Size of Column for Ground Floor - G+1 and G+2 Domestics Building | Standard Size of Column for House

  Рет қаралды 129,983

Civil Engineers

Civil Engineers

3 жыл бұрын

1) Construction cost of 1000 square feet House 2019? Cost of House Construction per square foot 2019
• Construction cost of 1...
2) Grade Of Concrete and water Cement Ratio
• Grade Of Concrete and ...
3) How to calculate Cement, Sand, and Aggregate for M20 concrete
• How to calculate Cemen...
4) Depth of Footing/Foundation and Reinforcement details in Foundation
• Depth of Footing/Found...
5) Maximum distance between two RCC columns?
• Maximum distance betwe...
6) Big Mistakes in RCC Slab - Lapping Mistakes
• Big Mistakes in RCC Sl...
play Lists :
Construction Videos :
• How to Chose Good Qual...
Construction Site Visit :
• New Exterior Design fo...
House Planning Play List :
• How to Study Column wi...
#CivilEngineers #CivilEngineering

Пікірлер: 110
@yussufabdullahi4782
@yussufabdullahi4782 2 жыл бұрын
Watching your videos from Somalia 🇸🇴 I will never hesitate viewing the videos u post
@godwinmwakalinga8590
@godwinmwakalinga8590 2 жыл бұрын
Sir. You're doing very good job. Your videos are very useful for many people around the world. I'm from Africa, Tanzania East Africa. Real impressed with your teachings. God bless you Sir
@luimackjohnson302
@luimackjohnson302 2 жыл бұрын
Superb! Thank you for sharing this video! Precise to the point! Greetings from Papua New Guinea.
@josejasongalo2199
@josejasongalo2199 2 жыл бұрын
New subscribershoutout from Philippines....i like you the way u teach engineer...very informative...god bless
@TheMaru71
@TheMaru71 2 жыл бұрын
Very clear and understanding. Thanks
@omyadav13
@omyadav13 2 жыл бұрын
Very good explanation. Thank you so much.
@Fundamental_Gospel
@Fundamental_Gospel 2 жыл бұрын
I never miss your video..simple and very clear to understand! I have a request sir, please always add video to support your explanation! It will be easier to understand!🙏
@siliconcity4739
@siliconcity4739 Жыл бұрын
P
@akonitv9781
@akonitv9781 2 жыл бұрын
very informative Sir from Philippines ❤️❤️❤️
@umeshkrishnan9625
@umeshkrishnan9625 Жыл бұрын
Very good teaching.
@sulemanasrat9651
@sulemanasrat9651 Жыл бұрын
You are real engineer,
@bowobudiarso7656
@bowobudiarso7656 2 жыл бұрын
Thank's , sir, your content very usefull
@phyohtetkoko929
@phyohtetkoko929 2 жыл бұрын
Sir Thanks For Teaching 👍🏻✌🏻
@kyawnaing8916
@kyawnaing8916 2 жыл бұрын
Thanks for knowledges, sir.
@c.rajendranchinnasamy8929
@c.rajendranchinnasamy8929 5 ай бұрын
Very useful and highly informative video .... Thanks ...
@gopalsripati1110
@gopalsripati1110 Жыл бұрын
Excellent very well explained
@franciscogago8156
@franciscogago8156 2 жыл бұрын
Thanks ait for the video and the messages.
@mahamidabdirisaak7062
@mahamidabdirisaak7062 2 жыл бұрын
Hi teacher I am happy for the luncher
@ebirootookubivunulanokuyam4414
@ebirootookubivunulanokuyam4414 2 жыл бұрын
Thanks for the information brother
@dragb6281
@dragb6281 2 жыл бұрын
Structural design should not be prescriptive. For column design, you didn’t consider : 1. Braced or unbraced column; 2. Column span and column moment generated; 3. Column height and hence its slenderness; 4. Impose live load . Factory is much heavier than residential ;
@LanguiYang
@LanguiYang Жыл бұрын
Thank you
@amprayilchackoabraham4800
@amprayilchackoabraham4800 2 жыл бұрын
Thank you very much
@atifchoudhary3339
@atifchoudhary3339 11 ай бұрын
Good knowledge thank you
@maxwellosazuwa6153
@maxwellosazuwa6153 2 жыл бұрын
Thanks sir, please can you explain the depth of the pillar footings for a G+2 storey building. All together.
