Pad Foundation Design Part 1.

  Рет қаралды 44,685

Structural Engineer Calcs

Structural Engineer Calcs

Күн бұрын

Пікірлер: 26
@tarond57
@tarond57 Жыл бұрын
I'd love this type of content for CSA code, really great video !!
@JoeTengdui-nj6gm
@JoeTengdui-nj6gm Жыл бұрын
Thank you sir. So helpful in my work as a beginner in foundation design
@emmadavies7434
@emmadavies7434 3 жыл бұрын
Great video again guys! Keep them coming! Every video im learning something new :)
@TuryasinguraKenneth-in2pe
@TuryasinguraKenneth-in2pe Жыл бұрын
Can I know much about how the 6 gets in on getting the depth of the foundation please
@JoeTengdui-nj6gm
@JoeTengdui-nj6gm Жыл бұрын
I am having the same question
@jamal19581
@jamal19581 Жыл бұрын
Very useful to Civil Engineer , Thank You
@constructiongabay4609
@constructiongabay4609 Жыл бұрын
You forgot to include the assumed weight of concrete pad to be included in the Pu. The explanation is very clear btw.
@yousefkhleel6394
@yousefkhleel6394 3 жыл бұрын
Plz continue ❤️
@pinoyce
@pinoyce 2 жыл бұрын
Nice presentation.
@TuryasinguraKenneth-in2pe
@TuryasinguraKenneth-in2pe Жыл бұрын
This is so useful .... Thank you
@abbassafari4824
@abbassafari4824 3 жыл бұрын
Would you make a video about shallow foundation for walls? Thanks
@nanw.8131
@nanw.8131 3 жыл бұрын
really useful! would you make more tutorials about concrete structures, please? thank you!
@richmondprempeh4340
@richmondprempeh4340 2 жыл бұрын
What BS code states the limits for the depth?
@mashambashonhai4901
@mashambashonhai4901 2 жыл бұрын
Marvelous videos. What is the name of the fonts you are using in this specific video?
@RC-jx9nw
@RC-jx9nw 3 жыл бұрын
sir should the loads not be factored before determining required plan area foundation which would give a higher value than 2650mm width? The allowable bearing pressure is exceeded once the loads are factored. thanks.
@telestruct
@telestruct 2 жыл бұрын
the used soil permisible strength (bp=100kn/m^2) is already factored from the ultimate soil strength b-ult.
@snehalmohite341
@snehalmohite341 3 жыл бұрын
Thank you
@cypchard
@cypchard 3 жыл бұрын
Was there a reason for using SLS loading to determine the area of the footing and not ULS? Also wouldn't you reduce the bearing capacity of the soil to allow of a safety factor for variability of the soil strength?
@telestruct
@telestruct 2 жыл бұрын
For geotechnical design of foundation ared unfactored loads with ALLOWABLE soil bearing capacityto be used. For structural design of foundation, soil pressure from factored loads will be used to determine adequate depth and rebars area.
@khaledsalah3948
@khaledsalah3948 2 жыл бұрын
Please make a video to explain how to calculate depth of anchor bolt in concrete base, thanks👍👍👍
@orchardheadstudio1023
@orchardheadstudio1023 Жыл бұрын
Thanks for this content. Would these calculations work for a much smaller pad foundation, for example, a pad foundation supporting a suspended timber frame for something like a garden room? Would the principles remain similar even though the pad might only be say 200 x 200 maybe 600 deep?
@StructuralEngineerCalcs
@StructuralEngineerCalcs Жыл бұрын
Thank you for your comment and question! The principles discussed in the video can certainly be applied to smaller pad foundations, such as those supporting a suspended timber frame for a garden room. While the specific dimensions may vary, the fundamental concepts remain the same. When designing a smaller pad foundation, you would follow a similar process of determining the total loads, calculating the required area based on permissible bearing pressure, and finding suitable dimensions for the pad foundation. The principles of moment equilibrium and reinforcement design can also be applied, considering the specific loads and dimensions of the smaller foundation. It's important to note that the calculations may differ based on the specific requirements, material properties, and design codes applicable to your situation. Therefore, it is recommended to consult with a qualified structural engineer or use appropriate design resources to ensure the foundation is designed correctly for your specific application. We hope this helps! If you have any further questions or need additional information, please let us know.
@orchardheadstudio1023
@orchardheadstudio1023 Жыл бұрын
@@StructuralEngineerCalcs thank you very much for the detailed reply. Really great channel
@KatherineG-u7i
@KatherineG-u7i Жыл бұрын
the units are incorrect? 700kN/100KN/m^2 = 7 ? /m^2
@raguelbalcha3497
@raguelbalcha3497 7 ай бұрын
thankyou
@nanadansoapau6956
@nanadansoapau6956 2 жыл бұрын
thank you
How to determine the pile capacity.
5:42
Structural Engineer Calcs
Рет қаралды 61 М.
Pad Foundation Design | Punching shear check Part 2.
10:53
Structural Engineer Calcs
Рет қаралды 22 М.
Vampire SUCKS Human Energy 🧛🏻‍♂️🪫 (ft. @StevenHe )
0:34
Alan Chikin Chow
Рет қаралды 138 МЛН
Pad Footing Design - Part 1
13:42
BEng The Brazilian Engineer in Australia
Рет қаралды 17 М.
Eccentric Footing : All you Need to know
10:03
Civil Engineer Tonmoy Maity
Рет қаралды 28 М.
Foundation Design Example with Offset Column and Eccentric Moments
7:15
Footings | Why are they used?
5:57
Sabin Civil Engineering
Рет қаралды 5 МЛН
Foundation Design For Beginners Part 1
12:57
Kestävä
Рет қаралды 10 М.
How to Design Pad Footings under Eccentric Loading (N and M)? Design of reinforced concrete footings
22:12
The Efficient Civil Engineer (by Dr. S. El-Gamal)
Рет қаралды 42 М.
How to calculate the bolt diameter required to resist uplift forces.
3:02
Structural Engineer Calcs
Рет қаралды 143 М.