Structure resonance can cause radiated emission/immunity issues - how to locate a resonant structure

  Рет қаралды 2,996

Mach One Design EMC

Mach One Design EMC

Күн бұрын

Пікірлер: 14
@artiomoable
@artiomoable Жыл бұрын
Thanks for the demonstration. What solutions an fix "trouble" structure at required frequency? Thank you!
@Schauche
@Schauche Жыл бұрын
like your artical and video! very helpful. thank u so much!
@MachOneDesignEMC
@MachOneDesignEMC Жыл бұрын
Hi Yanjie, many thanks for the great support, it means a lot. All the very best. Min
@Schauche
@Schauche Жыл бұрын
@@MachOneDesignEMC I wish u a happy new year!🎆
@MJ-vt1kp
@MJ-vt1kp 2 жыл бұрын
Great video, did use also couplers for CM or DM current separation? Could you propose any
@MachOneDesignEMC
@MachOneDesignEMC Жыл бұрын
Hi there are methods of doing that, check kzbin.info/www/bejne/ZqamiaZsZZeSbK8
@KeithRisebroughUK
@KeithRisebroughUK 2 жыл бұрын
Great Video. Thanks for posting. Would you be able to advise the part number of the Directional Coupler from mini circuits ?
@MachOneDesignEMC
@MachOneDesignEMC 2 жыл бұрын
Hi Keith, sure. Most people use ZFDC-20-5+, but I used ZFDC-10-5+ in the experiment.
@hwansupark8955
@hwansupark8955 Жыл бұрын
Could this technique be effective in troubleshooting emissions within the 5 GHz WiFi frequency range, for example, above 5 GHz?
@chris_lynch
@chris_lynch 2 жыл бұрын
Thanks for the video, I'll order one of the ZFDC directional couplers to experiment with. One question though, I thought most bank cards NFC/RFID operate at 13.56MHz?
@MachOneDesignEMC
@MachOneDesignEMC 2 жыл бұрын
i am not sure. will need to check. you might be right!
@Dev_Nishabd
@Dev_Nishabd 2 жыл бұрын
Sir what is the software u r using. Did it was connected with any hardware?
@MachOneDesignEMC
@MachOneDesignEMC 2 жыл бұрын
Hi, that software controls the signal generator I used, which is from Windfreak Technologies. Hope it helps
@servetayok2058
@servetayok2058 2 жыл бұрын
May the reason for low resonance at 250MHz be due to the inefficiency of loop antennas at 250 MHZ?
Locating Power Supply Unit Noise Source - Using a magnetic field loop
7:01
Mach One Design EMC
Рет қаралды 2,1 М.
Engineers' Guide to Pre-compliance Radiated Emission Test
55:32
Mach One Design EMC
Рет қаралды 9 М.
World’s strongest WOMAN vs regular GIRLS
00:56
A4
Рет қаралды 45 МЛН
Haunted House 😰😨 LeoNata family #shorts
00:37
LeoNata Family
Рет қаралды 15 МЛН
PRANK😂 rate Mark’s kick 1-10 🤕
00:14
Diana Belitskay
Рет қаралды 12 МЛН
The Singing Challenge #joker #Harriet Quinn
00:35
佐助与鸣人
Рет қаралды 39 МЛН
Demystifying Conducted Immunity Tests - Pitfalls, Calibration & Testing
29:35
How to Pass Radiated EMC. 3 Mistakes to Avoid
13:16
Dr. EMC
Рет қаралды 6 М.
Demystifying EMC : Structural Resonance (The Primary Cause of EMI Issues)
11:31
EEVblog #548 - EMC Pre-Compliance Conducted Emissions Testing
27:39
An Engineer's Guide to Pre-compliance Radiated Emission Test - Short Version
23:45
How do Digital and Analog Clocks Work?
15:36
Branch Education
Рет қаралды 456 М.
Demystifying the "Hump" in conducted emission - Resonance Explained
11:01
Mach One Design EMC
Рет қаралды 1,1 М.
World’s strongest WOMAN vs regular GIRLS
00:56
A4
Рет қаралды 45 МЛН