You can tell the electrician is a master of his craft. His cable management and use of tools is like a work of art.
@kurtalexander3683 Жыл бұрын
Indeed, I was an electrician in the Army, that brought back memories
@t1m3l0rd Жыл бұрын
Except he landed the breaker first which is wrong and specially bad that it’s in a video.
@rocketman1969 Жыл бұрын
Exactly
@MrAncientAstronaut7 ай бұрын
He didn't torque the termination screws in the breaker
@quintontate9035 ай бұрын
Yea, and also he used (2) red phase instead of black & red, but there is always gonna be critics, especially if this is your field of work (profession) but his work was correct and clean! He gets an 8.5/ 9 out of 10! Good job guy!
@adamn.95256 ай бұрын
So grateful for someone doing a video with a licensed electrician so we don't have to look in the comments for what the installer did wrong. Thanks
@tesbros6 ай бұрын
Glad it helped
@electricianron_New_Jersey Жыл бұрын
#6 copper THWN is sufficient for 60 amps and a #10 AWG copper equipment grounding conductor is an industry standard ground for a 60-amp load. That open KO seal should also be closed up.
@rudeman1914 Жыл бұрын
You made it look easy pulling that #6 wires in 3/4
@janetyeoman1544 Жыл бұрын
Long runs are easier with staggered wire ends taped and tied. Lube helps. His short run was simple.
@thelemonlimeninja21446 ай бұрын
Short run, 180 degrees of bend, and super slicks. Easy of a pull as you’re likely to find.
@euphoricmonk5 ай бұрын
That looked like 1/2 conduit
@TheLawIX2 ай бұрын
@@euphoricmonk You'd need 1" minimum to meet code.
@brynnrogers50813 ай бұрын
at 9:20 or so, you should not use an impact driver for screws (that are probably going into plastic), really easy to strip. use a drill with the torque set down to like '10' out of 20 (20=drill) if you need power driver, hand screwdriver works well too, and much easier to not over torque. Code here in Minnesota is now requiring GFI breakers even for 240 v circuits like my welder and soon to be installed Tesla wall charger.
@jeemse39834 ай бұрын
Quick clean install, but going to echo another comment about torquing the terminal screws in the wire box and breaker. They need to be torqued to 50 lbf . in (pound-force inch) as per manual. Loose wires at terminals will create arc, arcs create electrical fire. Stay safe out there!
@jackvang872 жыл бұрын
This vid was immensely helpful for insight on how to remove one as well. Moving and locals are charging a grip just to take it off the wall.
@tesbros2 жыл бұрын
So glad it helped, Jack!
@jaxxone4907 Жыл бұрын
best video ever. i was able to install mine by myself.
@iv2917 Жыл бұрын
What gauge wire does this use, for a 60 amp breaker? Also, what is the length of the charging cable? (To the car) Thank you.
@stevewoodyt6 ай бұрын
@@iv29176. It’s in the manual. Minimum 6 awg. The directions are for a 60 amp hook up. I believe 6 awg 90c is rated for 75. Everything is going to need to function at 80% of rated. I’m not an electrician and this comment is purely for entertainment.
@wirenut906210 ай бұрын
Just a heads up.. if inspected, you need an expansion coupling and appropriate clips. Thanks
@rashadmarsh435710 ай бұрын
Yep, I’m an electrician and I never land the line side first, ever. I never feel comfortable. Plus on union jobs, you can get fired for that, not practicing lock out tag out
@seankher2 жыл бұрын
Best install video. It was a great idea to have your Professional Electrician doing the work.
@RyanRamtahal-u1n11 ай бұрын
what gage wire you use?
@gapo62angler932 жыл бұрын
Why do people including this electrician lands their line side wires first , a great rule of thumb for safety is always land your load side wires first then the line side last , just in case someone accidentally turns on the breaker while you’re landing the wires to the actual wall charger. It’s just like in firearms “Always assume your gun is always loaded “ in electricity “Always assume your wires are always live.” ✌🏽
@tesbros2 жыл бұрын
I'm not an electrician so not sure but that makes sense!
@phillipfixes2 жыл бұрын
I'm fresh AF and my last land is always line side
@seanb76142 жыл бұрын
Lock out tag out kids
@Erick.castillo2 жыл бұрын
I install power walls and chargers all the time you’re 100 percent right it’s bad practice
@christianthieret80882 жыл бұрын
Your wires shouldn’t be landed on the breaker while doing this kiddos lol so it won’t matter
@rborroto2 жыл бұрын
Nice, simple installation, similar to mine. However, I'm surprised he used steel pipe straps. Hopefully they're galvanized. Check them, because they may rust. You may consider replacing them with non-metallic (grey) straps, should you run into a rust problem. Thanks for sharing.
@tesbros2 жыл бұрын
Thanks for the tips!
@WayneStratton2 жыл бұрын
lol
@RB-xv4si Жыл бұрын
They’re called straps, not clips.
