Tektronix 475A Alignment Part 1 (Power supply and Tube)

  Рет қаралды 1,538

Zenwizard Studios

Zenwizard Studios

Күн бұрын

Пікірлер: 9
@CraigPetersen12f36b
@CraigPetersen12f36b Жыл бұрын
I just purchased a 475A with the DM 44 option. ($25.00) More or less had to use control cleaner to bring it back to life and as far as I can tell that was the only thing wrong with it. It appears to have been serviced in the last 15-20 years because it's still very close to "spec". However I still need to check the power supply for ripple etc.. Very useful tips in the video, thanks.
@ZenwizardStudios
@ZenwizardStudios Жыл бұрын
Thanks!, glad the videos helped. On ALL 475 units there are 15 transistors that will require replacement most on the trigger board some on the main board. More info on the fault can be found here - kzbin.info/www/bejne/nXa7ioWGg9Sbr6M Zen
@jimbert50
@jimbert50 2 жыл бұрын
I would like to see a calibration video for a 2465, especially the horizontal sweep cals.
@ZenwizardStudios
@ZenwizardStudios 2 жыл бұрын
I do plan on making a video on this one but I need a 2465 for the lab to put in front of the lens.
@jimbert50
@jimbert50 2 жыл бұрын
@@ZenwizardStudios I would be happy to lend you mine, but shipping would be a pain. I'm in USA; not how far away you are. I calibrated mine and it seems good, but I'm new to this and don't have the best calibration equipment for it and what I have is not Tektronix. I made do with a Juntek PSG9080 waveform generator and a cheap square wave generator for the higher frequencies. My DMM was more than adequate though.
@davesdigitaldomain
@davesdigitaldomain 2 жыл бұрын
when doing the geometry adjustments, is it possible to use a square wave from a signal generator instead of using a time mark generator? I have a signal generator with the rise and fall time of 4 ns would that be adequate?
@ZenwizardStudios
@ZenwizardStudios 2 жыл бұрын
It might be the critical parameter is a straight line. So any straight line should work.
@hkhjg1734
@hkhjg1734 2 жыл бұрын
I have a 2445 scope where the text is slightly offset from where it should be (top text little higher and bottom text a little lower). Does anyone know if this is something that calibration fixes or is this indicative of a bigger issue?
@ZenwizardStudios
@ZenwizardStudios 2 жыл бұрын
I will check the service manual but I think there are position controls adjusted during the alignment process at least there are on the 7000 series. Is the wave form compressed or expanded i would expect a slight expansion. at all when looking at a squairwave? This might indicate a vertical center issue as well the amp and the tube are miss aligned but if it is only off slightly I would expect alignment/adjustment not a major issue with the vert amp
Tech Argues with Scope-Scope Wins-For Now (More Troubleshooting to follow)
26:20
Tektronix 475A and DM44 Repair Power Supply and Logic
28:29
Zenwizard Studios
Рет қаралды 3,6 М.
Бенчик, пора купаться! 🛁 #бенчик #арти #симбочка
00:34
Симбочка Пимпочка
Рет қаралды 3,1 МЛН
How it feels when u walk through first class
00:52
Adam W
Рет қаралды 21 МЛН
Миллионер | 1 - серия
34:31
Million Show
Рет қаралды 2,9 МЛН
😜 #aminkavitaminka #aminokka #аминкавитаминка
00:14
Аминка Витаминка
Рет қаралды 1,2 МЛН
HP 201CR Restoration and Repair
26:54
Zenwizard Studios
Рет қаралды 82
Tektronix 585A Restoration and Troubleshooting (Part 1)
33:14
Zenwizard Studios
Рет қаралды 2,5 М.
Flawless PCB design: RF rules of thumb - Part 1
15:45
Hans Rosenberg
Рет қаралды 78 М.
MP3 CDs: a hybrid "format" that never existed, yet was surprisingly common
34:18
Technology Connections
Рет қаралды 678 М.
Pioneer Laser Disc Player
30:10
Mend It Mark
Рет қаралды 124 М.
#772 Basics: Switching Power Supplies (part 1 of 2)
26:17
IMSAI Guy
Рет қаралды 439 М.
Intro to Tektronix 465 Oscilloscope
12:59
Retro Logic Lab
Рет қаралды 41 М.
Tektronix 555 Troubleshooting to unobtainum
21:12
Zenwizard Studios
Рет қаралды 1,6 М.
Бенчик, пора купаться! 🛁 #бенчик #арти #симбочка
00:34
Симбочка Пимпочка
Рет қаралды 3,1 МЛН