@janosgyerman
@janosgyerman 2 жыл бұрын
there is a macro that creates max and min configurations for the individual components, so you can also run interference detection...yes number of course are important to adjust them
@brentsrx7
@brentsrx7 3 жыл бұрын
Solidworks is incredible
@jaydendavian4410
@jaydendavian4410 3 жыл бұрын
i realize it's pretty randomly asking but does anyone know of a good place to stream newly released tv shows online ?
@dmorgan140
@dmorgan140 3 жыл бұрын
In your first example with the 2 cylindrical shapes, my hand calculation produced a worst case scenario of 350+/- 1.65mm, which is double the amount of tolerance that SolidWorks arrived at. Could the setup be incorrect? Or am I missing something? Please advise.
@monsterjesse
@monsterjesse 2 жыл бұрын
dang, that is so much more simpler than manually calculating. but in your 2nd example if that lip between the orange riser and the purple holder was not present, would calculating the assembly shift with the fasteners be possible? thanks
@chetnaprajapati9483
@chetnaprajapati9483 4 жыл бұрын
how to sync two circle example:- one circle dia75mm and secound circle dia1000mm dia1000mm (1000mm-100mm=900mm) so change dia 75mm change (75mm+100=175mm) mins i one circle dia minuse so secound dia pluse is value how create बहुत बढ़िया पर मुझे ऐसा काम कुछ इस तरीके से करना हो तो कैसे करे कृपया बताये जैसे के एक circle 75mm dia का हे और दूसरा circle 1000mm dia का हे अगर में इन दोनों में से किसी की भी साइज़ बदलता हु तो वो एक दुसरे में pluse minus खुद्ब्खुद हो जाये जैसे के अगर में 75 mm dia में 25 mm जोड़ता हु तो वो dia 100mm हो गया पर जो दूसरा dia जो 1000 mm का हे वो 975mm खुद्ब्खुद हो जाये बस ऐसे कोई भी एक dia अगर pluse होता हे तो दूसरा dia खुद्ब्खुद minuse हो जाना चाहिए और कोई भी एक dia minuse होता हे तो दूसरा dia खुद्ब्खुद pluse हो जाना चाहिए हा पर जितना हम pluse या minuse करते हे उतना ही value एक दुसरे dia में pluse minuse होना चाहिए कृपया करके ये बताये ये कैसे हो सकता हे solidwork में ?
@bobfromtex3196
@bobfromtex3196 3 жыл бұрын
You should always model to maximum material condition.
SOLIDWORKS - DimXpert and TolAnalyst
27:10
GoEngineer
Рет қаралды 37 М.
Tolerance Stackup: Vector Method with GD&T
16:59
R. Dean Odell
Рет қаралды 41 М.
GIANT Gummy Worm Pt.6 #shorts
00:46
Mr DegrEE
Рет қаралды 119 МЛН
Do you choose Inside Out 2 or The Amazing World of Gumball? 🤔
00:19
My Daughter's Dumplings Are Filled With Coins #funny #cute #comedy
00:18
Funny daughter's daily life
Рет қаралды 21 МЛН
Tolerance Stackup: Simple Assembly
7:18
R. Dean Odell
Рет қаралды 55 М.
What is Tolerance stack up analysis | Why Tol stack up analysis
20:04
Mechanical Vault - Kevin Kutto
Рет қаралды 89 М.
#GD&T (Part 1: Basic Set-up Procedure)
15:53
Infinity MFG
Рет қаралды 1 МЛН
From P&ID to 3D Piping to Isometrics: SOLIDWORKS and Smap3D Plant Design
12:27
GIANT Gummy Worm Pt.6 #shorts
00:46
Mr DegrEE
Рет қаралды 119 МЛН