@rborroto Жыл бұрын
@@RB-xv4si thanks, I've updated my comment.
@cybernoyp1 Жыл бұрын
Best Tutorial! I used this guide to install my Gen 3 DIY outdoor. The mini 15s/20s breakers was the best idea since I didn’t have space for 60A. Great job
@RB-xv4si Жыл бұрын
They’re called tandem breakers.
@reefgratos2035 Жыл бұрын
The electrician i hired did mine for $800 that included the 50 amp rated wire and the 40 amp breaker. He put a range outlet so i can plug the mobil charger. My tesla is in a garage.. so i dont need the wall charger. he also told me that he did about 400 charger installs in his life so far… not bad.. the demand is rising…. Because i only have a model 3 rwd which can only be charged at 32 amp. i don't think i would ever need a 60 amp breaker with 60 amp rated wire,,, for me 32 amp is more than enough to charge a model 3 rwd.. (actually any tesla). Maybe someday if i have extra money i would try a gen3 wall charger, if i can find one used.. but for now the mobile charger does the trick on my m3 rwd…
@Anonymous014163 ай бұрын
60/50AMP rated wire is a 6 gauge copper wire and you would use a 50AMP breaker or 60 amp breaker depending on the setup. You should ask your electrician what gauge copper wire he used on your setup.
@Gruntled20012 жыл бұрын
Need to use a torque screwdriver on both the breaker and the charger base terminals. No matter how experienced a sparky you think you are, 80% of electricians don't torque their terminals right, which is a problem down the line.
@filibertosalinas6816 Жыл бұрын
Why is it an issue?
@Gruntled2001 Жыл бұрын
@@filibertosalinas6816 1. The code says so. 2 improperly torqued connections are a big problem.
@ac777 Жыл бұрын
@@filibertosalinas6816 Incorrectly torqued terminals can cause the connection to arc and spark, starting a fire; or it can make the components work harder than they should, which leads to overall component degradation.
@RB-xv4si Жыл бұрын
If you have under torqued terminals, that leads to increased resistance and increased heat stress, which is what causes fires. So yeah, it’s important. Also it’s a code requirement; 110.14(D)
@tokentoker2392 Жыл бұрын
Is a problem but probably won’t affect the consumer… similar to putting tires on your car with a torque wrench… tight enough is usually good… “MOST” of the time
@notsure75548 ай бұрын
I installed mine with ROMEX, nails and a rusty screwdriver and it's working fine.
@Ranger42 Жыл бұрын
Curious, why no Neutral White wire in this install.
@judeghazaleh61349 ай бұрын
Yeah man, great video. I was worried about installing this at first, but I'm glad it's a lot more simple than I thought. But what I really don't understand, is why you can put a 48 amp load on a 60 amp breaker, but you can only put a 32 amp load on a 50 amp breaker. Shouldn't you be able to charge at 38 amps with a 50 amp breaker? I know if you get too close to the overload threshold current of a breaker, it overheats the element of the disconnect mechanism, and can damage it, making it impossible to turn back on once it turns off, and worst case scenario it can make enough heat to cause some polymer in the fuse box to catch fire. What I don't understand is why you can get within 12 amps of the 60 amp threshold, but you can get within only 18 amps of the threshold of a 50 amp breaker. I'm thinking the element for the diffusing mechanism in the 60 amp is a little more resistant to heat then the element in a 50 amp breaker, which actually allows you to safely get closer to the maximum load of the 60 amp breaker.
@robntrades9326Ай бұрын
Thanks for the video, everything was explained perfectly
@andrewpham8665 Жыл бұрын
Nice outdoor install Bro! Did you remove the label showing the QR code so no one can re-commission it if the decide to rip it off your wall?
@POLOAZTECA Жыл бұрын
Was that a neutral or ground? I saw he terminated it on the neutral bar!
@pinkiepie1656 Жыл бұрын
They are probably bound together in that panel, since it comes before in inside panel.
@RB-xv4si Жыл бұрын
You don’t need a ground wire the same size as the circuit conductors. That’s big time overkill. NEC table 250.122 allows #10 wire for the ground on a 60a circuit. He went 2 sizes bigger and there is 0 benefit to that. Just more expensive.
@nolanandert4258 Жыл бұрын
250.122 my dude. Non sparkys touching my work I tell you
@RB-xv4si Жыл бұрын
@@nolanandert4258 I know, right. They’re out in force on KZbin like they are the authority on this work. IMO, you want to DIY your own electric vehicle charger, fine. But don’t post videos acting like you actually know what you’re doing.
@nolanandert4258 Жыл бұрын
@@RB-xv4si should be putting their money into the game, we know what we are doing and get get it code legal. Pay your local electrician!!
@ddaniel2139 ай бұрын
It’s actually safer to make sure ground wire is same size as ungrounded conductors. Especially if home owners are doing a DIY install.
@JohnWoodell Жыл бұрын
You should include the setup, which is a bit confusing because you join the device to your WiFi network, but still configure it by power cycling and connecting to it as a WiFi hotspot.
