions and that increases the risk profile too high for my liking. If they're going to ignore it in practice, which they very well might be doing, they should officially remove it from their T&C's.
@justmeEnglandUK10 ай бұрын
How about a update on the breaker board energy monitoring any new products available for multiple breaker feeds
@terryuland650210 ай бұрын
I built a ESP32 based device to monitor current to my aerobic septic system using current transformers, and this certainly would have been handy to have, but I am very concerned about the lack of accuracy. The hz output is just broken, even a cheap kill-a-watt clone can get that down to 0.01 accuracy. It would be nice to compare those voltage and amp readings against a couple of Fluke meters and see how close they are, and see how much it differs across different devices of the same model. TP-Link Kasa has a current monitoring smart plug which easily integrates into HA, but it too has accuracy issues -- I can have two plugs right next to each other and one reports 118v and the other 121v. Finally, how stable are these devices on dirty power? Imagine you have a decade old generator hooked up chugging along with it's massive voltage sags when things kick on. Will it "freak out" the readings like you observed with over current?
@MarkEichin10 ай бұрын
Maybe look at that UPS output with a scope? I've seen a lot of weird signals even from "true sine wave" UPSes, let alone the bad-old-trapezoid-days...
@petenachtigall1224Ай бұрын
My Shelly PM was reading the same for the frequency (41 Hz) when I first installed it. the latest firmware update fixed that.
@digiblurDIYАй бұрын
Yup. Glad to see they fixed this!
@jefffrilot966710 ай бұрын
I've been wanting this for a while, a simple power monitor. I've gone through several plugs where the relay eventually died. Most were killed by summer brownouts. A simple plug where I don't have to remove the receptacle would be nice though.
@digiblurDIY10 ай бұрын
They could have done a NC relay instead of NO but the simplicity of it is nice. Hopefully we see more from others as well.
@stufq10 ай бұрын
So if relay is dead why not remove relay, "Hardwire" it remove relay from firmware and use it as power monitor only?
@jefffrilot966710 ай бұрын
@@stufq these were cheap not easily disassembled plugs flashed with tasmota using tuyacutter.
@ivlis3210 ай бұрын
I played around with the stock firmware for a bit, spent 30 minutes trying to figure out which ports I need to open in order for HA integration to work, but still couldn't. Gave up and flashed Tasmota on it. The process is super easy. Unfortunately it's not possible to OTA esphome because they use different boot mechanisms. Another drawback of the stock firmware is that it sends updates every 15 seconds and it's impossible to send an update when consumption suddenly changes.
@chrislambe40010 ай бұрын
Shelly relays beats everything on size every time. In Europe we don't have those giant wallboxes like in North America. Compactness really plays a role here. Sonoff ZBMINI or Aqara T1 or Moes are all so huge compared to Shelly. So big that I am having a little trouble extending a Zigbee mesh across three floors of my home. I really have to think where can the two Zigbee relays I want per floor actually fit. Might just install some of them with no switch or load connected in the ceiling. One of my Shelly Mini Gen3 handles 15 BLE thermometer/humidity (LYWSD03MMC Xiaomi) without breaking a sweat.
@digiblurDIY10 ай бұрын
And here I am thinking our boxes are small. I have been swapping several of mine to deeper boxes and/or jumping up a gang to help with the fill ratios and ease of things.
@djvincon9 ай бұрын
How do you use it with the BLE meters?
@RiccardoAzzolinoАй бұрын
Have the grey (in my breaker Line) and red one (as switch and power meter) in my home Assistant system 👍 Zend back the blue one cause NO power metering 😢 Auto update via HA love it.
@digiblurDIYАй бұрын
Yep, blue is just the plain relay one. It is good for dry contact usage though.
@anlpereira10 ай бұрын
There is a way to calibrate the current and frequency through YAML. Look in the ESPHome documentations. I'm developing a board like this for me. Great video
@digiblurDIY10 ай бұрын
I mentioned yes with open source you can change the calibrations, I was showing the stock firmware.
@anlpereira10 ай бұрын
@@digiblurDIY great video. Thank you very much
@realitydog864010 ай бұрын
Makes me wonder about sizing shelly devices when connecting them to motorized appliances. There is a difference between running amps and locked rotor amps. Will frequent starts break down the shelly relay?
