Single phase VFD for single phase motor

  Рет қаралды 22,711

ATO Automation

ATO Automation

11 ай бұрын

In many cases, there is no controller that directly controls the speed of a single-phase motor or mitigates the start-up shock. However, the ATO VFD is a bold attempt, specifically for single-phase motors. Order link: www.ato.com/single-phase-vfd

Пікірлер: 25
@otabektillavayev3309
@otabektillavayev3309 6 ай бұрын
Thanks of millions
@DKKHOAHOC
@DKKHOAHOC Ай бұрын
Could it run at 5hz frequency
@Aston677
@Aston677 6 ай бұрын
Is it started at full speed so the centrifugal switch stops and avoids overheating? Also can this work on a 1.1KW 2 Pole 240V 1.5HP Dual capacitor motor?
@ATOcom
@ATOcom Ай бұрын
Yes, it is recommended to run at a speed higher than 80% of the motor's rated speed to allow the centrifugal switch to open.
@anteleko2439
@anteleko2439 16 күн бұрын
Can VFD connect with two windings capacitor motor?, i have VFD only L1, L2, and two windings capacitor motor, can i connect it with capacitor on vfd output?
@leftright4450
@leftright4450 5 ай бұрын
Should i need to remove motor capacitor before installing VFD?
@ATOcom
@ATOcom 5 ай бұрын
You can test it without load. If it runs normally, you can try to drive the load. If the motor heats up normally, you don't need to remove the capacitor.
@theinel
@theinel 8 ай бұрын
Can we use any 3 phase VFD to control 1 phase motor?
@ATOcom
@ATOcom 8 ай бұрын
Ordinary VFD does not work, you can try turning off the phase loss protection.
@bryceg5709
@bryceg5709 8 ай бұрын
Could this be used to shift phase of equipment like a 3D printer where phase of equipment causes flickering of lights etc? To isolate and move equipment off 60 hz to say 59 hz
@ATOcom
@ATOcom 8 ай бұрын
Are you referring to a frequency converter? Check out this link: www.ato.com/1-phase-frequency-converter www.ato.com/3-phase-frequency-converter
@bryceg5709
@bryceg5709 8 ай бұрын
@@ATOcom while yes I am. no I am not. that is very expensive for my goal which is to vary the frequency of the power from 120 or 240V 60hz AC to maybe 59 hz or 61hz just some variable "off" the natural frequency of the mains power. where as those look like very high end ways to provide power that replicates that of overseas locations. by and large if you have something like electronics or a motor it doesnt so much care if it sees 50 or 60 hz. but since my power is 60hz my light bulbs are flickering at 60 hz and if I run say a 3D printer which is drawing current for the heaters and causing a harmonic then I get to live in a club which my printer is running. where as a VFD possibly I could use to modulate the frequency the 3D printer is seeing so maybe the lights wouldnt strobe. I do have an ATO drive for my drill press but I assumed that I shouldnt run that and tap a single leg of it to run q 3d printer which is why I am wondering how a single phase would do if it's not powering a motor but instead just an AC to DC power transformer at something near a 60 hz setting
@ATOcom
@ATOcom 8 ай бұрын
Currently, the only devices that can achieve the functions you mentioned are the ones I sent you the link to earlier...@@bryceg5709
@contomo5710
@contomo5710 7 ай бұрын
59 hz is a very bad choice, because there is gonna be 1hz flickering ^^, you know, one second they match, the other they dont.
@saifulbazlan4115
@saifulbazlan4115 7 ай бұрын
1 phase motor likes pump has a running capacitor..how to connect wire to the motor?
@automationwork5904
@automationwork5904 Ай бұрын
You can directly connect to the VFD without removing the capacitor. The operating speed is more than 80% higher than the rated speed of the motor.
@peterzylmans6099
@peterzylmans6099 3 ай бұрын
can this be used on a single phase 240 v milling machine or small lathes
@automationwork5904
@automationwork5904 Ай бұрын
Can use. However, it is not recommended to directly adjust the speed. When a single-phase motor is connected to a single-phase VFD, the low torque is not strong.
@ahmeda489
@ahmeda489 4 ай бұрын
Can you reverse it?
@ATOcom
@ATOcom Ай бұрын
You can only reverse the rotation of the motor through the wiring indicated on the motor nameplate.
@pratheeshtom4758
@pratheeshtom4758 27 күн бұрын
Price?? Its possible sensor control
@Clips870
@Clips870 4 ай бұрын
Price kitna hain
@ATOcom
@ATOcom 4 ай бұрын
For the latest price, visit here: www.ato.com/single-phase-vfd
@sudarshans2861
@sudarshans2861 7 ай бұрын
availably in india? whats the price ? what is the contact number
@ATOcom
@ATOcom 7 ай бұрын
This link,www.ato.com/single-phase-vfd
How to control multiple VFDs via Modbus (RS485)
4:54
ATO Automation
Рет қаралды 1,8 М.
What Types of Motors Can Be Used with VFDs?
6:58
eMotors Direct
Рет қаралды 63 М.
버블티로 체감되는 요즘 물가
00:16
진영민yeongmin
Рет қаралды 96 МЛН
WHO DO I LOVE MOST?
00:22
dednahype
Рет қаралды 79 МЛН
когда повзрослела // EVA mash
00:40
EVA mash
Рет қаралды 3,5 МЛН
ИРИНА КАЙРАТОВНА - АЙДАХАР (БЕКА) [MV]
02:51
ГОСТ ENTERTAINMENT
Рет қаралды 8 МЛН
Variable Frequency Drives Explained - VFD Basics IGBT inverter
15:18
The Engineering Mindset
Рет қаралды 3 МЛН
1 phase 220v to 3 phase 380v 7.5kw/11kw VFD/inverter transformer
4:24
SINGLE PAHSE MOTOR SPEED CONTROLLER - INVENTION CONTROL - 9790046788, 9952255254
1:20
INVENTION CONTROLS KARTHICK
Рет қаралды 93 М.
How to make a Variable Frequency Drive (VFD) | 3: Software
13:25
How to Connect a Single Phase Motor
7:42
Jean B
Рет қаралды 604 М.
Single-phase VFD drive single-phase motor parameter setting(KE300A)
4:20
Connecting a 120V VFD to single phase PSC motor in my bench grinder
15:20
Prairie Edge Service
Рет қаралды 12 М.
YOTAPHONE 2 - СПУСТЯ 10 ЛЕТ
15:13
ЗЕ МАККЕРС
Рет қаралды 151 М.
В России ускорили интернет в 1000 раз
0:18
Короче, новости
Рет қаралды 1,1 МЛН
ПОКУПКА ТЕЛЕФОНА С АВИТО?🤭
1:00
Корнеич
Рет қаралды 3,4 МЛН
iPhone 16 с инновационным аккумулятором
0:45
ÉЖИ АКСЁНОВ
Рет қаралды 1,2 МЛН