Single Phasing Fault in 3 - Phase Motor | Motor Single Phasing

  Рет қаралды 27,246

Electrical lectures

Electrical lectures

Күн бұрын

Single phasing fault in 3 - Phase motor is considered to be the very serious fault because in running condition when single phasing occur or when one phase break or disconnected, the motor tries to rotate the load in turn it draws excessive current which results in burning of windings.
I have also showed how much current will flow when single phasing occur.
#singlephasing #singlephasingmotor #electricmotor #electricallectures

Пікірлер: 40
@myasir8129
@myasir8129 2 жыл бұрын
very serious fault well explained
@bnee4313
@bnee4313 9 ай бұрын
does motor starter turn off if one phase is missing while in operation?
@muhammadwaqas427
@muhammadwaqas427 2 жыл бұрын
Grateful. How can we avoid single phasing
@ElectricityFrenzy
@ElectricityFrenzy 2 жыл бұрын
You can use phase loss protection relay.
@that1electrician
@that1electrician 9 ай бұрын
Size your overloads properly.
@bernardob.bacanijr9365
@bernardob.bacanijr9365 2 жыл бұрын
What do you use in 3phase motor to avoid damaging? thank you
@electricallectures
@electricallectures 2 жыл бұрын
Overload relay whether it is thermal or electronic but I would prefer electronics for its accuracy. OL protects the motor in event of faults
@haxboi5492
@haxboi5492 Жыл бұрын
Use a breaker that pops all three phases instead of seperate ones
@that1electrician
@that1electrician 9 ай бұрын
​​​@@haxboi5492Wrong answer. Breakers are used as short-circuit protection. Single-phasing is NOT a short circuit, so chances are your motor is gonna burn up long before your breaker ever trips. Overloads are designed to catch things like single phasing. The bimetal element will heat up and trip a lever that'll drop out the auxiliary OL contact that's wired in series with your contactor coil. Size your overloads (and motor branch circuit wiring) correctly... 125% of FLA.
@Xtreme49
@Xtreme49 Жыл бұрын
If one of the phase gets loss but the fuse to that phase is still close will backfeeding happen back through that phase. In a 3Ph 4 Wire system
@electricallectures
@electricallectures Жыл бұрын
Its not that for no reason phase is lost. Without any thing open circuit from load to sorce, the phase cant be lost. In that case no current will flow in it
@jbthegreatvlogs523
@jbthegreatvlogs523 2 жыл бұрын
Thanks i learn more about elec.
@conybrown991
@conybrown991 Жыл бұрын
Experienced this first hand 10 years ago, i was blamed of purchasing an incompitable motor by an AM who was responsible for electrical installations from MCC to motor. I knew very well the motor i chose was compitable to the system as it was a duty standby design and duty one had been working normally without a single fault for 3 months. When the standby pump manual start button was pressed, the motor started to rotate and within a mintue 10K USD was lost. PM asked the AM to check the system comprehensively and the AM replied everything was checked, nothing unusual was found, and it was my mistake leading to the loss. I was then asked to purchase another motor to correct my mistake, and within a mintue after the pump was started another 10K USD was lost. The PM then asked the motor supplier to check what happended and figured out one phase wire was not connected at all. From the very beginning to the end, the PM didn't blame me and I didn't say a single word on this, but the AM never aplogized this.
@electricallectures
@electricallectures Жыл бұрын
Unfortunate but that happens in the field. Thanks for sharing your experience
@that1electrician
@that1electrician 9 ай бұрын
So like, you don't ohm out all your coils and do a megger test before installing a new motor? That's like rule #1 my guy. Make sure you're not about to waste your time rigging in and connecting an already-bad motor...
@bernardob.bacanijr9365