@dream4magi10 ай бұрын
The power differs between shelly and the plug type meter maybe due to power factor calculation. The plug type power meter has ability to calculate the power factor therefore showing the real power. The Shelly shows the apparent power only.
@digiblurDIY10 ай бұрын
It wasn't a big difference, no massive faults there. The only thing odd was the Hz. It wouldn't show up as 60hz on the inverter or even mains AC.
@dream4magi10 ай бұрын
@@digiblurDIY There will be big difference measuring different kind of loads. I once measure a notebook adapter and got a power factor of 0.5 .
@joshbean3910 ай бұрын
3:55 if thats the case, if you're running 20A circuits to everywhere then I guess no smart plugs or regular shelly's? Or normal single pole 15A switches, I don't see it as an issue tbh considering I'm only switching low current loads with them.
@digiblurDIY10 ай бұрын
Most of mine are 15A circuits so 16A is perfect. Keeps the weakest link at the breaker.
@chrislambe40010 ай бұрын
In the case of socket power outlets you have to consider what maximun loud could somebody cause by plugging in something else. I don't have any such sockets. Conisder marking the sockets with the Max load.Maybe your eletrical code allows installing lower Ampere breakers. I do have plenty of lights where the load is always going to be rather tiny and have no worries installing 8A Shelly Minis for that.
@ronm658510 ай бұрын
Pretty cool. Thanks Travis.
@digiblurDIY10 ай бұрын
You bet
@RiggerBrew10 ай бұрын
I agree, 16a switching is what I'd feel good about. Think I will get the PowerMonitor and add it to a few plugs as I need to start tracking power usage for my small farm business.
@digiblurDIY10 ай бұрын
Yup... the weak link issue there.
@algis32077 күн бұрын
Hello! Thank you for sharing your experience and helping others! Please tell me, is it possible to set the app to turn on for 2-3 seconds, then turn off for 20 minutes and so on, endlessly cyclic operation?
@digiblurDIY4 күн бұрын
Probably something you would need to handle in the device scripting in their firmware.
@ecoheliguyАй бұрын
Not only behind a receptacle, you could install these inside the appliance.
@digiblurDIYАй бұрын
Kind of like we did with the CT clamps on dryers.
@ecoheliguyАй бұрын
@@digiblurDIY and were the 8amp limitations of the relays can be really useful in North American markets. Like range hoods and other fans.
@oscargravelandАй бұрын
@@ecoheliguy You read my mind. Mine is inside a floor fan. It let's HA control ON/OFF and fanspeed setting over IR remote ( Shelly works as the feedback)
@Saturn2888Ай бұрын
It says 8A at 240V which is more than enough power for a standard 15A 120V outlet. The 30V is different because it's DC, not AC.
@Saturn2888Ай бұрын
The one that's 16A with no relay is insane. Close to 4000W of power you can push through it? That's more than my 20A outlets!
@oscargravelandАй бұрын
Don't think it works that way. 8A limit is still an 8A limit on 120V outlet.
@danielarchers26658 күн бұрын
@@oscargravelandit does
@jmr10 ай бұрын
I'd be interested in a version of the power monitoring plug I could use on a dryer.
@digiblurDIY10 ай бұрын
Exactly! I know not everyone wants to do CT clamps, etc, 240v split phase stuff freaks people out which it should. Give them something they just plug in between the wall and dryer with the open Shelly firmware? Boom! Sold
@Corgitronics10 ай бұрын
The PM Mini Gen3 doesn't appear to have any safety certifications at all. Maybe I'll wait for that.
@dcj204515 сағат бұрын
I will be installing a 200 W LED lights outside. Will this support that? Or is 200 W too high for it?
@digiblurDIY15 сағат бұрын
Probably fine being well under the amperage
@kingskawn3 ай бұрын
When those things use the wifi, is it better to create a separated wifi SSID and IP range only for the smart devices/relays ?
@digiblurDIY3 ай бұрын
That's what I do as it makes things easier to cut then from internet access, make plain Jane 2.4ghz ssids etc.
@looper61206 ай бұрын
I also experience the issue, wattage is not accurate at all... same issue with Shelly plug plus
@gregpadberg140210 ай бұрын
Electric clothes dryer is on 30A circuit at 240V so no bueno there, oh well. Would be OK to monitor the clothes washing machine on a regular 15A circuit at 120V though.
