Not only show You will explain every point and every block of this program
@plc247automation62 жыл бұрын
Please go to the article to read the details
@Kazimroza4u4 ай бұрын
Hi i am having two v20 drives connected to cpu 1214. They are running in auto mode with analog input controlling frequency. Also the inverters are connected to cpu thru modbus. Currently i had a drive issue and replaced with new drive. Now the drive is running but the rpm, current data not coming in cpu. Kindly guide
@strat_egi10 ай бұрын
I wanted to use your guide for setting up the device. but unfortunately it does not have such parameters. how to find them? Unfortunately I can’t configure it through macros. sinamics v20 fsc
@uditsaxena384420 күн бұрын
Please explain how you got this number1151 and 3199 in your network 4 branch
@syedyasirhussain9302 Жыл бұрын
Do you have video on S7 200 & Micromaster 420 USS Protocol communication?
@ΑγγελοςΔημογλου-π7ι11 ай бұрын
i followed exactly your video and i still have no connection from my rs485 leds are off....i used both channel 10 and 11 to try modbus rtu connection but no connection do i miss something thats not on the video?
@murilohenriquepereira9771 Жыл бұрын
Goodnight! to make modbus communication with several inverters in cascade as you would indicate?
@devendrachowdary23337 ай бұрын
I have a doubt how can we assume and add those numbers to control word to control on and off or rev or fwd .i didn't see those numbers in manual Can you explain me sir
@global-tech3203 Жыл бұрын
Hello dear I got a fault 8180 on my master bloc or my id port is correct. Could you please helping me ??
@rubentjuuu6 ай бұрын
I'm using CB 1241 - 6ES7241-1CH30-1XB0 (rs485 module) but cannot get the communication to work using this tutorial. please help
@ahmedsami2270 Жыл бұрын
How to cancel the negative sign, as the speed value appears on the inverter screen as negative؟
@ajaydumka731 Жыл бұрын
Thank for such a informatic video. I want a solution , after setting all parameters in sinamic v20 the drive frequency limited to 22.74 hz only . As i already provide min and max frequency. Please help
@adolfoleonhernandezabadia53602 жыл бұрын
Mucho gusto, una consulta referente al modulo RTU, que referencia tiene Industry Mall, muchas gracias.
@caonhumr47516 ай бұрын
How to read faults via plc modbusRTU?
@logicmindautomation145811 ай бұрын
Hi, can you show your wiring on the plc from the drive?
@plc247automation611 ай бұрын
go to my website sir
@DomenicoMadeo Жыл бұрын
hello, if I change the frequency and it doesn't change on the v20 do I have a problem with communication? how can i check this?
@global-tech3203 Жыл бұрын
P1000 in you vfd must 5 for frequency control in modbus
@timschulle8238 Жыл бұрын
Can you make a video where you control the v20 with codesys? For Example with a Raspberry Pi. I am trying to control a v20 with modbus in codesys but i dont get the fault. I dont know what i did wrong. The videos with Siemens software exists often, but nowhere i found one with Codesys to control the v20. Thanks :)
@joeltshiela46053 ай бұрын
👍
@mohammedrezk8072 Жыл бұрын
why we use max for the scale o/p 16384 ?
@plc247automation6 Жыл бұрын
Sinamics V20 stipulates so
@mohammedrezk8072 Жыл бұрын
@@plc247automation6 sorry i don't understand what you mean
@josepintoferreira5454 Жыл бұрын
vc pode enviar o projeto para o tia portal
@OOOMuhammadSyahrulKhoiri4 ай бұрын
can you give me the program please? i cant download from your website sir
@ronnelelpa6878 Жыл бұрын
Make.a tutorial using factory Io..pick and place using analog signal
@josepintoferreira5454 Жыл бұрын
como baixar o projeto gostei muito
@MehediHasan-es5et2 жыл бұрын
+ Set Word 40100 = 1151 >>> Forward Run = 3199 >>> Reverse Run. How about 1151 & 3199, could you explain Please?
@henriqueteixeira1236 Жыл бұрын
Please go to the article to read the details
@global-tech3203 Жыл бұрын
1151 and 3199 there are hexadécimal code they was convert in décimal
@reduanchowdhury78103 ай бұрын
Bro I worked more than 12 hours on your project but not successful please help me
@Scheme_Match Жыл бұрын
#plc247Automation Sir I need to talk. How can i contact you