SM35 Parallel Operation of Alternators under Loaded condition

  Рет қаралды 18,679

Lectures in Electrical Engineering

Lectures in Electrical Engineering

Күн бұрын

Пікірлер: 30
@ठाड़ाचेला
@ठाड़ाचेला 3 жыл бұрын
वाह मजा आ गया सर जी इसमे तो,ये सच मे मैने पहले नही पढ़ा, धन्यवाद
@johnhonai4601
@johnhonai4601 Жыл бұрын
Thank you, Sir. I used to learn byheart "Excitation Increase, KVAR increase". But this diagrammatic representation helps very much.
@rupaliukey2909
@rupaliukey2909 5 жыл бұрын
Salute sir ,the way you are teaching is excellent ,I have done coaching in topmost academy but still i get something new from your lectures , no one explained this in detail ,tysm🙏
@dmo4657
@dmo4657 4 жыл бұрын
Sir, at 17:10 you have taken the angle ⌀2 from the kVAR axis. If power factor is decreasing then the angle ⌀ is supposed to be increasing.
@surendrakverma555
@surendrakverma555 2 жыл бұрын
Excellent lecture Sir. Thanks 🙏🙏🙏🙏🙏🙏🙏🙏🙏
@satyavara6276
@satyavara6276 4 жыл бұрын
Excellent explanation sir
@sheshusmart3300
@sheshusmart3300 3 жыл бұрын
Tq you saved my sem
@visheshsingh1238
@visheshsingh1238 4 жыл бұрын
Nice explanation sir
@gustavomarcelo7250
@gustavomarcelo7250 3 ай бұрын
How do we carry out the same analysis for 3 generators?
@prasannakumar2638
@prasannakumar2638 4 жыл бұрын
8:02 Since KVAR 1 and KVAR 1' are in negative y-axis, KVAR1 should be greater than KVAR1' right?
@dr.tirupathirajukanumuri4451
@dr.tirupathirajukanumuri4451 4 жыл бұрын
No
@pudurusuresh8644
@pudurusuresh8644 2 жыл бұрын
Sir at 22.23 why the two machines characteristics are falling down
@arindamchowdhury4734
@arindamchowdhury4734 4 жыл бұрын
Sir.. when load is connected .. if I increase excitation of one alternator.. then it will be accelerated.. because inorder to maintain same speed if excitation is increased then power angle(delta) should be reduced.. so ..will the whole combination will be distabalized??
@petchu2002
@petchu2002 4 жыл бұрын
Dear sir I have one more confusion that whenever we draw voltage vector for two alternator in opposite direction ,it means angle between them is 180? supposed to be both are peak at same instant ans zero at same instant means zero phase angle.
@MANOJKUMAR-mb2uw
@MANOJKUMAR-mb2uw 4 жыл бұрын
One shot clear🙏🙏🙏🙏
@muhammedanfas7873
@muhammedanfas7873 3 жыл бұрын
thank you sir ,thank you very much
@maheshwarreddy3656
@maheshwarreddy3656 5 жыл бұрын
Sir when alternator connected to bus bar if we increase prime mover input why speed is not changing?
@3dgiftz
@3dgiftz 2 жыл бұрын
Good
@shaileshbirajdar1963
@shaileshbirajdar1963 4 жыл бұрын
👏👏👏👏
@jassalg7169
@jassalg7169 2 жыл бұрын
Sir we can maintain stable power factor during parallel operation of alternator Sir actually during parallel operation when first alternator execution is increase then power factor of first alternator is leading and secondary alternator power factor automatically leading. Then second machine is tripping frequently due to reactivate power Sir how to solved this fault ? Pls reply 🙏
@petchu2002
@petchu2002 4 жыл бұрын
Dear sir Please clarify that at first vector diagram IxR and IxX why they are being drawn at this direction.IR might be in phase with V. Please explain the reason why they are drawn at that angle. Thanks
@petchu2002
@petchu2002 4 жыл бұрын
Dear Sir thank you very much for clarification and response. And I have one more confusion that whenever we draw voltage vector for two alternator in opposite direction ,it means angle between them is 180? supposed to be both are peak at same instant ans zero at same instant means zero phase angle.
@sasidher8922
@sasidher8922 4 жыл бұрын
Sir,what happens if prime mover has rising characteristics ,can't they share load equally in this case?
@sasidher8922
@sasidher8922 4 жыл бұрын
Sir, can you tell reason for it?
@er.imransiddiqui
@er.imransiddiqui 4 жыл бұрын
Sir, how can we say that the magnitude of generated voltage does not change with frequency although the emf equation(E=2.22 f × phi × Z) has the frequency term and what is justification for the change of phase of emf with frequency?
@er.imransiddiqui
@er.imransiddiqui 4 жыл бұрын
@@lecturesinelectricaleng I watched the video. What I am still thinking is that when the speed of the prime mover changes the frequency as well as the induced voltage must change. Because E= 4.44 f × phi × T.
@er.imransiddiqui
@er.imransiddiqui 4 жыл бұрын
@@lecturesinelectricaleng Ok sir. But then here in the second case you have assumed that the magnitude of E1 and E1' are same, only phase is changing. I want the reason for both - (1)why magnitudes have been considered same here and (2) what is the proof that phase changes with speed/frequency?
@er.imransiddiqui
@er.imransiddiqui 4 жыл бұрын
@@lecturesinelectricaleng Ok Thank you Sir.
@pbsaikumar3553
@pbsaikumar3553 4 жыл бұрын
Sir,please reduce the speed while explaining the any concept
@dmo4657
@dmo4657 4 жыл бұрын
Watch at 0.75 speed. The speed is fine.
SM36 V and Inverted V Curves of alternator
18:56
Lectures in Electrical Engineering
Рет қаралды 12 М.
SM34 Parallel Operation of Alternators under No Load
13:40
Lectures in Electrical Engineering
Рет қаралды 20 М.
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 18 МЛН
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
IL'HAN - Qalqam | Official Music Video
03:17
Ilhan Ihsanov
Рет қаралды 700 М.
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 54 МЛН
SM33 Synchronization Methods
12:51
Lectures in Electrical Engineering
Рет қаралды 27 М.
Parallel Operation of Alternators
19:21
Smile and Learn Abhiraj
Рет қаралды 94 М.
SM05 EMF Equation of Alternator
15:49
Lectures in Electrical Engineering
Рет қаралды 21 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 2,1 МЛН
Armature Reaction of Alternators [Year - 3]
8:04
Mobile Tutor
Рет қаралды 113 М.
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 18 МЛН