@digiblurDIY10 ай бұрын
Same here. 240V30A is used for electric dryers here. I wasn't sure what was used in non split phase markets.
@AtracBreezy10 ай бұрын
Can skip all of this and flash an Emporia Vue 2 and just CT clamp everything at the breaker. That’s probably best for appliances.
@digiblurDIY10 ай бұрын
I know a guy who showed it once or twice 😎 awesome setup. Love mine.
@unclerojelio63207 ай бұрын
I guess you could put one on each phase and then have HA add them together. Still, I’d rather have a plug version and I’d like to see them certified.
@BillyJoeBob36917 ай бұрын
Just use a 2 pole contactor rated for more than what the dryer is, wire the relay up to the coil in series, and boom you’re done.
@AceBoy2099Ай бұрын
Can you set these as an "intake only" (L and N terminals only) to be able to use for power monitoring (I have a set of the blue 1 mini models) I just want to have it report on or not (for storm power status, Wired so it will report service power while on generator power).
@digiblurDIYАй бұрын
You could see if the device is online basically and go by that for power state.
@TomNouri5 ай бұрын
I ordered the blue one and was going to use it with my RV AC. I had not payed attention to the amps and looks like that’s not going to work. Will have to send it back. I do have the AC temporarily open and connected to a smart plug and that’s been working great. Was hoping for something I can also control via Bluetooth when no wifi is available. And suggestions?
@digiblurDIY5 ай бұрын
I don't know of any bluetooth ones.
@Morgon4 ай бұрын
This may be a stupid question, as I'm not much of an electrician, but I have never seen this explicitly discussed anywhere -- is there a way to get individual outlet monitoring on each plug of a two-outlet receptacle..?
@digiblurDIY4 ай бұрын
US market?
@Morgon4 ай бұрын
@@digiblurDIY Yes, apologies for not specifying.
@digiblurDIY4 ай бұрын
@Morgon use a Shelly 2 and split that little pop off between the two screws.
@Morgon4 ай бұрын
@@digiblurDIY Thanks! On both sides, or just the hot? I haven’t seen any YT videos on installing a Shelly 2 with an outlet in this way… don’t suppose you have one that I just couldn’t find via search?
@digiblurDIY4 ай бұрын
@Morgon just the hot side. Neutral is fine as is. I did one like this but didn't video it.
@vegatube38189 ай бұрын
Nice Travis, what is the benefit of Tasmota? And how do you go from Tasmota to esphome?
@digiblurDIY9 ай бұрын
Being able to adjust an necessary calibrations, using matter if you want that, and several other things that open source firmware brings. I haven't used this one but I know some that have on other ESP32 conversions - github.com/esphome/esphome/pull/5535
@ggeimer6 ай бұрын
can this monitor voltage since it can’t handle the 50 A that I need for my air conditioner condenser? I would like to monitor the voltage of my air conditioning unit I have two issues. The power company can cycle it and the second one is I have GFCI and sometimes that trips the issue with this is when either condition occurs my air conditioner fan runs constantly circulating ambient air. I would like to automate my Nest to shut off the AC fan when power is off on my condenser. I don’t know why HVAC doesn’t monitor that because I would argue that running the fan at high-speed 24 seven uses a lot more power than cycling, the air conditioner in a normal operation. I would also like to be alerted when my GFCI breaker is open so that I know to reset it so that the air conditioner can function normally. I have automation using Google and Alexa to shut off my pool pump when the air conditioner unit is on and turn it back on again when the air conditioner cycles off, but I would also like to make sure that I just save power in general and not just run my fan pointlessly.
@digiblurDIY6 ай бұрын
It can but if voltage drops then of course it is offline. You could read it the status of it being offline to determine this.
@K-politic10 ай бұрын
100% agree here. I do not know why they make in wall units under 15 amp. There are other uses but not in wall
@digiblurDIY10 ай бұрын
There are new NEC rules that will allow for 10A Lighting breakers but that's still short 2A.
@digiblurDIY10 ай бұрын
That's not how that works. You don't get 32 amps going on. You could take 4 15amp switches on a 15amp rated wires, 15amp breaker, etc, you'd still only have a 15 amp circuit and not 60 amps. Just like how you can have well over 200 amps of breakers in a 200A panel.
