Technically Speaking EP1: Mitsubishi Electrical Troubleshooting

  Рет қаралды 106,537

Meier Supply

Meier Supply

Күн бұрын

Пікірлер: 38
@wilsongb09
@wilsongb09 5 жыл бұрын
Very good video on troubleshooting. Very helpful.
@argenismoreno8838
@argenismoreno8838 4 жыл бұрын
Thanks for this video, I haven't worked with this kind of A/C but it's good to learn something new and so important . From Venezuela. 🇻🇪👏🙋‍♂️
@andreagate542
@andreagate542 3 жыл бұрын
Great video and thank you very much, I typically work on the water source heat pump’s and I do have experience installing Dr. splits but I’ve never had to service one,,, this video has given me a great first step in troubleshooting☝️🙏🏾🙏🏾🙏🏾🍺
@stephenking7660
@stephenking7660 Жыл бұрын
Good video. Very helpful
@thomasdaddy7156
@thomasdaddy7156 7 ай бұрын
That was a great training video great job
@stlbrian33
@stlbrian33 4 жыл бұрын
Thank you, very helpful.
@katelynnselman409
@katelynnselman409 2 жыл бұрын
thank you for this video it made me call a repair tech within 4 minutes of watching because i realized i have no chance of doing this with my cute little pink tool set from home depot lol
@braidysjburgos6504
@braidysjburgos6504 4 жыл бұрын
Great video, very informative.
@mariobryant8803
@mariobryant8803 4 жыл бұрын
Very thorough
@desireemillion
@desireemillion 3 жыл бұрын
wires crossed where? Are you going to do a video where you fix the issue?
@OthmanAlikhan
@OthmanAlikhan 3 жыл бұрын
Thanks for the video =)
@royallan3717
@royallan3717 2 жыл бұрын
Fujitsu use a diode on black lead to show a steady voltage on 3 or signal wire
@eddiegomez3628
@eddiegomez3628 2 жыл бұрын
is this training from trane mitsubishi hvac classes on their website?
@Basssmaster
@Basssmaster 2 жыл бұрын
If you lose one leg coming into the unit would that cause damage to the unit or do they protect themself?
@royallan3717
@royallan3717 2 жыл бұрын
Why not remove signal wire at outdoor unit and measure out there
@peterndwiga4694
@peterndwiga4694 5 ай бұрын
How about Mitsubishi split unit blinking 14 times?
@jimmylee1856
@jimmylee1856 3 жыл бұрын
Hello I would like some one tell me where I can get mini slips troubleshooting please
@RP-mt6bp
@RP-mt6bp 3 жыл бұрын
Thank you, again. I have watched it the second time. Zone 1, OU (outdoor unit) has identified a problem with the indoor PCB. The OU is giving a steady voltage between S2 and S3 and should fluctuate on DCV. This means that the indoor PCB needs replaced. On Zone 2, S2 to S3 is fluctuating in AC at low voltage. We should have a steady 210V. DC should be fluctuating between 12 and 26V at S2 to S3 but it is fluctuating at AC high voltage instead. That is an indicative that a short or a cross in the wiring. Is the PCB of OU faulty, as well?
@boklc1537
@boklc1537 4 жыл бұрын
HI How to check for inverter compressor voltage? What is the minimum voltage for the compressor to opreate
@Andrew-zc9le
@Andrew-zc9le Жыл бұрын
Where is the video that tells you what it means if both indoor and outdoor units have non fluctuating DC current between s2 s3
@andyreyes6464
@andyreyes6464 9 ай бұрын
I been researching, the s3 connection has 120v ac but conducts DC voltage like power line communicating. There is two capacitors at the S3 connector where the DC signals is send from one end and stop at the other end and is collected for capacitor read the pulsation signals and passes the AC signal flowing with no interference
@craigpurdom1727
@craigpurdom1727 6 ай бұрын
Just disconnect the interconnect wires and check on outdoor is what I do
@ishika562
@ishika562 4 жыл бұрын
Hello Sir, Is it possible to add reverse valve in the inverter ac's. The ac is of R32 gas and 2.2 ton.. Mitsubishi electric GR series model
@josephpietrzak2976
@josephpietrzak2976 4 жыл бұрын
Posssible yes. Not even close to worth it. You mine as well but a new system
@RP-mt6bp
@RP-mt6bp 4 жыл бұрын
Thank you. Where can I find EP2, the continuation of this?
@MeierSupplyCo
@MeierSupplyCo 4 жыл бұрын
You're welcome! Technically Speaking is our series of videos on different topics. There isn't a second episode for this topic, however we plan to release more videos on Mitsubishi Troubleshooting soon.
@jakemilkovich1722
@jakemilkovich1722 Ай бұрын
@@MeierSupplyCo Soon? 3 years ago?
@benocloobenbenjohnson5226
@benocloobenbenjohnson5226 3 жыл бұрын
To connect without board
@donovanlapat7562
@donovanlapat7562 3 жыл бұрын
Does anyone know if this is fairly standard across brands? (Mitsubishi, Daikin, Fujitsu, etc?) In my limited experience with them (almost exclusively installation), they appear to be wired in much the same way but I have no idea in the differences of board function
@LC-qi5ff
@LC-qi5ff Жыл бұрын
This is pretty standard , although some makes like toshiba have fluctuating ac voltage between s2 & s3 and so s1 to s3 will also be fluctuating ac voltage
@craigpurdom1727
@craigpurdom1727 6 ай бұрын
Mostly
@whitewigglesworth
@whitewigglesworth 3 жыл бұрын
Anyone else notice the suction line freezing?
@mackenziegray2090
@mackenziegray2090 2 жыл бұрын
Probably from the board not communicating with the inside, so the blower wheel is not operating. Maybe reason for a freezing up line.
@craigpurdom1727
@craigpurdom1727 6 ай бұрын
@@mackenziegray2090yes that’s the answer
@baptistelauzier
@baptistelauzier 3 жыл бұрын
What if I have power coming to the outdoor circuit board but none leaving to the indoor units?
@johnnymckillen2223
@johnnymckillen2223 3 жыл бұрын
More than likely it'll be a fuse has blown
@sarathlallal4523
@sarathlallal4523 4 жыл бұрын
Wapp nu plzzz sir
@harryschrysan3183
@harryschrysan3183 Жыл бұрын
Is that reading method the same for all inverter mini splits?
Mitsubishi ductless mini split heat pump not heating
24:30
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 37 М.
#behindthescenes @CrissaJackson
0:11
Happy Kelli
Рет қаралды 27 МЛН
Wednesday VS Enid: Who is The Best Mommy? #shorts
0:14
Troom Oki Toki
Рет қаралды 50 МЛН
OCCUPIED #shortssprintbrasil
0:37
Natan por Aí
Рет қаралды 131 МЛН
Electrical Troubleshooting Basics
5:22
RSP Supply
Рет қаралды 161 М.
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59
Quality HVACR
Рет қаралды 856 М.
Nobody Will Tell u like this Electrical Troubleshooting @TheElectricalGuy
10:34
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 683 М.
Mitsubishi Ductless Split Shut Off on OverCurrent Faults
24:25
The HVAC Hacker
Рет қаралды 44 М.
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,2 МЛН
CAN Bus Properties and Troubleshooting
18:09
Enovation Controls
Рет қаралды 1,4 МЛН
How to Work on Mini Splits?
30:30
Taddy Digest
Рет қаралды 131 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 2,2 МЛН