Solar Photovoltaic (PV) Systems, Grounding Electrode System, NEC 2020 - [690.47], (9min:30sec)

  Рет қаралды 9,975

MikeHoltNEC

MikeHoltNEC

Күн бұрын

How do you properly ground a building’s solar photovoltaic (PV) system? It’s not as difficult as you might think. Take a moment to read the text and watch the video where Mike and the PV team explain NEC section 690.47.
This video is extracted from Mike Holt's 2020 Solar Photovoltaic Systems Video Library, for more information visit www.MikeHolt.com/Solar or call 888.632.2633.
For almost 50 years, Mike Holt Enterprises has been providing quality electrical Code training to help electrical professionals learn the Code, prepare for exams, and improve their electrical knowledge. Visit www.MikeHolt.com​ for exam preparation tips and training, instructor and curriculum support, continuing education options, free videos, and graphics, and so much more.

Пікірлер: 16
@FrancisKoczur
@FrancisKoczur Жыл бұрын
Residential transformerless inverters that aren't grounded to neutral have been the standard for a decade. No need for confusing language in the code. Grounded and ungrounded transformer inverters still have their place, but referencing to them isn't necessary. Keep up the good work.
@vassilnikov6814
@vassilnikov6814 Жыл бұрын
What about when the array is on a the roof of a separate building more than 20 meters away from the main building? How do we install SPD devices in such configuration? If the cable trace is that long wouldn't it be inefficient to install the SPD at the box in the main building only? Wouldn't in such case a separate grounding rod and SPD at the separate building with the array be a preferred option?
@gfjardim1983
@gfjardim1983 3 ай бұрын
You can put an auxiliary grounding electrode on the PV array, but the SPD devices should be in your PV combiner box inside your main building, and its grounding wire have to be bounded at the main panel grounding bar.
@christopherworks400
@christopherworks400 Жыл бұрын
I work in solar and I got in an argument with the "electrician" that ground rods are Required by code for ground mount array, even though the metal support was driven in the ground 8 feet. And on top of that he said we need 2. So am I right that they ARE NOT required?
@TheTubejunky
@TheTubejunky Жыл бұрын
Most inspectors say 2 rods. Idk who's right anymore. every engineering line drawing I've seen SHARES a common service ground. That should be all that's needed. You would think right?
@christopherworks400
@christopherworks400 Жыл бұрын
@@TheTubejunky well there was 2 rods for the house, but they wanted 2 more for the array. so there would be 4 total.
@kimandylawrence4199
@kimandylawrence4199 Жыл бұрын
Yes, you are right. They are not required.
@captainjohnmccalpin5161
@captainjohnmccalpin5161 5 ай бұрын
What about grounding requirements for a stand-alone (off-grid) PV system installed in a floating boathouse (covered metal dock on plastic floats, not a houseboat)? There is no utility connection with a grounded service disconnect. What do I need to do to provide a compliant ground for panels, inverter, stand-alone load center, etc.?
@MikeHoltNEC
@MikeHoltNEC 5 ай бұрын
Please send me an email, Mike@MikeHolt.com, with this question so I can work this out.
@captainjohnmccalpin5161
@captainjohnmccalpin5161 5 ай бұрын
Will do!
@georgevan3102
@georgevan3102 Жыл бұрын
What about a line tap pv system. It does not have a ground conductor. Where do you pick up the grounding?
@christopherworks400
@christopherworks400 Жыл бұрын
we crimp on the the ground coming out of the house and add a second rod.
@georgevan3102
@georgevan3102 Жыл бұрын
@@christopherworks400 250.142 have you ever taken this in to consideration?
@kevinthompson4690
@kevinthompson4690 Жыл бұрын
Same here. We were doing small cell 5G sites with 8x8x 12 foot deep concrete encased steel reinforced pole bases with a #2 tinned copper wire attached to the rebar out of the concrete. Ole inspector walks up and says "Wheres your ground rod? gotta have a ground rod". I said really? You think that a 5/8x 8 foot ground rod is required and is gonna do anything? Non educated is what they are.
@WiSeNhEiMeR-1369
@WiSeNhEiMeR-1369 Ай бұрын
now explain how to adapt this too a GROUND-MOUNT Arrays 300' from the House Wiring SYSTEM ... ...
@MikeHoltNEC
@MikeHoltNEC Ай бұрын
Nothing (grounding) is required at all, so you are good.
Grounding, System and Equipment [250.4, 2020 NEC]
33:35
MikeHoltNEC
Рет қаралды 100 М.
3 wheeler new bike fitting
00:19
Ruhul Shorts
Рет қаралды 50 МЛН
Grounding and bonding: Definitions and details
12:42
Eaton
Рет қаралды 82 М.
Grounding, Auxiliary Grounding Electrode [250.54, 2020 NEC]
13:40
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,2 МЛН
How to ensure safe and effective solar grounding
15:56
EnergyUME
Рет қаралды 19 М.
Equipment Grounding for PV Systems
26:14
Penn State Solar Center
Рет қаралды 120 М.
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 5 МЛН
2023 NEC 690.12 Rapid Shutdown with UL 3741
10:12
Mayfield Renewables
Рет қаралды 575