@K-politic10 ай бұрын
@@digiblurDIY I am aware of the NEC rules but I still do not like the fact that you have to be aware that a plug can not draw the full 15 amps because of a unit in a wall that could get overloaded. you may know because you installed it but could forget or someone come behind you and use the plug for a high draw item and fire.
@tstrenuous108 ай бұрын
Just to dig up an old argument……@digiblurdiy you’re saying I shouldn’t use an 8 amp relay to control 6 amps of electricity because the breaker is rated for 15 amps, and I might forget I have an 8 amp relay in the wall which could result in me putting more powerful appliances in line and overloading the 8 amp relay, correct? I’m pretty sure the 8 amp mini relay is for folks who can add up the amperage of the lights they’re controlling and not confuse the outlet for their deep freezer or dryer for they light switch for the porch lights.
@digiblurDIY8 ай бұрын
@tstrenuous10 that's not how it works at least in US electrical code. Not an argument at all. I can't just say oh I will never put more than a couple LED lights on this wire and use 18 awg wire and throw a 20 amp breaker on it.
@t0mz3n7510 ай бұрын
I am using a Shelly plus 1 AS a Garage door Opener with tasmota based on one of your old Videos. I would be nice to See a Video based on esphome.
@digiblurDIY10 ай бұрын
Yeah.. Those are a little easier to do with Esphome now for sure. These minis are difficult for some to swap over from stock though. Let me see what I can come up with.
@alexsinbb10 ай бұрын
What will fail are the capacitors, like every Shelly 2.5 I have owned.
@digiblurDIY10 ай бұрын
I have a 2.5 outdoors in box right now. Still kicking along luckily but I have seen the pictures on their FB group of the failures.
@alexsinbb10 ай бұрын
@@digiblurDIYprobably a bad batch with the ChongX capacitors.
@chrislambe40010 ай бұрын
@@alexsinbb Thanks for the tip. I have 12 Shelly 2.5 I bought several years ago. 11 of them are sitting on my desk now. Edit: The ChongX Cap is the single horizontal 16v 100u might have to bend it up to see the ChongX branding on it. I might just replace them all with panasonics EEUFR1C101.
@oakfig10 ай бұрын
Bruh, this is exactly what I been wanting! Is there a limit to how many of these we can set up?
@digiblurDIY10 ай бұрын
Probably not unless you wifi is just overwhelmed but there are ways to fix that.
@CraigMullins110 ай бұрын
3:30 - hmm if it takes 8 amps at 240 volts it would take 16 amps at 120 volts. Unless my math is wrong? :)
@dream4magi10 ай бұрын
What really matter is current.
@digiblurDIY10 ай бұрын
You are thinking watts there. Amps X Volts = Watts
@terryuland650210 ай бұрын
I used to think that as well, but the limiting factors of amperage are the size of the conductors and how hot parts next to them can get (insulation on wire, connectors, plastic housing, etc). The limitation of voltage is the amount and type of insulation between conductors (including air). So you think of each rating as a maximum, and in this case, you can have 0-8 amps and 0-240 volts. Going over on either amps or volts puts you out of spec. This is why, generally speaking, you want to always use the highest voltage possible. In this example, 8 amps at 240 volts is 1,920 watts of power, whereas, if you dial the voltage down to 120, it can only handle 960 watts of power.
@CamiloSperberg10 ай бұрын
I'm thinking the same, it also explicitly states 8A @ 240v or 2000W, which would double the amount of what you get with 120v... but on the other side, the US is the only weird country in the world to use an unconventional electricity voltage, so maybe they should just switch over to 240v like the rest of the world and get over it. I do know that it allowed me to finally automate my kitchens' lights (now that it is small enough to fit) which uses 24W of power in total :)
@digiblurDIY10 ай бұрын
@CamiloSperberg lol.. We can't even get rid of DST to this day.
@djashjones10 ай бұрын
5% accuracy by my calc's. Whether that's acceptable, that's a different story.
@e74av10 ай бұрын
Everything is amazing but wi-fi signal. It's miserable for minis and gen3.
@kanehysop25914 ай бұрын
shelly pro 3em
@digiblurDIY4 ай бұрын
No dinrail setup here.
@tomferrin11484 ай бұрын
Dude, just wire up the 16A PMG3 in the middle of a short 3-wire extension cord instead of complaining about the product.
@digiblurDIY4 ай бұрын
Huh? The 16A gray mini product is great. Such an awesome idea.