bhai, i have watched almost all videos and your technicality is very great and everyone can understand the simple language. ese hi pdhateraho . me bhi solar company chalatahu. design and consulting ka. or abtak bohot logoko tmhara video share karchukahu..... thank you for all the videos😃
@solarfacts4242 Жыл бұрын
Thank you so much 😊
@ajeet.singh8002 жыл бұрын
Very useful vidio Raman jee
@solarfacts42422 жыл бұрын
Thanks sir
@ramdhaniyadav23382 жыл бұрын
Really, very information video... Thank you so much making such types of platform. 🙏🙏🙏🙏
@solarfacts42422 жыл бұрын
Thanks 🙏
@siddhantsingh47982 жыл бұрын
Well explained ,it’s help me lot during my job.
@solarfacts42422 жыл бұрын
Thanks 🙏
@sourabhsharma99852 жыл бұрын
Very informative vedio
@solarfacts42422 жыл бұрын
Thank you
@khaleelullahmohammed47134 ай бұрын
Very clear explanation
@surendrakverma555 Жыл бұрын
Very good. Thanks 🙏
@umerfazalkhan80952 жыл бұрын
Great Teacher
@solarfacts42422 жыл бұрын
thank you
@vijaytwites7663 ай бұрын
Thank you sir but please explain what is the 1.05 its voltage Variation factor...?
@prabhjotkaur1575Ай бұрын
Sir please mention the standard from which this cal. Has been taken
@ramdhaniyadav23382 жыл бұрын
Well Explained Sir!! Please make an Video Transformer Fault Current Vs Electrical System Fault Current ( Which Fault Current is Greater) and How Calculate Earth Strip Size due to this fault current for Electrical Earthing System. Thanking You Ram Dhani
@solarfacts42422 жыл бұрын
Ok Sure
@electricalconcept819611 күн бұрын
What is num of run ?
@badshahsamir650511 ай бұрын
12:12 par nom . Of run 5 liya he ap ne Nom. Of run 5 q liya ?
@solarworldmirzapurup33782 жыл бұрын
Sir, plz make video to calculate current carrying capacity of wire
@solarfacts42422 жыл бұрын
Ok Sure noted your topic 👍
@sudhirsharma3435 Жыл бұрын
on LV side of transformer at point A you can simply find the fault current by dividing the phase current by %Z, i.e assuming 415V side is star connected and so line and phase current will be same, I ph= 1000/(sqrt(3) x 0.415) = 1391.205A and then divide this by %Z i.e 1391.205/0.06 = 23.186 kamps is the short circuit current and 105% voltage it will be 23.186kA x 1.05 24.35kA. Actually no need to find the impedance in ohm and that the transformer LV side impedance when you specify in ohm, when you specify in %Z then only its t/F impedance irrespective of LV and HV. Can you explain what is mean by 5 run cable, I assume on 415Volt side you have 3 bushing and each bushing have at least 1 cable , then how you counted them as 5 run. Are you taking 5run/phase
@nimeshmandal7606 Жыл бұрын
May he have taken 5 run per phase since current is very more
@solarfacts4242 Жыл бұрын
Ok thanks for input
@mohammedirzath2788Ай бұрын
agreed, but as per his formula without calculating impedance of tx in ohms how can we find the short circuit of next point pls explain
@saifsyedmohammad3769 Жыл бұрын
Can we connect 15 panels with 10A Isc with 1 panel of 13A Isc in series any damage expected here ?
@solarfacts4242 Жыл бұрын
You can but your 13 A panel output will work as a 10 A Panel because of series connection.
@qissakahanian1315 Жыл бұрын
What is no. Of runs
@electricalknowledge69512 жыл бұрын
👍
@solarfacts42422 жыл бұрын
thanks
@NIRAJ80192 жыл бұрын
Pls reply me sir enphase micro inverter i q 7 plus sir 390 w ka panal lagna per one day ma ketna unit produce kar tha hai sir ager 1 kw ma system install ho to ketna unit generate ho ga or panal bi fical 390 w ka 3 panal ho sir pls reply me
@solarfacts42422 жыл бұрын
Per KW generation will depend on plant installation if plant is installed in a correct way than this will generate approx. 4.5 Unit
@vikasdhiman59609 ай бұрын
❤❤🎉🎉
@soumya22212 жыл бұрын
Motor ka fault current kaise nikale
@solarfacts42422 жыл бұрын
ok Noted we will make one video on it :)
@bappadityabarman76782 жыл бұрын
Sir 1.05 kaha se aya.... derivation ho toh achha hota
@solarfacts42422 жыл бұрын
ok i will make with explanation
@prateikgan43098 ай бұрын
105% voltage @bappadityabarman7678
@soumya22212 жыл бұрын
Sir 1.05 multiply kyun kiya gaya
@solarfacts42422 жыл бұрын
this 1.05 is in formula only :)
@prateikgan43098 ай бұрын
Incorrect 1.05 cames from 105% voltage applied in primary at which we achieved full load current at secondary @solarfacts4242
@shirsendudas42102 ай бұрын
Pagal kya bta raha😅😅
@solarfacts42422 ай бұрын
Pagla kue sun raha mat sun 😂😂🤣🤣
@NIRAJ80192 жыл бұрын
Pls reply me sir enphase micro inverter i q 7 plus sir 390 w ka panal lagna per one day ma ketna unit produce kar tha hai sir ager 1 kw ma system install ho to ketna unit generate ho ga or panal bi fical 390 w ka 3 panal ho sir pls reply me