Sprinklers Decoded #1 - Standard Coverage Fire Sprinkler - Spacing, Area Tutorial

  Рет қаралды 27,434

BIMitUP

BIMitUP

Күн бұрын

Пікірлер: 42
@andreaguadarrama9969
@andreaguadarrama9969 2 жыл бұрын
Perfect mix of modern BIM approach and field experience. Thanks! Great job
@bimitup
@bimitup 2 жыл бұрын
Thank you Andrea
@dag1024
@dag1024 3 жыл бұрын
Great topic. Can't wait for #2. Thanks!
@bimitup
@bimitup 3 жыл бұрын
Well Daniel, stay tuned and buckle up =)
@josesol1478
@josesol1478 3 жыл бұрын
IT SEEM TO ME VERY INTERESTING
@bimitup
@bimitup 3 жыл бұрын
Stay tuned for more videos on this
@edsoncuevas7652
@edsoncuevas7652 Жыл бұрын
Thank you so much for posting this, I’m a 2nd year apprentice in the union and our class is once a month but our instructor goes over stuff way too fast and I am a slow learner so this helps me a lot
@bimitup
@bimitup Жыл бұрын
Glad it was helpful!
@gizwiz3482
@gizwiz3482 Жыл бұрын
I understand now! the way you explained it and showed it was perfect
@bimitup
@bimitup Жыл бұрын
I'm glad it was useful and you liked it.
@larry6510
@larry6510 3 жыл бұрын
Great Alex!! thanks for your time
@bimitup
@bimitup 3 жыл бұрын
Hi Larry. I'm glad you enjoyed it. Stay tuned for the pump room webinar, and sign up if you haven't =)
@beatrizsilvaprieto
@beatrizsilvaprieto 3 жыл бұрын
very clear, important and useful information, we are learning a lot with your videos Alex, Thanks
@bimitup
@bimitup 3 жыл бұрын
You are welcome Beatriz.
@shamsulbahariazraai9560
@shamsulbahariazraai9560 Жыл бұрын
Thanks Alex . Good presentation
@bimitup
@bimitup Жыл бұрын
Glad you liked it!
@andreinaruizrequena8643
@andreinaruizrequena8643 3 жыл бұрын
Great video! Very useful
@bimitup
@bimitup 3 жыл бұрын
Thank you Andreina. I'm glad you found it useful.
@natillitafull
@natillitafull 3 жыл бұрын
Aha! I will use it to plan my RCPs
@bimitup
@bimitup 3 жыл бұрын
Great! Make sure to leave some work for MEP consultants...hope you don't know hydraulics lol =P
@mikeportuondo7786
@mikeportuondo7786 3 жыл бұрын
Love it!
@bimitup
@bimitup 3 жыл бұрын
So glad!
@birosca8
@birosca8 3 жыл бұрын
Amazing content as always!!! Thanks for sharing. Keep up the good work!
@bimitup
@bimitup 3 жыл бұрын
Thanks Stuard. I'm glad you liked it.
@orlandorodriguez9245
@orlandorodriguez9245 2 жыл бұрын
Nice video! I would be interested in the small room exceptions! Great job!
@bimitup
@bimitup 2 жыл бұрын
Hi Orlando. It's on the list. Stay tuned =)
@adelalvarez1130
@adelalvarez1130 3 жыл бұрын
This Is great idea
@bimitup
@bimitup 3 жыл бұрын
Thanks Adel
@fabiolasilva7603
@fabiolasilva7603 3 жыл бұрын
Nice video!
@bimitup
@bimitup 3 жыл бұрын
Glad you enjoyed it
@andreaguadarrama9969
@andreaguadarrama9969 3 жыл бұрын
Thanks a lot!!!
@bimitup
@bimitup 3 жыл бұрын
You're welcome!
@LakersNotFakers4
@LakersNotFakers4 2 жыл бұрын
thank you
@bimitup
@bimitup 2 жыл бұрын
You are welcome Pat!
@app-o-matix
@app-o-matix 7 ай бұрын
I know this is a couple of years old, but I’m not understanding why there needs to be 4 sprinkler heads on each branch for the normal exposure example. I’m starting with the room 26.625’ left-to-right and 26.917’ top-to-bottom. It seems to me the way to enable the maximum sprinkler head spacing (S) is to minimize the branch spacing (L) since S = 130 / L (smaller L means larger S). The way to minimize L is to divide the room width by 2, which gives a branch spacing of 26.625’ / 2, so L = 13.3125’. Any smaller and the branch-to-wall distance times 2 would be larger and used instead for L. With an L of 13.3125’, the max sprinkler head spacing becomes 130 sq ft / 13.3125’, so max S = 9.765’. If I distribute 3 sprinkler heads along each branch, I can determine a good spacing by dividing that room dimension by 3. So 26.917’ / 3 means S = 8.972’, which is greater than the 6’ minimum spacing and less than the 9.765’ maximum spacing needed to stay within the 130 sq ft maximum area when the branch spacing is 13.3125’. Spacing from the first and last heads on a branch to their respective walls is 4.486’ (1/2 of S, so 8.972’ / 2). I’m not trying to pedantic, I’m really trying to understand and I’m not sure my math is correct or if there is something I’m not accounting for.
@bimitup
@bimitup 7 ай бұрын
