Sump pump install in a combo radon pit. #home #basment #plumbing #water #sumppump #dehartplumbing #work #letsgetit
Пікірлер: 31
@chasehawk15362 ай бұрын
It'll all looks good!!! I'd put a union instead of a coupling at the end to make maintenance easier but everyone's different
@BluexSteel9 ай бұрын
I'm surprised you didn't put in a new check valve during your install. When the check valve goes bad it could cause the pump to fail.
@ronthemogul5 ай бұрын
I like that coupling setup. What’s that adapter size?
@davidnguyen5972Ай бұрын
why did he drill a hole in the pipe? what is the purpose of that, may i ask?
@ardabeats202527 күн бұрын
Weeping hole helps to relieve air in the pipe
@tremsmom8274 Жыл бұрын
If the diameter of the hole itself us 16”, can I use an 18”cover to seal it? Or does it have to be a smaller size? Thanks
@officialgru420 Жыл бұрын
Yup
@peterstangierski92064 ай бұрын
So fast..Tornado
@colombianvioletsАй бұрын
Thats a radon reduction system…
@WilliamDye-willdye Жыл бұрын
Is that a GFCI receptacle? My new pump manual says it's required.
@cbausch70256 ай бұрын
That’s not a good idea . It’ll always trip
@patty1091092 ай бұрын
@@cbausch7025not so. Apparently code mandated it for my home. In any case, four years now dehumidifier going against that outlet and a sump and it doesn’t trip
@FF60MpD9 ай бұрын
Why 2 cables? Why 2 cables before too?
@Jessedog115 ай бұрын
float switch
@lindsaymartin1933 Жыл бұрын
Waht is this
@DaDaDo6619 ай бұрын
Sump pump
@stevevaladez09 Жыл бұрын
What's that other pipe for? For radon vent?
@TjStammen10 ай бұрын
Yes
@patty1091092 ай бұрын
I think that’s also why the sump crock is sealed. Many homes like mine don’t have it sealed.
@FF60MpD9 ай бұрын
Why 2 pipes?
@jcpoiuy6 ай бұрын
Larger 3” piping is for Radon venting.
@shariqkudcs Жыл бұрын
The anti air lock hole is on wrong height on sump pump discharge
@vonmajor6 ай бұрын
How high is it supposed to be? My pump is cycling rapidly and I see water shooting out that vent hole when it runs. Not sure if pump is failing but runs 3 to 5 x’s long than it used to do.
@byronrobinson86334 ай бұрын
@@vonmajorI don’t think it’s supposed to be to high. I don’t think it matters if it’s low as long as above pump. You want it low enough because water is supposed to shoot out and you want the hole where it shoots back in pit. So it definitely needs to be in the pit area at least and make sure you angle the hole where it’s shooting downwards if you drill a new hole in pipe.
@bfullsyou2 ай бұрын
Air rises in water, so higher is good, but low enough so it sprays into pit.
@kathypariso6102Ай бұрын
I guess this was some kind of race? As an instructional video, it was pretty useless.
@BeeBombard Жыл бұрын
Forgot your shutoff
@jdewitt-pn9kr Жыл бұрын
Lol what
@TheCHOCOLATEsteven Жыл бұрын
He should’ve put a union where that coupling was installed. I was taught to put a union, check, and ball valve so that shit doesn’t rain down on you if you need to disconnect the discharge while it’s full. The swing check valve alone would make me nervous