Stationeers No AC Venus 12 Rules are meant to be broken

  Рет қаралды 4,263

Cows are evil

Cows are evil

Күн бұрын

With the completion of the cool room I now need to get the cool distributed around the rest of the base. The existing uncontrolled cooler has to be removed as the room gets too cold and a regulated cooler put in place. To do all of this I will need to enlist the help of that who will not be mentioned (don't look at the thumbnail).
30 days to set up and expand the cooling to be fully functional ready for pressurising the rest of the base. Of course it would take longer if you were doing all of the mining and not cheating like I was. If you were doing a survival, it could be better to set up AC units sooner to help with regulating the temperatures during the setup but everyone has their own way of doing things.
But that is the end if this series and AC units are still effective on Venus with a little help from the winterspawn.

Пікірлер: 43
@jurgenbreitag858
@jurgenbreitag858 Жыл бұрын
Your Bluehouse is still getting to cold. Because Your pollutant is -25Celsius at end of the video, so the ac in bluehouse lost alot of it´s efficiency teh temperature was only 14Celsius. I would suggest you build a pipe heater for your pollutant tank with a IC to heat it to 0Celsius. It sucks a bit energy at the moment but as the Base grows and you cool more rooms the IC shut the pipe heater only on if needed. Or to save Energy use Heat of Venus and use big Radiator with pump and one way valve and an IC. I think so you could hold the efficiency high on all AC Units.
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
I would have to argue that if my coolant line is at -25 then the efficiency of the bluehouse is working just fine. As I expand the base and start cooling more rooms the temperature of the pollutant will rise.
@jurgenbreitag858
@jurgenbreitag858 Жыл бұрын
@@cowsareevil7514 you understud me a litte bit wrong the bluehouse is efficient, it is cold, only the AC in the room lose it's efficency and is not able to hold your set 20 degree. IT was only able to hold 14 degrees, because of the coold Coolant. But still nice Work and for me ist IS a No AC Run. You use them only as Transport medium Not as a real AC.
@kyleallred984
@kyleallred984 Жыл бұрын
It would be cool to see a series with the atmo mod Elmo made.
@Touay.
@Touay. Жыл бұрын
What do we think of the farming updates that just dropped?
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
Need to some testing. There may be some potential for shenanigans.
@mwwoggy
@mwwoggy Жыл бұрын
not 1 but 2????? I think you probably got everyone at Rocketwerks a day off - "Mick had to use an aircon - they're not totally useless!"
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
This was the plan from the start. AC is part of the solution, not the whole solution. AC only on Venus is almost useless. AC+winterspawn is very good on Venus.
@ts_vexx6883
@ts_vexx6883 Жыл бұрын
Rule breaker! :D :D
@gonzalomartinez6219
@gonzalomartinez6219 Жыл бұрын
Do you think you could accomplish this after the farming update?, I am doing right now a winterspawn farm and they are taking foreeeeeever to grow, they are surviving because I am babysitting the greenhouse with a portable AC, lots of days ingame and they still didn't generated cold.
@lionllew6601
@lionllew6601 Жыл бұрын
You can't call it a no ac run now. 🤦‍♂️
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
True, But I think I met that challenge in the last episode so now I wanted to show how I would do it without limitations.
@lionllew6601
@lionllew6601 Жыл бұрын
@@cowsareevil7514 that is fair of you in all honesty, it is a good way to store the excess cooling. I can think of other ways to keep the 20c throughout the base, and ways to make enough heat to keep your plants alive if needs be and really, outside of keeping plants and base to a habitable temperature, what other apications actually are there for having supercooled gas in the game? I mean it's not that useful, what needs to be that cold (under 0)? Having a buffer is... Well... Cool, but you can do that with mols of water at 20c, a huge tank of x at 20c in a frame enclosed room filled with x to 100000MPA at 20c...🤷‍♂️ I had higher expectations of you Mick! Should have stuck to your guns, (but I know you can laugh in the face of some people the way you have done it, regardless, so I forgive you nethertheless.)
