***Square D QO Breaker Panel Recall*** How to Fix it Yourself!

  Рет қаралды 8,176

Ben's Solar and Battery

Ben's Solar and Battery

Күн бұрын

Link to Schneider's recall information
www.se.com/us/...

Пікірлер: 14
@offgridwanabe
@offgridwanabe 2 жыл бұрын
Cheers I always check those "factory" screws for tightness on most electrical stuff.
@jeffmaling9577
@jeffmaling9577 2 жыл бұрын
Thanks Ben...good reminder that ensuring proper torque on critical fasteners is always part of a job well done. Working at IBM, I saw surprising examples torque failures causing burned up breakers. In those cases, the fail was usually over-torqueing. When over torqued, the lugs would crush the metal in the conductors, and over time electromigration from the crush site would end up loosening the lug and causing it to get higher resistance. This leads to overheating failure...burned up conductor insulation, smoke damage, and a significant safety hazard. So too loose and too tight are both problems. What's needed is just right....which can only be done with a torque wrench. This is why every electrical device with a lug has torque specs printed on it.
@wd9dau
@wd9dau 2 жыл бұрын
Never trust an electrician with no eyebrows!
@djea3589
@djea3589 Жыл бұрын
Get some RED or ORANGE fingernail polish (pumpkin orange is usually very cheap after halloween). Use the polish on the threads after torque set. If the screw ever changes then the polish will flake and or show a crack. This is a this is a "tamper-proof" seal method used in industry in quality assurance all the time. Markers only show that someone marked it for some reason, lacquer seal shows tamper and change as well.
@meganwinters5163
@meganwinters5163 2 жыл бұрын
Thank you, Ben 🙏. I knew about the recall, but now I know the fix. So very much appreciated 🙂👍!
@faithneswick347
@faithneswick347 Жыл бұрын
So if they're not loose but I can still tighten them should I tighten them with the torque wrench until I can't anymore?
@zakboza852
@zakboza852 Жыл бұрын
"Small star bit" = T20
@WiSeNhEiMeR-1369
@WiSeNhEiMeR-1369 Жыл бұрын
THANKS COOP ...
@RJ-cc1fz
@RJ-cc1fz 2 жыл бұрын
Simple enough
@fisherus
@fisherus 2 жыл бұрын
Ben, where do you go to find the panel model numbers that need this done?
@benssolarandbattery
@benssolarandbattery 2 жыл бұрын
Hi Craig, I left a link in the description that should have all the info you need.
@beckfordelectrical
@beckfordelectrical 2 жыл бұрын
What about that xw pro
@benssolarandbattery
@benssolarandbattery 2 жыл бұрын
Fired it up last night! Testing should commence this weekend.
@beckfordelectrical
@beckfordelectrical 2 жыл бұрын
@@benssolarandbattery have recently gotten one but Did get the chance off testing it because am abroad and low battery
Attention! Square D QO Recalls Electrical Panels
3:23
abrelectric
Рет қаралды 14 М.
Square D - Plug On Neutral
30:34
Square D
Рет қаралды 27 М.
Worst flight ever
00:55
Adam W
Рет қаралды 27 МЛН
Watermelon magic box! #shorts by Leisi Crazy
00:20
Leisi Crazy
Рет қаралды 23 МЛН
А ВЫ ЛЮБИТЕ ШКОЛУ?? #shorts
00:20
Паша Осадчий
Рет қаралды 9 МЛН
The day of the sea 😂 #shorts by Leisi Crazy
00:22
Leisi Crazy
Рет қаралды 2,1 МЛН
Arc Fault Breaker Keeps Tripping! How To Fix It!
16:31
Benjamin Sahlstrom
Рет қаралды 96 М.
Challenger panels are fine
5:10
Structure Tech Home Inspections
Рет қаралды 7 М.
Why Neutrals & Grounds are Connected in a Main Panel
20:13
Benjamin Sahlstrom
Рет қаралды 1,5 МЛН
Sol-Ark 12k Kept Shutting Down. Can the SMALLER Schneider Handle it?
12:09
Ben's Solar and Battery
Рет қаралды 17 М.
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,5 МЛН
How to Install a Subpanel
15:35
Got It Made
Рет қаралды 1,4 МЛН
5 Common Electrical Panel Mistakes
4:38
Electric Pro Academy
Рет қаралды 236 М.
Which Splicing Device is Best?  Push Ins Vs. Wago Vs. Wirenuts
13:06
How To Home
Рет қаралды 1,4 МЛН
Worst flight ever
00:55
Adam W
Рет қаралды 27 МЛН