A short video demonstrating how to set the thermal regulation - please be careful when messing about with the ATR!!
Read First.
Turn the light on with 3 clicks (Battery check - ignore this stage)
Now double click 3 times (Temperature check - ignore this stage)
Now click 4 times. This puts the light in temperature calibration mode. Where we need to be There are two parts:
PART 1 - The light will blink once (part one) and then start to flicker. While the light is flickering, click in the room temperature. For example, if room temperature is 20C, click 20 times and wait for the light to stop flickering.
PART 2 - Now the light is going to blink twice (part 2) and again start to flicker, (this is for setting the thermal limit for the light to start stepping down) While it's flickering, click 30 times less than the step down temperature you want. For example to set the limit at 50C, click 20 times. If you want to set the limit at 55C, click 25 times. 60C would be 30 clicks. The default is 45C which is 15 clicks.
Once you're finished just wait a few seconds for the light to stop flickering. At this point the light will start to blink out its temperature (you're still in temp check) you can just click once and turn the light off.
Ready?
Make you sure you have the room temperature and set down temperature ‘number of clicks’ in your mind.
Then,
Turn on with 3 clicks
Double click 3 times
Click 4 times.
Wait for the single flash followed by the flickering - enter room temperature in clicks for example 21clicks
Wait for the double flash followed by the flicker - enter step down temperature minus 30 i.e 45 = 15 clicks
Messed it up? Loosen the tail cap, press and hold the power button, retighten (holding down the power button). The light will flicker and ‘strobe’ its reset and try again.