@TylerPederson
@TylerPederson Жыл бұрын
Just rename the thing to "heat pump" and you're golden.
@pvstiphout
@pvstiphout Жыл бұрын
Lovely serie Mick, I was starting to miss Wilson. Good for him to show up to lend a hand.
@chriswoodend2036
@chriswoodend2036 Жыл бұрын
So mentally stepping through this I feel like I'm missing something. You're trying to keep two rooms currently connected to each other with passive vents at ~20c and have a literally limitless pool of thermal energy outside. Why not connect a gas to gas heat exchanger to pipe bridging the two with a valve to control if the gas can circulate to the heat exchanger? The only problem I can see is excess gas between the heat exchanges and the control valve making the gas in the pipe excessively hot but you could void it with a backpressure valve easily enough. I'm not sure what I'm missing, what's the virtue of the cold tank when ultimately all you need to do is bring in heat?
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
Heat transfer will occur through the heat exchanger but ti is limited by the the temperatrue difference between the rooms. The AC will force the heat transfer much faster. When cooling down new rooms the coolant line can rise to over 100C wihtout causing problems to the other connected rooms except for some loss of efficency. Also storing all of the cold in the tank will allow for a surge of heat when emergency cooling after accident.
@chriswoodend2036
@chriswoodend2036 Жыл бұрын
@@cowsareevil7514Appreciate it. I didn't explain my heat sinking idea correctly, I was suggesting that you could us the exterior gas to heat the combined interior gas, but having the tank as a means of dealing with surge demand would, in and of itself, justify the method you're using.
@crankreid
@crankreid Жыл бұрын
54 mins in, only realised what the title meant :D bloody AC
@ConnorArchibald
@ConnorArchibald Жыл бұрын
I haven't read enough about the newest plant systems but it would be so cool to have a long term experiment that, over time, exposed the plants to more and more heat to the point that eventually they can be planted in open Venusian atmosphere XD
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
It is a new game mechanic so there will most likely be some impossible inventions to be made. Can you change the survival temperatures enough to get the winterspawn and hades to power a Stirling generator for free.
@aarons7615
@aarons7615 Жыл бұрын
you could have just used a digital valve in your passive radiator system in the plant room to turn on and off the cold air.. its the setup i used in my last base and worked perfectly. you could even use the same setup as a heater too.
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
I was going to do that but this just allows for faster heat transfer.
@TianarTruegard
@TianarTruegard Жыл бұрын
Digital valve and passive radiator system works great on Mars for cooling. You just have to take into account the slow cooling time when programming your cooling system. I've also messed around with just leaving radiators on the outside of my base piped directly inside with a passive vent open to the inside, letting inside air circulate to the pipe outside with the radiators on it. If you get the number of radiators right it works fairly well in cooling a greenhouse. Though the temperature does swing around quite a bit.
@TianarTruegard
@TianarTruegard Жыл бұрын
Has anyone succeeded in using water as a thermal heatsink? I know it has some limitations in that you have the 0 degree freezing point (eventually) and the 100 degree boiling point (eventually). I'm experimenting with it on mars to regulate my base's main air mix tank temperature. I have an extendable liquid radiator that I have IC controlled to deploy when the water tank temperature gets above a certain setpoint and the outside temp is below the tank's temperature. It also doesn't deploy when the tank's temperature is at or below 5 degrees C so I don't cause the water tank to freeze. I'm kind of wondering if I'd be better off using a gas like Pollutants as the coolant medium so I can have a larger coolant temperature range. I haven't tried those cold plants at all, my Venus attempts haven't lasted long at all as the environment is so harsh I keep dieing. The suit dumping O2 to cool you is really annoying, suit needs a proper cooling system.
