i'm expecting mondays patch notes is gonna read "bolts on liquid pipes now line up" 😄
@cowsareevil75146 ай бұрын
Mismatched bolts cause pipe failure.
@zairev34386 ай бұрын
If not, i am gonna start an uprising.
@novoca1n36 ай бұрын
Love the OCD comeback. Brilliant!
@Touay.6 ай бұрын
indeed, i was going to post the same.
@TminusDoom6 ай бұрын
I enjoy all your series, a lot of fun to watch. I only have one small gripe. In a lot of your videos there is an audio clipping that is pretty jarring while wearing headphones. In this video it happens at 9:40 a couple times and then at 18:20 , 36:12 , 46:23 for example.
@danielmills79726 ай бұрын
Checklist for background check/fixes: when you disconnected the line to the CO2 tank for your green house the IC chip might need to be re-connected to it. That might be why you have your always-on blue light there. Also: thank you for the excellent work background noise. Keep innovating!
@zairev34386 ай бұрын
You got temperature problem because you messed with the OCD natural order. Dont mess with the OCD natural order, or things will start to explode. Thats common sense :p
@walterverlaan12866 ай бұрын
LOL
@cowsareevil75146 ай бұрын
"Danger" is the appropriate alarm for OCD violations
@mwwoggy6 ай бұрын
Your warning system is awesome! Well worth the time you spent on it.
@acanadianderg40356 ай бұрын
I wonder how much power you could get back by putting a turbine in front of the liquid drains
@dan29546 ай бұрын
Thanks for another great episode of this terrific game!
@TianarTruegard6 ай бұрын
I've been using a gas intake system on Mars that's similar to Cows'. I'm running into the issue of it not keeping up. I may have to go crazy with the intake vents and drains as well. I've been messing around in a creative world, trying to figure out the best setup to separate the Co2 and pollutants out for use in my base. I'm currently using a separate filtration unit for capturing Co2, but would be so much nicer if I could use phase change. No more printing filters! The only thing I can come up with is continuing to collect gas at night, then separating the condensed Co2/X mix and heating it until the Co2 starts evaporating from the pollutants. Pressure would keep the pollutants as a liquid which I could separate off as a liquid into a different tank.
@marcusw866 ай бұрын
In addition to text panels, I think they could use control consoles, for communications and operations centers.
@cowsareevil75146 ай бұрын
CCTV for appreciating multiple explosions from you control room.
@dunneemofozilla57186 ай бұрын
Between however many days of stale farts in your suit, a mountain of poo in the greenhouse (more like brownhouse...) and a pile of rotting vegetables in the bedroom this game ought to be called Stationnose not Stationears
@cowsareevil75146 ай бұрын
I hope are qualified for dad jokes like that.
@CrinosAD6 ай бұрын
AAAAAAAAAAAAAAAAARGH..... Dammit... bolts on pipes 🤣 I regret mentioning the heavy cable junctions boxes 😝
@inneedofmedication6 ай бұрын
Pretty sure the air tank problem is because of the temperature. It stays around, -8C to -10C. I've found -14C and below makes the CO2 draining far quicker. I believe it's so warm in the tank because the tank was nearly full so it took in warmer atmosphere and shut off before the necessary cold atmosphere could be taken in. Then when the liquid boils off it warms the gases in the tank too, creating a double whammy. There's few quick options. You could set the vents to turn on later, thus intaking cooler air. Trading off quicker CO2 bleed time for less time taking in atmosphere. You could allow the room cooling pumps to turn on with liquid/gas CO2, but not pollutant, still in the line. It's like a hybrid system of what you're starting to experiment with. I worry that with the plants and nutrition mod and the setup to pull water out of the air, it might put a lot of CO2 in your water line. You could create an air tank "cushion," so the vents can turn on up to 20MPa, but can stay on up to 25-30MPa once turned on. Preventing the vents turning on/off rapidly at 20mpa, also allowing a bit more air in the air tank, so once full it may not turn on every night. You could keep up to 20MPa the same and set up a PID so from 20MPAa to 30MPa, the vent will turn on and off later and later, creating a colder air tank once it crosses 20MPa. You could capture the liquid CO2/pollutants and run them through a heat exchanger, or multiple, to cool the air tanks. Recapturing some the lost cold due to phase change. I will get you to use liquid cooling yet, I swear!
@cowsareevil75146 ай бұрын
I could use the captured liquid in an evaporator to cool the breathing gas.
@walterverlaan12866 ай бұрын
Excellent episode, as usual.
@NitroEvil6 ай бұрын
Haha pipe OCD what have you done!
@TianarTruegard6 ай бұрын
Pipe OCD caused the alarms I think. ;)
@witgangyounotube2876 ай бұрын
have a base on vulcan with 4 sets of 5 stage cooling setups(H2O to N20 to Pollutant and another pollutant stage and finally a volatiles stage) been using it to cool down about 130k mols of volatiles and it took quite a while to get to -100 or so until it came to my mind that it might be faster to cool stuff down by just running it trough a few direct heat exchangers dumping heat in each stage starting with the hottest stage that is below the temperature of the gas i want to cool down. managed to get 25k joules of cooling using that instead of the 10 k joules just cooling from the cold end and all that using just about 2.4 kw of power which seems pretty efficient compared to AC's
@Touay.6 ай бұрын
Is it time to panic? yes, yes it is!
@johnturner95466 ай бұрын
What happened to bases 1 through 12??? What are they not telling us?
@Sworn9736 ай бұрын
35:15 wtf?! Why, WHY! NOOOOOOOOOO 🤣
@pvstiphout6 ай бұрын
You can't trigger my ocd with some commands on bolts. I already check the cables and pipes. Who has ocd now, haha. 😂
@marcusw866 ай бұрын
Cow your hilarious watching! Haha
@keyogen4 ай бұрын
I tried copying your air system but found using the daylight sensor to be a pain. So, I switched it to a temp sensor. So when the temp gets to 0, it turns on. My system is smaller, so I pump it to 25Mp and let it drop 23Mp to give it time to let the liquids out at night.
@danielmills79726 ай бұрын
I know it's a rip on ShadowDrake, but seeing the trade tester rig there, I wouldn't mind seeing a competitive race between you, Shadow, and Elmo for something like "first to $1 mil" on a planet. (If you're looking for content ideas)
@cowsareevil75146 ай бұрын
I dont have the patients for the RNG of trade.
@samuraidriver4x46 ай бұрын
Brb ripping up all my pipes, literally unplayable 😮 Just kidding, did know about the pipes bit didn't know about the heavy cables. Cooling the cooling/air tank down more should help with faster condensation of the co2, the colder it is the faster it you can get rid of polutant and co2. You also need less gas to cool down the base if its colder. The tank was colder then it is now if i recal correct and that might be the change?
@cowsareevil75146 ай бұрын
I think the celestial fix has messed with the night temperatures. I might have to change my on times for colder gas.
@samuraidriver4x46 ай бұрын
@@cowsareevil7514 good point, glanced over that in the patch notes but didn't think to much of it.
@magnusthor6 ай бұрын
how you done the writing on the wall which says "Mars Base 13" ?
@kennydewilde7826 ай бұрын
can i ask how to change the color on lights like for a battery under 20% is red and so on cant make it work
@warmadmax6 ай бұрын
*Triggered!* 🤣
@Engineer_KO6 ай бұрын
I have no idea what you are doing. Can you make a video where you explain this system, please?