@bernardob.bacanijr9365 2 жыл бұрын
Can you tell me what are the problems of single phasing protection for 3 phase system can you ask for 3 to 5 problems? sir thank you
@electricallectures
@electricallectures 2 жыл бұрын
I dont cleay understand what u want to ask
@shivamrathi987
@shivamrathi987 Жыл бұрын
overheating, insulation damage, vibration
@jbthegreatvlogs523
@jbthegreatvlogs523 2 жыл бұрын
Jb the great vlogs sending you a full support
@electricallectures
@electricallectures 2 жыл бұрын
Thanks alot
@mohdhazhari3778
@mohdhazhari3778 2 жыл бұрын
I had problem..got voltage on all phases but no amp on Red phase..what causes the problem?
@electricallectures
@electricallectures 2 жыл бұрын
Ur connection to the motor is open. From contactor
@mohdhazhari3778
@mohdhazhari3778 2 жыл бұрын
@@electricallectures u mean the winding?already check the connection,all in good order..been doing continuity test..got reading on w1-v2..its not normal rigth?
@mohdhazhari3778
@mohdhazhari3778 2 жыл бұрын
@@electricallectures im using auto trans starter..when switch on,run and star contactor energised..got amp reading on Red phase,but when main contactor energised,the amp on R are 0 amp
@electricallectures
@electricallectures 2 жыл бұрын
If star delta starter is used tgen delra contactor j Has one phase open
@bhupendraaditya6960
@bhupendraaditya6960 Жыл бұрын
Thank u so much sir.
@electricallectures
@electricallectures Жыл бұрын
Thanks. Stay tuned and dont forget to subscribe plz
@BaconPersuasion
@BaconPersuasion 2 ай бұрын
This video saved many thousands of dollars in component loss in a multi million dollar aircraft..... I hope.
@electricallectures
@electricallectures 2 ай бұрын
Thanks. Stay tuned and don't forget to subscribe plz
@binonna7980
@binonna7980 10 ай бұрын
how 173 % comes
@SyedAlthaf-hg2kn
@SyedAlthaf-hg2kn 6 ай бұрын
One phase high amppere problem solution
@myasir1355
@myasir1355 2 жыл бұрын
@el-dorado4645
@el-dorado4645 2 жыл бұрын
how to carry test
@electricallectures
@electricallectures 2 жыл бұрын
What type of test
@el-dorado4645
@el-dorado4645 2 жыл бұрын
like Earth fault ,short circuit test how check that which phase is fault
@electricallectures
@electricallectures 2 жыл бұрын
This can be done manually through multimeter after disconnecting the motor
@el-dorado4645
@el-dorado4645 2 жыл бұрын
how we check in motor terminal box
@electricallectures
@electricallectures 2 жыл бұрын
Best way to check it first from the contactor then come to motor terminal
@anonymousperson2578
@anonymousperson2578 Жыл бұрын
Jogdish? Is that you?
Insulation Resistance Test | Understand Megger Test Results
10:26
Electrical lectures
Рет қаралды 12 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,3 МЛН
А что бы ты сделал? @LimbLossBoss
00:17
История одного вокалиста
Рет қаралды 8 МЛН
Synyptas 4 | Арамызда бір сатқын бар ! | 4 Bolim
17:24
Это было очень близко...
00:10
Аришнев
Рет қаралды 1,6 МЛН
Overcurrent, Overload, Short Circuit, and Ground Fault
6:54
Dave Gordon
Рет қаралды 893 М.
How does a fan work ? | Single phase induction motor
13:13
Prof MAD
Рет қаралды 32 М.
My motor is single-phasing!
10:42
Serge Levesque
Рет қаралды 10 М.
3 phase motor test
10:58
chriskitcher
Рет қаралды 1,6 МЛН
What is the Difference Between Single Phase and Three Phase???
23:11
Electrician U
Рет қаралды 600 М.
3 PHASE MOTOR TESTING - how too PROPERLY
39:04
Actual Electrical Content with Jamie blatant
Рет қаралды 38 М.
Typical failures in three phase electric motor windings
5:18
Fletcher Moorland
Рет қаралды 18 М.
How Electric Motors Work - 3 phase AC induction motors  ac motor
15:34
The Engineering Mindset
Рет қаралды 6 МЛН
Troubleshooting 3 phase motors
11:45
Big Mike H
Рет қаралды 9 М.
# Single Phasing Fault in 3-Phase Motor # Causes,  Effects & Protection #
16:05
TS - Electrical & General
Рет қаралды 648
А что бы ты сделал? @LimbLossBoss
00:17
История одного вокалиста
Рет қаралды 8 МЛН