No video

OLTC: On Load Tap Changer. A complete and Practical explanation

  Рет қаралды 41,895

Electro Globe

Electro Globe

Күн бұрын

Пікірлер: 34
@mrida3017
@mrida3017 2 жыл бұрын
Thanks for the video, I want to correct one thing: 1:25 these are tie-in resistors which are used to limit the recovery voltage during the operation of change-over selector. Change-over selector is equipped to OLTC when we need higher operating positions with a limited tap selector contact quantity. For example: OLTC with 10 selector contacts and without change-over selector: can operate up to 10 positions only, while the same OLTC when equipped with change-over selector can operate up to 19 positions (10*2 -1). The transition resistors used to limit the circulating current duration tap switching are located inside the diverter switch insert in the oil compartment of OLTC.
@ElectroGlobe1
@ElectroGlobe1 2 жыл бұрын
Thank you for the comment
@shengjitee2539
@shengjitee2539 4 жыл бұрын
Thanks a lot for the educational video!
@ElectroGlobe1
@ElectroGlobe1 4 жыл бұрын
Welcome. Glad it was helpful!
@surajchakraverty624
@surajchakraverty624 4 жыл бұрын
Thank you for the enlightenment sir. Wonderful sharing packing with full of information.
@ElectroGlobe1
@ElectroGlobe1 4 жыл бұрын
Welcome
@rameshtripathy5978
@rameshtripathy5978 3 жыл бұрын
Excellent description & helpful too !
@ElectroGlobe1
@ElectroGlobe1 3 жыл бұрын
Thank you
@runbou3485
@runbou3485 Жыл бұрын
Thankអរគុណ👏
@markangelomuan6855
@markangelomuan6855 3 жыл бұрын
Good presentation. Thanks
@ElectroGlobe1
@ElectroGlobe1 3 жыл бұрын
Welcome
@runbou3019
@runbou3019 2 жыл бұрын
អគុណបង
@ElectroGlobe1
@ElectroGlobe1 2 жыл бұрын
សូមស្វាគមន៍ (Welcome)
@ashishmahajan7223
@ashishmahajan7223 4 жыл бұрын
Hi sir,i have the following questions: 1. How does the OLTC work automatically as in how does it measure the change in load and changes it taps accordingly? 2. As shown,there is also a counter inside and while doing the O&M, we check how many times OLTC operated.I wanted to know is there a certain value in the counter above which we can tell that it can cause problem to the OLTC? 3. The motor used is AC or DC?
@ElectroGlobe1
@ElectroGlobe1 4 жыл бұрын
Thank you for your comment. Following are the answers to your questions. 1. There can be two ways to monitor voltage change, if one observes voltage change beyond limit, OLTC is operated. Also there are OLTCs with AVR system called as automatic voltage regulation. In this case voltage is monitored and regulated automatically. That means OLTC changes tap automatically. 2. Yes. After certain number of operations, it is advised to do OLTC servicing in consultation with respective manufacturers. Also life of OLTC is related to number of OLTC operations. 3. The motor used is AC motor.
@wilbertabrea354
@wilbertabrea354 4 жыл бұрын
Nice!! May i ask about off load tap changers? Are they connected on high voltage side too? Thanks.
@ElectroGlobe1
@ElectroGlobe1 4 жыл бұрын
Thank you. Yes octc is connected on HV side.
@vishalkarthik.v7209
@vishalkarthik.v7209 3 жыл бұрын
Sir ,so the concept is put the HV winding inside LV winding ...
@ElectroGlobe1
@ElectroGlobe1 3 жыл бұрын
Yes
@lalitgalani575
@lalitgalani575 3 жыл бұрын
sir, is there any video for dissolved gas analysis of transformer oil
@ElectroGlobe1
@ElectroGlobe1 3 жыл бұрын
Video about DGA will be as soon as possible.
@himanshu2232
@himanshu2232 4 жыл бұрын
Sir please make vedio on capacitor bank in substations
@ElectroGlobe1
@ElectroGlobe1 4 жыл бұрын
Sure. Video on capacitor bank will be uploaded soon.
@himanshu2232
@himanshu2232 4 жыл бұрын
@@ElectroGlobe1 sir I will always wait for your new vedio .
@himanshu2232
@himanshu2232 4 жыл бұрын
@@ElectroGlobe1 please upload more vedio,your vedio is more informative for us.
@ElectroGlobe1
@ElectroGlobe1 4 жыл бұрын
@@himanshu2232 thank you
@wilbertabrea354
@wilbertabrea354 4 жыл бұрын
Sir, do you have video regarding oil degasifiers? Thanks
@ElectroGlobe1
@ElectroGlobe1 3 жыл бұрын
Please check the video about silica gel Breather kzbin.info/www/bejne/nqGQqnSuh8mCfq8
@enamulhaque630
@enamulhaque630 4 жыл бұрын
What is current rating of tap changer
@ElectroGlobe1
@ElectroGlobe1 4 жыл бұрын
Current rating varies for different OLTCs. Standards for OLTC has details about current rating. Hope this answers your query.
@enamulhaque630
@enamulhaque630 4 жыл бұрын
@@ElectroGlobe1 Actually my question was how current rating of OLTC relates to Transformer rating. Or no relationship
@ElectroGlobe1
@ElectroGlobe1 4 жыл бұрын
@@enamulhaque630 yes. OLTC and Transformer ratings are related.
@zachsieg2332
@zachsieg2332 Жыл бұрын
The narration of this video makes this completely unwatchable
@ElectroGlobe1
@ElectroGlobe1 Жыл бұрын
Thank you for the feedback
Transformer On Load Tap Changer Installation تركيب مغيرات الجهد فى المحولات
11:33
EEEB Electrical Engineers Experience Building
Рет қаралды 15 М.
Primary Voltage Taps on a Transformer
7:13
Zack Hartle
Рет қаралды 27 М.
WHO CAN RUN FASTER?
00:23
Zhong
Рет қаралды 45 МЛН
SPILLED CHOCKY MILK PRANK ON BROTHER 😂 #shorts
00:12
Savage Vlogs
Рет қаралды 49 МЛН
On Load Tap Changer :- How it works?
9:10
sourabh sharma
Рет қаралды 173 М.
ABB UZ Tap Changer and Motor Drive Unit Operation and Maintenance part 1
20:27
EEEB Electrical Engineers Experience Building
Рет қаралды 18 М.
Response to: Watch electricity hit a fork in the road at half a billion frames per second.mp4
11:14
Transformer Current and Power
18:55
Dave Gordon
Рет қаралды 14 М.
MR VACUTAP® VM®
3:15
ReinhausenTV
Рет қаралды 71 М.
DIVERTER SWITCH AND SELECTOR SWITCH OF OLTC1
8:42
EDDY CURRENT
Рет қаралды 7 М.
The Big Misconception About Electricity
14:48
Veritasium
Рет қаралды 22 МЛН
Graphite bomb
4:52
Operational Facts
Рет қаралды 14 М.