It helped me a lot while building an apartment on the farm! Thank you!!
@IslamYunusov8 жыл бұрын
Thank you so much for this video. For those of us who happen to get to these technologies now only - value this opportunity to learn so much - you would not believe!
@rickymcmillian65534 жыл бұрын
Very informative video, well presented. Thank you
@makaveli2tt3 жыл бұрын
This helped a lot. Thanks for sharing
@margeritadonithorne85493 жыл бұрын
Very informative. Thank you for sharing.
@sarahbunhu24612 жыл бұрын
I appreciate your video. Thanks 🙏 have learnt a lot
@Kjhdfyy6 жыл бұрын
very good Installation technique ... thanks for your efforts.
@JavierOropeza084 жыл бұрын
I did not know that the mason also installed the door frames, this order seems odd to me, but I don't know any better. thanks for this.
@mikefournier82635 жыл бұрын
Good vid ,sorry to see the OSHA bust on the mason's backwards hard hat in your professionally done video , oh well ,but I have a great tip ,since I have installed thousands if masonry frames ,when the frame is set ,I always install the rubber mutes ,or silencers ,as the mortar or grout added will seep out the silencer holes ,and drilling will be required later to install the silencers ,I remove them when I remove the braces ,as they will interfere with the painting of the frames ,but saves time and labor !! I also keep 4'x8' x 1/2" thick styrofoam sheets on hand to cut into stop width strips ,and apply with silicone caulking where any surface mounted hardware re- reinforcements are ,this does not impede the frame grouting ,and saves your drill bits when hardware time comes !!
@nunyabusiness8965 жыл бұрын
While I don't know OSHA codes to the letter to know for sure if this is a violation or not, I do know that some hard hats are made specifically to be worn backwards as forward brims can interfere in tight spaces and some workers would prefer their neck shielded from the sun when working outdoors.
@mikefournier8263 Жыл бұрын
@@bricklayer621 wrong
@mikefournier8263 Жыл бұрын
@@nunyabusiness896 wrong
@nunyabusiness896 Жыл бұрын
@@mikefournier8263 Eat sht fcker I've seen them with my own eyes.
@aclshumway2 ай бұрын
The problem with thinking you're always right and everyone is wrong is that you look like a complete fool when you are wrong. www.osha.gov/laws-regs/standardinterpretations/2011-05-09
@jchristopher43106 ай бұрын
SDI's your white paper "the Risk of Grouting Steel Frames" also says grouting is usually not necessary for masonry construction. However if done properly it will not cause any issues w/ the frame. But when not coordinated properly a thin slurry is often used & that excess water often causes rust.
@NitroXpress3 жыл бұрын
I´m a little confused - do I have to check for plum, level and square?
@zakbzak73 жыл бұрын
Yes. And brace it off securely with 2x4s. And spacers between jams to keep them from being pushed to close together
@luisluigigarcia46303 жыл бұрын
Lol
@BlackWolf-ud2zx Жыл бұрын
Thank you.
@jbb88923 жыл бұрын
Very neat!
@165Dash4 жыл бұрын
My understanding from reviewing SDI literature is that the mortar...often incorrectly labelled on drawings as "grout"...is there primarily for sound deadening purposes, NOT anchorage integrity or fire resistance. In most contemporary buildings, interior partitions that include CMU that are located in "finished" areas usually include furred out gypsum wallboard and are thus "hybrid" in character. In those cases is it safe to assume that mortaring-in of the frame should not be done and that another type of anchor should be used? My understanding is that SDI is against the use of "grout" in any type of installation where the mortar or grout cavity communicates with any other partition cavity with gypsum wallboard materials.
@SteelDoorInstitute4 жыл бұрын
Grout is usually troweled into frames while the wall is being built around the frame. For CMU walls, the T anchor or wire anchor between the blocks is what secures the frame when the grout or mortar dries. Frames are not required to be grouted to be fire rated. Sound deadening can be increased with the filling of a frame but other products can also accomplish this. Gypsum walls should never be grouted. Contractors pump the grout into a frame, which we specifically prohibit in standard ANSI/SDI A250.8, because it is too loose or wet and the moisture will propagate to the gypsum wall like a sponge attracts water. So you are correct that SDI is against grout being used in drywall/gypsum construction.
@jchristopher43106 ай бұрын
@@SteelDoorInstitute your white paper "the Risk of Grouting Steel Frames" also says grouting is usually not necessary for masonry construction. However if done properly it will not cause any issues w/ the frame. A thin slurry is often used & that excess water often causes rust.
@rc846 Жыл бұрын
Put the hardware side of the frame flush to the wall face. Not centered in the block. So door can open to 180 degrees to the wall.
@DanTheManIOM5 жыл бұрын
What if the wall is build and the original door frame was wood ?Do they make "replacement" frames that are not new construction ?
@raymondjaundoo59236 жыл бұрын
Great job guy's
@zohebimran75938 жыл бұрын
Thanks for the information, its very useful..!
@ainasyafiqah2896 Жыл бұрын
If the contractor finish the mason block first, how to install the bracket that set on the floor??
@yudhveerrana48716 жыл бұрын
Very nice
@luns486 Жыл бұрын
Anyone know how to remove one of these frames from an old house?
@khabuda Жыл бұрын
Out of curiosity, why would you want to remove the most durable door frame that money can buy?
@luns486 Жыл бұрын
@@khabuda because mine is surrounding a large wardrobe, with large crossbeams across it for holding the doors and a shelf, and I want to modify the wardrobe. As great as these are, they present large and difficult problems for even basic modifications.
@SurinderSingh-mu2oj7 жыл бұрын
good work
@animals42life85 жыл бұрын
What's the purpose of anchor?
@strongholds124 жыл бұрын
Juan Dela Cruz I won't even justify myself with a response to that
@machario705 жыл бұрын
Where can I get these door frames at??
@SteelDoorInstitute5 жыл бұрын
These are hollow metal frames and can be purchased from most door distributors.
@melmccoy72205 жыл бұрын
yea great job
@jt99675 жыл бұрын
👍🏼
@alexesco15212 жыл бұрын
Don’t remove the bar till the end before installing the saddle
@ibsprecastparapet27733 жыл бұрын
You keep saying check the installation for plum. You never did a video on how to correct it if the door moves away from plum.
@heroknaderi6 жыл бұрын
im building a workshop in my yard thanks for advuse
@oscarhuerta87566 жыл бұрын
Those shipping bars are always left on when ever we're doing masonry work and sometime we have to take them off ourselves.
@SteelDoorInstitute6 жыл бұрын
Unfortunately, that's not uncommon. They should always be removed prior to installation so a spreader can be used to help ensure plumb, level, and square.
@FrustratedBaboon8 ай бұрын
I also put my level up to the screen to make sure it was level, plum, and square, head neck and chest !!!! ☠
@天才的坏蛋 Жыл бұрын
这种安装方式,太老旧了!
@andrewbeck631210 ай бұрын
Umm I don't think I've ever seen a mason install door frames