sprinkler system testing procedure | fire sprinkler testing procedure | sprinkler pipeline testing

  Рет қаралды 24,926

Firefighting & Engineering

Firefighting & Engineering

Күн бұрын

Пікірлер: 37
@creativeideascomedyandreal8466
@creativeideascomedyandreal8466 3 ай бұрын
Area, hydrant valve, sprinkler system, aur pump capacity pipeline ka hydraulic calculation pe video banao sir
@FirefightingEngineering
@FirefightingEngineering 3 ай бұрын
Ok.. Let me check
@creativeideascomedyandreal8466
@creativeideascomedyandreal8466 3 ай бұрын
@@FirefightingEngineering area wise midc rahne do ya hospital please video banao aur apna mobile number share kro sir
@creativeideascomedyandreal8466
@creativeideascomedyandreal8466 3 ай бұрын
Kyunki log ye hi kyu pump kitna area hai toh uska hydraulic calculation pe sawal karte hai technical knowledge puchte hai
@SamimSiddiqui-vq7zi
@SamimSiddiqui-vq7zi 3 ай бұрын
सर अगर 50mrt की building हैं और टेरिश पे 3kg प्रेशर चाहिए तो pamp room में कितना प्रेशर सेट करेंगे please answer me please
@FirefightingEngineering
@FirefightingEngineering 3 ай бұрын
7 kg
@amolmahajan6667
@amolmahajan6667 3 ай бұрын
Konse IS code ke anusar hpt testing honi chahiye or kitne pressure pe hona chahiye
@FirefightingEngineering
@FirefightingEngineering 3 ай бұрын
1.5 times of working pressure
@munmunarrannaghor7427
@munmunarrannaghor7427 4 ай бұрын
Ye kya 3 piston ka pump hai ?? Price kya hai
@FirefightingEngineering
@FirefightingEngineering 4 ай бұрын
No idea of price
@mohdanaskhan9872
@mohdanaskhan9872 2 жыл бұрын
On which behalf you are doing testing at 12.5 kg/cm2 ...
@FirefightingEngineering
@FirefightingEngineering 2 жыл бұрын
Which behalf you required?
@mohdanaskhan9872
@mohdanaskhan9872 2 жыл бұрын
@@FirefightingEngineering I want to know the concept why you are doing at certain pressure testing?
@FirefightingEngineering
@FirefightingEngineering 2 жыл бұрын
@@mohdanaskhan9872 it's not certain.. Generally it's sufficient to check pressure at 10 to 15 kg at same floor
@mohdanaskhan9872
@mohdanaskhan9872 2 жыл бұрын
@@FirefightingEngineering If we are testing at 9 kg or 16kg so it will not safe? At there should be a reason behind that why we are doing at certain pressure..
@Asheeeesh34
@Asheeeesh34 Жыл бұрын
@@mohdanaskhan9872 when the sprinkler get trigger by fire the pressure will start dropping...and then after certain pressure drop sprinkler pump will automatically start and it will increase pressure every minute and at one point the line that used to be holding 7 or 8kg pressure in normal condition becouse of sprinkler pump running the Pressure will increase (obviously) and it will definitely reach 15 or 16kg if two or three sprinkler break....
@firetrening2764
@firetrening2764 11 ай бұрын
Sir kis standard m likha pressure kitna hota h plese
@FirefightingEngineering
@FirefightingEngineering 11 ай бұрын
Testing pressure must be 1.5 times of working pressure
@smokejumpers3342
@smokejumpers3342 2 жыл бұрын
Pump ko operate krney r testing ki koi video upload kren aur deluge system detailed video agr ho to vo b upload kren
@FirefightingEngineering
@FirefightingEngineering 2 жыл бұрын
We will look after your suggestions sir
@smokejumpers3342
@smokejumpers3342 2 жыл бұрын
Info outclass Hy but phone ka angle br br video ko dstrb kr rha Hy..Phone kisi 1 angle pe set kren
@FirefightingEngineering
@FirefightingEngineering 2 жыл бұрын
We will make video on this
@sajeed_aly2661
@sajeed_aly2661 Жыл бұрын
Sprinkler & Hydrant ka operating pressure Kitna hota hai please bataye
@FirefightingEngineering
@FirefightingEngineering Жыл бұрын
It's depend on building height dear
@creativeideascomedyandreal8466
@creativeideascomedyandreal8466 3 ай бұрын
​@@FirefightingEngineering kaise nikale operating pressure
@TechRBL
@TechRBL 3 жыл бұрын
What is worked pressure
@FirefightingEngineering
@FirefightingEngineering 3 жыл бұрын
2 to 5 kg/cm².
@ferozhassan3199
@ferozhassan3199 9 ай бұрын
پریشر گیج کولیبریتمٹڈ ہونا چاہیے؟
@FirefightingEngineering
@FirefightingEngineering 9 ай бұрын
?
@mohdmujahid4506
@mohdmujahid4506 3 жыл бұрын
What is standing pressure of water in fps system
@FirefightingEngineering
@FirefightingEngineering 3 жыл бұрын
2 to 5 kg/cm2
@Asheeeesh34
@Asheeeesh34 Жыл бұрын
Fps? Psi u mean?
@komalsharma6833
@komalsharma6833 3 жыл бұрын
❤️❤️❤️
@sydkhan3643
@sydkhan3643 3 жыл бұрын
Oooohhhhooooo
Fire Sprinkler system | Firefighting lesson 6
13:56
AMJ Engineering
Рет қаралды 319 М.
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 22 МЛН
Main Components of Fire Fighting Pump Room Part 1 in Urdu
13:48
Tanweer Ahmed
Рет қаралды 167 М.
MEGAFLEX High Performance Flexible Fire Sprinkler Drop
3:38
Fire Fighting Pump Room | Firefighting Fire Pumps in Urdu/Hindi
16:11
Tanweer Ahmed
Рет қаралды 354 М.
How to Make a Real Diamond - (Not Clickbait)
8:51
JerryRigEverything
Рет қаралды 1,3 МЛН
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 22 МЛН