Thanks for the comment. And, no worries, I always assume people are genuinely trying to understand. A couple of notes: This is meant to be a simple introduction and there's many ways to lay out sprinklers (depending on several factors (out of the scope of this free video). There was also a harsh video cut at 15:11...which I realized several months after uploading the video =( I'm assuming, "normal exposure" you mean Ordinary Hazard (since you mention 130 - 130sf max per sprinkler). I think the confusion comes from your statement "minimize the branch spacing L". Actually, most of the time, you want to keep L (distance between branch lines) as large as possible so that you minimize the number of branches (fewer large fittings, etc.) (4:10 and 11:32). Hence the initial 14' separation (we want to keep 2 branches only). However, the distance between sprinklers cannot remain at 14' (like in the previous example for light hazard). So, I tried keeping that distance as 10'. However 130sf / 14ft = 9.286ft, so they cannot be spaced 10ft either, it has to be even smaller... Now, if you pause the video at 15:08, and remember the 9.286ft max distance... 9.286/2 = 4.643ft, and the distance from the wall is 4.578. So the top sprinkler would barely comply (again, assuming the video frame of time = 15:08). HOWEVER, if you move the south sprinklers up 2' (because remember, 10' between sprinklers is too much, so you have to shrink to 8'), then that distance of 4'-4 1/16" shown on frame 16:51 becomes 6'-4 1/16", which when multiplied by 2, exceeds the maximum distance along branch line. Just as a word of caution, even if the south sprinklers were at the same situation as the north sprinklers (barely making it), I, as a consulting engineer wouldn't keep it since the ceiling could shift 1 inch and then everything is out of compliance (not to mention any changes with lights, diffusers, detectors, etc.). (As a contractor you can push a little more, because by the time they get the project the project is a little more "solid"). I really hope this clarifies. Thanks for watching and good luck. Also, keep in mind that depending on workmanship, type of fittings and site conditions, it might be beneficial to "revert S and L", and remember, your layout has to be "balanced (symmetrical and pretty), so that Architects like you too =)
@EricPham-gr8pg
@EricPham-gr8pg 9 ай бұрын
Should water temperature and room temperature be considered for efficiency...also should mix type of fire class like gas station out door fuel fire and foam ratio per area
@bimitup
@bimitup 9 ай бұрын
Hi Eric. Water temperature and room temperature have no direct effect on the sprinkler spacing. Sprinkler spacing is a function of the "fire occupancy hazard". If you have a gas station you have a more demanding fire occupancy hazard than an office, so your sprinklers would have to be spaced closer together and you would be required to use a higher water discharge density (gpm/sf).
@robertbiol5983
@robertbiol5983 2 жыл бұрын
What is the standard distances if the sprinkler heads upright position under the beam?
@bimitup
@bimitup 2 жыл бұрын
There are several factors that can affect that. The 1st one is Occupancy Hazard. If you are in a Light Hazard space, the maximum spacing is 15' and the maximum protection area allowed is 225sf. If you are in an Ordinary Hazard I, then max spacing is 15', but max area 130sf. There are also obstructions, etc. Check NFPA 13
@PekeKnuckles
@PekeKnuckles 8 ай бұрын
what in the world happened at 15:15?
@bimitup
@bimitup 8 ай бұрын
I had to make a harsh cut and paste two different videos together, but the point remains valid. Thanks for watching =)
Sprinkler Arm Over in Revit (Return Bend) Tutorial
10:27
BIMitUP
Рет қаралды 3 М.
Why Does Fire Sprinkler Spacing Matter?
9:19
MeyerFire
Рет қаралды 8 М.
Accompanying my daughter to practice dance is so annoying #funny #cute#comedy
00:17
Funny daughter's daily life
Рет қаралды 15 МЛН
How To Choose Mac N Cheese Date Night.. 🧀
00:58
Jojo Sim
Рет қаралды 94 МЛН
Fire Sprinkler system | Firefighting lesson 6
13:56
AMJ Engineering
Рет қаралды 314 М.
Plotting The Design Area in a Fire Sprinkler Layout
11:37
H. Machacon Mechanical Engineering
Рет қаралды 7 М.
ESFR Obstructions - Changes to NFPA 13 2022 Edition
52:09
Reliable Automatic Sprinkler Co., Inc.
Рет қаралды 3,4 М.
Sprinkler Installation Requirements in NFPA 13
1:47:24
Sprinklermatic
Рет қаралды 135 М.
Ordinary Hazard Occupancy NFPA 13 Fire sprinkler head spacing
5:13
Sprinkler Systems for Firefighters
13:09
Bedford Fire Department
Рет қаралды 144 М.