Tech Tips: How to Resolve a 5 Time Flash (L)

  Рет қаралды 54,090

Mitsubishi Electric Trane US

Mitsubishi Electric Trane US

Күн бұрын

Пікірлер: 14
@Raaa1111..
@Raaa1111.. 2 жыл бұрын
Is it possible for the whole system to shut down do to overheating if the outside temp goes over 85 degrees? And the system running add on to that temp around it?
@dinhdnguyen
@dinhdnguyen 14 күн бұрын
Not very clear on how to diagnose the compressor.
@HJiAZI
@HJiAZI 2 ай бұрын
Mine happens after running for around 5-6hrs. Anyone has experience with similar duration before the 5 flashes happens?
@medawurm
@medawurm Ай бұрын
sometimes it runs for a week with no issues. or it runs for a few hours and faults with 5 blink overcurrent. chkd the recall function with remote and its an overcurrent.
@Hayden24789
@Hayden24789 4 ай бұрын
And after You get the 5x flash black diamonds industries( mitsubishi electric) won't wana know ya and recommend you buy a whole new unit even though your $6000 unit was installed 5.5 years ago ( Just out of warrenty)
@bracingair8208
@bracingair8208 5 жыл бұрын
Sir. Can I ask. This apply for inverter only ya? Assuming you mention "our compressor is a slow torque".
@randynBroncos
@randynBroncos 2 жыл бұрын
Hi, if this is a board issue, is it the outdoor PCB, or could it be the indoor PCB board?
@ArcheryRuleZ
@ArcheryRuleZ 8 ай бұрын
outdoor.
@lindachevelle761
@lindachevelle761 3 жыл бұрын
I have the 5 flashes, sometimes it works though both in heat and cool mode, more often than not it doesn’t work though, any extra hints on what the problem may be?
@randynBroncos
@randynBroncos 2 жыл бұрын
@Linda Chevelle, hi, did you figure out the problem? What needed to be changed? The board?
@md.nasim.ansari3188
@md.nasim.ansari3188 3 жыл бұрын
Sir mitsubishi electric inverter pcb 10 time outddor led blikig plese sir talmi
@easonwee
@easonwee 6 жыл бұрын
Thank you for the great videos. Well done!! Would you be able to show how to diagnose and change a condenser fan or the power board? 13 times red LED (1) flash with amber LED unlit. Item is fan abnormality. Possible fan motor or board failure? Thank you so much.
@babaolowo35
@babaolowo35 2 жыл бұрын
Thanks 👍
@عبدالكريممحمدايتكلداس
@عبدالكريممحمدايتكلداس Жыл бұрын
tanks
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 680 М.
Tech Tips: How to Diagnose a Shorted Power Board (L)
4:07
Mitsubishi Electric Trane US
Рет қаралды 47 М.
Какой я клей? | CLEX #shorts
0:59
CLEX
Рет қаралды 1,9 МЛН
번쩍번쩍 거리는 입
0:32
승비니 Seungbini
Рет қаралды 182 МЛН
She wanted to set me up #shorts by Tsuriki Show
0:56
Tsuriki Show
Рет қаралды 8 МЛН
Mitsubishi Mini Split Repair
20:24
T&N Services LLC.
Рет қаралды 110 М.
Technically Speaking EP1: Mitsubishi Electrical Troubleshooting
6:08
Tech Tips: Resolving a 3-Time Flash (L)
3:40
Mitsubishi Electric Trane US
Рет қаралды 30 М.
Tech Tips: Resolving Thermistor Errors (L)
3:08
Mitsubishi Electric Trane US
Рет қаралды 94 М.
Repair of cylinder head thickness.
18:41
Las 2000
Рет қаралды 240
How To Make magic pen from old spark plug
9:27
Holic Tips
Рет қаралды 86
Какой я клей? | CLEX #shorts
0:59
CLEX
Рет қаралды 1,9 МЛН