@waluohopaulo2116
@waluohopaulo2116 2 жыл бұрын
Well understood 👍🏿
@karthickrajas664
@karthickrajas664 2 жыл бұрын
Good job from TN
@zebra5star925
@zebra5star925 4 ай бұрын
Very helpful 👍👍👍
@megadesignarch4023
@megadesignarch4023 2 жыл бұрын
Very informative
@advocateishengoma1088
@advocateishengoma1088 Жыл бұрын
Thanks you a good kind of brother
@mianwaliptitiger960
@mianwaliptitiger960 Жыл бұрын
V v nice always b Happy Thanksgiving and very informative video
@alfrasyadibrahim9730
@alfrasyadibrahim9730 2 жыл бұрын
Great thank you!
@ojetolasunday5258
@ojetolasunday5258 Жыл бұрын
Thank you sir
@gripofnurses
@gripofnurses Жыл бұрын
Good work 👍
@jundurahman1
@jundurahman1 Жыл бұрын
Very informative video
@bluesky2143
@bluesky2143 5 ай бұрын
Very good ❤
@venkatasubbaraopathipati5815
@venkatasubbaraopathipati5815 11 ай бұрын
Really useful 👌👌👌🙏
@Mani6560Xv
@Mani6560Xv 2 жыл бұрын
SO INTERESTING
@knowledge-is-infinite
@knowledge-is-infinite 2 жыл бұрын
Can we use 16mm(4no.) and 12mm(4no.) for G+3 floors ?
@Sadiq1282
@Sadiq1282 2 жыл бұрын
Always very informative and correct information..Sir for G+2 is 10 ft by 14 ft column OK..Plz reply.
@RakeshSharma-kq2ux
@RakeshSharma-kq2ux 2 жыл бұрын
Hi, Can we provide 6mtr height of each bars for 1 floor from footing to 1st Floor? Means i want to put 6 nos of 6mtr height bar of 12mm dia in 9x12 inch column without any lapping.
@douglasmiller4112
@douglasmiller4112 2 жыл бұрын
I need similar lecture for residential wood construction.
@vincentpaul4004
@vincentpaul4004 2 жыл бұрын
Very good
@rock4everification
@rock4everification Жыл бұрын
What happens if my constructors did for G+2, 200mm spacing between stirrups in my columns? They didnt do 100mm at endings of the colums. Entire column is with 200mm stirrups. They used 250mmx450mm column, 10 bars 16mm corners, and inner bars 14mm. Thanks!
@tuancassim2168
@tuancassim2168 Жыл бұрын
My house I already have 9" column with 16mm 4 steel bar, cld I have only one stored with roof top slab is strong enough with this column 9" column? Pls explain Tnx
@ronaldjamesyagono7777
@ronaldjamesyagono7777 2 жыл бұрын
Engr. What if G+ 1 story but the roof is steeldeck/metal deck (roofdeck)can i still use the 9" x 12" of volumn?
@samiullahk7223
@samiullahk7223 2 жыл бұрын
I got a design for G+2 with no tmt in 12" section all 3+3, 4 16mm and 2 12 mm in the 9" side, will it support torstion load? I studied som and am dumb found at the design
@hussainshareef5603
@hussainshareef5603 2 жыл бұрын
How to join old column of ground floor to first floor column. Is it safe to do that way? I want build first floor. Room size is 20feet 20feet. Already have footing in ground floor.
@yawyaw8556
@yawyaw8556 2 жыл бұрын
Can I use 4 rod with 14 dis for columns to build one stored throughout
@francisjadaraaedu1955
@francisjadaraaedu1955 2 жыл бұрын
Hei, how are you doing. What could be the estimated size of column for G+3
@sattarj.al-hashemi5049
@sattarj.al-hashemi5049 2 ай бұрын
Great vidi by
@santramkosaria5947
@santramkosaria5947 Жыл бұрын
Sir , can we keep 9"*15" collumn size for G +2 residencial building?
@khawajakhursheed1495
@khawajakhursheed1495 Жыл бұрын
Good
@ashokaashoka1558
@ashokaashoka1558 2 жыл бұрын
Super sir
@jangit9536
@jangit9536 2 жыл бұрын
Can I use 20mm tmt for G+2 house.
@hemuhemu8538
@hemuhemu8538 2 жыл бұрын
Tq sar
@godson5711
@godson5711 2 жыл бұрын
What will happen if 16mm is replaced with 12mm in the G+1 floor . Meaning 6-16mm is used throughout. Is it better/advisible??
@user-bn3wx1xd8u
@user-bn3wx1xd8u 6 ай бұрын
Can we use marble pieces for concrete cover or anything else?