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
On Mars I just have a pipe pressurised with atmospheric gas with some radiators facing inside and some outside. The base gets warmer during the day and cooler at night. It is enough to get rid of the excess heat from the equipment but not enough to freeze the base. Experiment by adding or removing raditors to find the right balance.
@ScreamingDoom
@ScreamingDoom Жыл бұрын
I think the AC unit needs to be renamed to Heat Pump. That's a more accurate name for what it actually does. A possible improvement would be to add a gas-to-gas heat exchanger between the coolant pipe and the waste gas pipe. Since most gas in the base is going to go through there anyway and you're pulling in ultra-hot Vensuian CO2, precooling it all would be a big benefit. It doesn't need the speed of a heat pump, so just having the energy cheap heat exchanger would be useful. Precooling the CO2 this way would also help keep the greenhouse from overheating (at one point it reached 41 degrees!) when levels drop very low.
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
Now that the cold gas is available there are many ways to use it. I was going to do something similar in using it to regulate the gas storage on the roof. The filtration IC is already programmed for cooling so it would be simple to set up.
@Shiva1945
@Shiva1945 Жыл бұрын
Ok, been running on Venus for a while. Everything when South with it new updates what to do. Oh, I know what would Mick do. He has a solution, thank you man. A savior.
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
To be honest, this wasn't the solution I was going to do. I had something much more complicated planned until I thought of using the AC as a heater in the bluehouse. So this solution is about 2 days old and a lot better than what I had planned.
@m109rjohno
@m109rjohno Жыл бұрын
Cheers Mick
@lumirbaca1831
@lumirbaca1831 Жыл бұрын
58:57 who said conditioners are useless?
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
The winterspawn are doing all of the work, the AC is just taking all of the glory.
@jojoskunk
@jojoskunk Жыл бұрын
The plants dont need to be replanted anymore. After they been harvested now they re-fruit every X days depending on the plant. Faster then regrowing them from a seed.
@destari5917
@destari5917 Жыл бұрын
not all plants are perennials, some still need to be replanted.
@jojoskunk
@jojoskunk Жыл бұрын
@@destari5917 Thats the word, perennial and ya a notice it not long after.
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
This is going to make the Harvie code a lot more complicated.
@Gozza71
@Gozza71 Жыл бұрын
Now you just need food.
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
I can plant a potato. That is all the food you need.
@BlackIcePanther
@BlackIcePanther Жыл бұрын
I'm not to good at coding but for your Workshop Item "Suit" and the code you used for your suit in the first few videos of this run. Where would you put in the filtration on/off range?
@cowsareevil7514
@cowsareevil7514 Жыл бұрын
The one on the workshop does not do that.
@Daednumai
@Daednumai Жыл бұрын
Great series Mick :) How about another Space Engineers one again soon(ish)?
Stationeers Farming with the improved LArRE
1:01:12
Cows are evil
Рет қаралды 2,4 М.
Stationeers Building a rocket without using the instructions.
58:18
How Strong is Tin Foil? 💪
00:26
Preston
Рет қаралды 128 МЛН
АЗАРТНИК 4 |СЕЗОН 3 Серия
30:50
Inter Production
Рет қаралды 1 МЛН
How To Get Married:   #short
00:22
Jin and Hattie
Рет қаралды 22 МЛН
Стойкость Фёдора поразила всех!
00:58
МИНУС БАЛЛ
Рет қаралды 3,5 МЛН
I Built a Fully Vertical Factory That's a 100% Total Nightmare - Satisfactory
28:57
Stationers larre Dock
1:25:19
blidis
Рет қаралды 22
Speedrunning GFG on Vulcan - Stationeers
2:51:38
Elmotrix
Рет қаралды 18 М.
Stationeers Venus Getting Started EP04 - I Have the POWER!
44:47
Rimworld Organ Harvesting (LIVE)
3:36:56
The Spiffing Brit
Рет қаралды 3,3 МЛН
Want Denuvo in Your Game Mods? - WAN Show September 8, 2023
3:45:07
Linus Tech Tips
Рет қаралды 1,5 МЛН
How Strong is Tin Foil? 💪
00:26
Preston
Рет қаралды 128 МЛН