SHOULD YOU FIT IP65 CONSUMER UNITS OUTSIDE?

  Рет қаралды 1,907

NAVITAS

NAVITAS

Күн бұрын

Пікірлер: 28
@navitascp
@navitascp Жыл бұрын
Watch our video on thermal derating here kzbin.info/www/bejne/rneqioqMnNOfl5Y
@electrician247
@electrician247 Жыл бұрын
Thanks for the kind words Will. I would have placed me more as the old waffling spark on YT lol. Great video and echo your views. Adams question is a good one. On large scale EVSE they all have heaters for this. Smaller 7kW and 22kW charge points generally have the electronic RCD varieties which are to a different product standard than 61008 61009 60898 etc. The ones with the traditional RCCBs inside them will require thermal effect consideration and that is on us as installers to select the product with that in mind. Manufacturers do not design installs, we do.
@navitascp
@navitascp Жыл бұрын
Thanks for watching Mark. You keep doing what you’re doing 🙌🏽
@eddie_pegasus_electrical
@eddie_pegasus_electrical Жыл бұрын
💯 Good explanation on thermal effects with external equipment.
@navitascp
@navitascp Жыл бұрын
Thanks for watching, really glad you found it helpful 👍🏼😁
@BryanTheSpark
@BryanTheSpark Жыл бұрын
Great video, gives everyone something to think about. More company’s should be as open as you guys
@adoughertycontracting7243
@adoughertycontracting7243 Жыл бұрын
Top video mate, really good points. Look forward to seeing these tool bags!
@navitascp
@navitascp Жыл бұрын
Thank you! And thanks for watching
@scottsparky1
@scottsparky1 Жыл бұрын
In the past I used to do work on caravan sites. And all the feeder pillars for the vans had rcds in side them and they were basically an ip rated plastic db fixed to a stake in the ground.
@navitascp
@navitascp Жыл бұрын
Thanks for watching. Those RCDs will be subject to thermal derating as well. So this should of been taken into account at installation. Like I said in the video, the installer needs to be aware of the impact it will have on the particular brands device, and calculate the parameters accordingly 👍🏽
@scottsparky1
@scottsparky1 Жыл бұрын
@@navitascp this was in the early 2000 and I was just an apprentice. Back then rcds were just starting to be a thing.
@abdulseaforth6930
@abdulseaforth6930 Жыл бұрын
Thank you, my man!
@navitascp
@navitascp Жыл бұрын
Thanks for watching 👍🏽
@sergiofernandez3725
@sergiofernandez3725 Жыл бұрын
Interesting discussion topic Will. If the CU is outside what about condesation and corrosion? Warm air inside the CU meets colder air outside the CU will get condesation and also the humidity of the air inside and out. I assume a automatic pressure release valve could be used to help the heat escape without allowing the water to enter however people think drilling a drain hole will do the same thing. Thus the IP rate is voided. Insulated CUs could be an answer to the tempreture differntial as could a warming element in the CU. Likelihood of mechanical damage is another thing to consider. (IK rating) I look forward to see how this plays out.
@navitascp
@navitascp Жыл бұрын
Completely agree and the more this topic expands the more questions will come from it, especially over time as affects of the situation begin to mature. Like I said in the video, it’s not something I would like to see a Verso unit used for. However, as I can only speak for our brand, that’s where I’ll leave it ;)
@johnmcfadden7418
@johnmcfadden7418 Жыл бұрын
Nice video very interesting thx
@navitascp
@navitascp Жыл бұрын
Thanks for the feedback! Glad you found it helpful 🙌🏽
@matbaglow4618
@matbaglow4618 Жыл бұрын
Very interesting and informative! Cheers bud
@navitascp
@navitascp Жыл бұрын
Thanks mate glad you found it helpful 🙏🏽
@stephenmoore2840
@stephenmoore2840 7 ай бұрын
D.B.s in feeder pillars must endure a lot of temperature fluctuations. And MCBs and RCBOs etc inside BMS panels can get really hot because of all the relays and starters etc. I have opened control panels before and been met with a blast of hot air kind of like when you open an oven. That really can't be good, even if the cable is tri rated
@navitascp
@navitascp 6 ай бұрын
No you’re right, and not enough time is spent educating the industry on the impact of thermals on all of our circuits, cables, contacts etc
@JKElectricalltd
@JKElectricalltd Жыл бұрын
👏👌
@navitascp
@navitascp Жыл бұрын
Thanks for watching
@JKElectricalltd
@JKElectricalltd Жыл бұрын
@@navitascp always 👍
@abasimustafa
@abasimustafa Жыл бұрын
Never understood why people would literally sit and watch a person talk on screen.
@navitascp
@navitascp Жыл бұрын
By all means watch something else 👍🏽 but thanks
@AGRElectrics
@AGRElectrics Жыл бұрын
So fit an outside board and fit 16mm SWA for a EV charger 🤣
@navitascp
@navitascp Жыл бұрын
Thanks for watching. Makes no difference if you use 2.5 T&E if the water ingress gets in the glad, your stuffed lol like i said though, I’m far less worried about the board and more worried about the thermal factors 👌🏽
BIDIRECTIONAL MYTH BUSTING!
9:35
NAVITAS
Рет қаралды 4,6 М.
SHOULD YOU FIT AN IP65 CONSUMER UNIT
13:26
NAVITAS
Рет қаралды 639
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 16 МЛН
Quilt Challenge, No Skills, Just Luck#Funnyfamily #Partygames #Funny
00:32
Family Games Media
Рет қаралды 55 МЛН
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 127 МЛН
Арыстанның айқасы, Тәуіржанның шайқасы!
25:51
QosLike / ҚосЛайк / Косылайық
Рет қаралды 687 М.
THE IP RATINGS YOU NEED TO STAY COMPLIANT
8:40
NAVITAS
Рет қаралды 626
Nightmare Consumer Unit Change... Electrician Life
18:26
Artisan Electrics
Рет қаралды 90 М.
CAN YOU USE DIFFERENT BRANDS IN THE SAME CONSUMER UNIT?
9:16
5 SIMPLE STEPS TO STOP THERMAL DERATING
12:31
NAVITAS
Рет қаралды 457
OUTSIDE CONSUMER UNITS...A CONTROVERSIAL TOPIC!!  HERE'S MY VIEW.
11:52
SOTA Electrical
Рет қаралды 12 М.
Should you install a full AFDD or RCBO CONSUMER UNIT?
10:24
DEATH TRAP CONSUMER UNIT - Electrician Life
25:24
Artisan Electrics
Рет қаралды 100 М.
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 16 МЛН