@akonitv9781
@akonitv9781 2 жыл бұрын
In my future house has G+1 with Roof Deck is it advisable 9"x12" (6no. 16mm) size of house 7x9.2Meters? Please reply thanks
@shaneangeles8839
@shaneangeles8839 2 жыл бұрын
What is the size of the column for a 3- storey building with 2 stories under the backfill???
@samuelb6877
@samuelb6877 Жыл бұрын
Is it compolsory to use rectangle colum in G+1. Can we use square colum
@edwinmoree833
@edwinmoree833 2 жыл бұрын
Sir would you please do a video on basement
@jauspreetkaur2489
@jauspreetkaur2489 Жыл бұрын
Your explanation is very good , Sir g+1 ka detailed estimate ka video banayi plzz .....
@yousafkhan7622
@yousafkhan7622 2 жыл бұрын
sir,waiting for vedio G+1 G+2 beam with details pls.thank u
@MayungoNamushi
@MayungoNamushi Жыл бұрын
I love
@Rahul-nl3dy
@Rahul-nl3dy 2 жыл бұрын
Sir can we use 6 rods 9×15 size column
@emmatony02
@emmatony02 2 жыл бұрын
If one wants to build a G + 2 building, Can one then start the foundation with the 12x12 inches column size of 8 steel rods 16mm for the ground then use column 12x9 inches with 6 steel rods 4x16mm and 2 x 12mm for the first floor and then finally use 9x9 inches of 4 rods of 12 mm? Just reversing through.
@knowledge-is-infinite
@knowledge-is-infinite 2 жыл бұрын
Is it possible ?
@sharpblade4you
@sharpblade4you Жыл бұрын
Yes
@sahidbangura8294
@sahidbangura8294 2 жыл бұрын
Which country you leave at? I like the way you teach just like my teacher b4
@premjitchakpram4201
@premjitchakpram4201 2 жыл бұрын
For G+2 how about the steel rod 16mm(4no.) and 12mm(4no.) for column. I have used in my house is it safe?
@rzgarasadd2395
@rzgarasadd2395 2 жыл бұрын
very safe and not economical not need use 8 no bars
@santharamb3584
@santharamb3584 2 жыл бұрын
Your explanation super sir
@knowledge-is-infinite
@knowledge-is-infinite 2 жыл бұрын
What about for G+3 ?
@yaqoobansari738
@yaqoobansari738 2 жыл бұрын
What about beam and footing ????
@ibomchakhundrakpam6220
@ibomchakhundrakpam6220 2 жыл бұрын
Sir can we mix the rod(12mm and 16mm)when making a coulum?
@RockFoundation
@RockFoundation 2 жыл бұрын
Yes u can sir
@reviewmaster7359
@reviewmaster7359 2 жыл бұрын
G+1......6 pis 12 mm in tata tiskon 550 sd mana mara ghar ma use kiya & colum size 10/10 kya koi problem hoga
@sayemchowdury5761
@sayemchowdury5761 2 жыл бұрын
how much the footing of G+1 & G+2
@mabraty8837
@mabraty8837 Жыл бұрын
For ground floor 9*9, 9 feet or 9 dm?
@washunabate9739
@washunabate9739 2 жыл бұрын
What about the depth of founddtion
@defenderslamare7266
@defenderslamare7266 2 жыл бұрын
👌👌👌
@fredericklaxa4507
@fredericklaxa4507 8 ай бұрын
Sir what if the bars I use is 6 PCs 16 mm and 2 PCs 12 mm for g+2 storey 10 mm lateral tie spacing of 150 mm is that ok sir
@ayoubarshad697
@ayoubarshad697 2 жыл бұрын
Sir Kia g+1 story main 4 bar 12 mm and 2 bars 19.1 mm can be used?????
@priyanksinghsengar6454
@priyanksinghsengar6454 Жыл бұрын
kya use kiya?
@Nagar_Boy
@Nagar_Boy 4 ай бұрын
House planning g+1 for column size 9x9inches 4 steel bar 16mm strong column, house size 20x20fi.
@bhumirajrai6466
@bhumirajrai6466 2 жыл бұрын
🙏🙏
@talithaiitalithaii7261
@talithaiitalithaii7261 2 жыл бұрын
👍👍👍
@bungoningthoujam1680
@bungoningthoujam1680 2 жыл бұрын
For g+2 can we use only 6 nos, 16mm steel bar
@mazalam6031
@mazalam6031 Жыл бұрын
In another video u prescribes entirely different steel reinforcements for g+1
@mahendarnenavath7539
@mahendarnenavath7539 Жыл бұрын
Sr footing depth and width sr ?
@kannansenthilkumar5229
@kannansenthilkumar5229 2 жыл бұрын
Sir no mention that footing size and rebar.
@vincentpaul4004
@vincentpaul4004 2 жыл бұрын
Putting sizes
@vincentpaul4004
@vincentpaul4004 2 жыл бұрын
G+2 and G+3 putting sizes
@longjamvlogs4880
@longjamvlogs4880 Жыл бұрын
Mistake for columns of g+2 is (16mm =8).it should be 16mm=4, 12mm=4.
@kamalabd2705
@kamalabd2705 2 жыл бұрын
sorry but the size of column can not be decide like this.. u shoul know what loads this column is carring .. then check moments.. two side.. then find the required steel the .. then ckeck the mode of failure of column.. and finaly find the dimension of column..
@CivilEngineerss
@CivilEngineerss 2 жыл бұрын
As u told you this is not for student
@kamalabd2705
@kamalabd2705 2 жыл бұрын
@@CivilEngineerss i am not student .. but i wrote it from designing background .. as we do in etabs or manual check for design .. thank u for ur time
@ManojKumar-ug7od
@ManojKumar-ug7od 2 жыл бұрын
Sir 10"×10" column size can we built G+1 We use 16mm of 4 bar
@masternobody1896
@masternobody1896 2 жыл бұрын
very epic video
@Fundamental_Gospel
@Fundamental_Gospel 2 жыл бұрын
Yes, you can build it..
@satheeshkumarduraisamy5938
@satheeshkumarduraisamy5938 2 жыл бұрын
G+2 , Column Size is 12*12 with 8 no of 16mm Rod with 8mm strips for a standard distance of 12 feet column. But What is the column & beam size , if the column distance is 18 to 19 feet? Please post a video for (40* 60) 2400SQFT G+2 story building, Ground floor ONE (1050 SQFT 2 BEDROOM) House with 1000SQFT for car parking and 1st floor with TWO (1050 SQFT 2 BEDROOM House) assume atleast for 2 columns the distance is 16 to 17 feet Detail the G+2 story, footer, Plinth beam, Column, beam and Slap size
@samiullahk7223
@samiullahk7223 2 жыл бұрын
No column should exceed 15 feet from each other, else cracks
@uzairsdiary3455
@uzairsdiary3455 2 жыл бұрын
Supreb I would like to do internship with you as a civil engineer
@lingarajswain3086
@lingarajswain3086 3 ай бұрын
G+2 kelia pillar size 12*12 inch or 9*15 inches hona chahia
@mygarden2694
@mygarden2694 Жыл бұрын
My column size 10"x10" I making G+1floor steel 6pcs 4pcs16mm 3pcs 12mm column distance 12'x13'..center column 10"x10" 6pcs 16mm steel.👉👉👉👉
@mygarden2694
@mygarden2694 Жыл бұрын
Pls I m waiting your answer 🥺🥺🥺🥺🥺
@JHANDEER
@JHANDEER 2 жыл бұрын
Assalam Alikum Sir, I from Saudi Arabia i m going to Build my home in Pakistan in my City we are using Bricks size 9" 4.5" and 6" by 9" mostly 6" by 9" so my questing is is can be comfortable bricks to use 6" by 9" with column size 6" by 18" the plot size is 2700 S. ft please advise.
@danichwarymbai7222
@danichwarymbai7222 2 жыл бұрын
For G+1 can we use 12mm of 8 bars
@sharpblade4you
@sharpblade4you Жыл бұрын
Yes
Size of Beam , Size of Column and Spacing between Two Column
13:01
Civil Engineers
Рет қаралды 363 М.
Tom & Jerry !! 😂😂
00:59
Tibo InShape
Рет қаралды 66 МЛН
Incredible magic 🤯✨
00:53
America's Got Talent
Рет қаралды 41 МЛН
Column Span v/s Column Size | #shorts #saconstructionwithrahul
0:59
SA construction with rahul
Рет қаралды 101 М.
Column Distance v/s Column Size | Based on Thumb rule
5:13
Irfan Site
Рет қаралды 21 М.
5 Important Rules of Beam Design Details | RCC Beam | Green House Construction
8:45
NHÀ XANH VIỆT NAM
Рет қаралды 2,1 МЛН
Maximum distance between two columns | Column size and steel details for G, G+1, G+2, G+3 | column
5:21