@meh1943 Жыл бұрын
What about protection from rain? Is that wall charger completely waterproof on the top side? We plan to install ours outdoors too, so I am wondering if I should put some kind of shelter over the top of the unit?
@tesbros Жыл бұрын
The Tesla wall connector is waterproof! I don't have anything over mine and haven't had any issues.
@RB-xv4si Жыл бұрын
It’s a NEMA 3R rated enclosure so it’s meant to handle rain.
@AshwinRaoRocks Жыл бұрын
Thanks for posting this video. Came in very useful! Appreciate it.
@brainz-brainz Жыл бұрын
Brother doin it all on a hot panel
@agm6095Ай бұрын
What gauge wire did you use. Thanks for the video.
@tesbrosАй бұрын
we used a 6 gauge for a 60amp breaker
@agm6095Ай бұрын
Thank you.
@hgames888 Жыл бұрын
1:53 i know you probably want something custom but tesla does sell colored glass covers.
@nowsc3 ай бұрын
… do I have to use Wi-Fi with this? or can I ignore the Wi-Fi and just hook it up and it will work?
@tesbros3 ай бұрын
You don't have to use Wi-Fi with the Tesla Wall Connector for it to work. The Wi-Fi connection is primarily used for software updates, monitoring charging sessions, and adjusting settings via the Tesla app. If you're not concerned about those features, you can skip the Wi-Fi setup, and the Wall Connector will still function normally to charge your Tesla.
@RickShin-j1f Жыл бұрын
Does the wall connector turn off when not charging? In other words, does the device constantly draw current when not actively charging the car?
@tesbros Жыл бұрын
Barely any, you won't even really notice
@hughgodfrey99336 ай бұрын
I think it might draw 1 or 2 watts to keep the wifi active.
@IanVolkel2 ай бұрын
Can you use stranded wire or do you have to use solid
@tesbrosАй бұрын
Either stranded or solid wire can be used, but there are some considerations: - Stranded Wire is more flexible, which can make it easier to work with, especially when routing wires through tight spaces. Tesla’s installation manual specifies that if stranded wire is used, the installer should ensure that all strands are securely contained within the terminal connection to prevent issues like overheating. - Solid Wire is generally more rigid and may be more difficult to work with in terms of bending and fitting into terminals. It provides a more stable connection when properly secured. Tesla’s Wall Connector manual doesn't mandate the use of either stranded or solid wire but emphasizes proper installation, ensuring that the wire gauge meets electrical code requirements and is appropriate for the amperage of the Wall Connector. If in doubt, it's always good to follow local electrical codes and consult an electrician!
@R0B0T2k2 жыл бұрын
I ran some 6AWG through 3/4 inch it was a pain in my ass. But I had more bends, which might have been why.
@R0B0T2k2 жыл бұрын
I feel like you need 1 inch for 3+1 6AWG.
@R0B0T2k2 жыл бұрын
Ok I see, he used already separated wiring. I used 3+1 6AWG that was sleeved together already.
@jeffferraro49812 жыл бұрын
@@R0B0T2k I'm getting conflicting information from everywhere. I was getting 6/2 sleeved to run mine but some people are saying you need a neutral. I don't see anywhere, including in the Tesla manual that you need a neutral. All manuals show 2 hot, 1 ground. I'm connecting directly to my main panel with a 60A breaker.
@mostafa6852 жыл бұрын
@@jeffferraro4981 you don’t need a neutral but, that 6/2 sleeved isn’t up to code for the 60 amp breaker. You need THHN like in this video
@michaelhlavacek5159 Жыл бұрын
Then you should run # 4 wire. For 60 amp breaker.
@kyniemyeuem20244 ай бұрын
question: why you don't connect the panel inside the garage. I only have 1 electronic panel inside the garage...........
@tesbros4 ай бұрын
This is the only panel I have. If yours is in the garage, that's no problem. Use that one.
@ac_tv20502 ай бұрын
Is it ok to install 60amps charger on a 200amps house panel?
@tesbros2 ай бұрын
Yes, it is generally okay to install a 60-amp charger on a 200-amp house panel, but there are some important factors to consider: Load Calculation: You need to ensure that the combined load of all devices and appliances in your house, including the 60-amp charger, doesn't exceed 80% of the capacity of the 200-amp panel. This is in line with the National Electrical Code (NEC) recommendations. An electrician can perform a load calculation to confirm whether your panel can handle the additional load. Dedicated Circuit: The 60-amp charger should be installed on a dedicated circuit to avoid overloading other circuits. Wiring: Ensure the wiring used for the charger is properly rated for a 60-amp load. Consulting with a licensed electrician is the best approach to make sure your panel can safely support the new charger.
@donaldwiley16552 жыл бұрын
What type of tool do you use to loosen or tighten the set screws in the charger?
@tesbros2 жыл бұрын
Hex bit 4MM
@tenjohn231 Жыл бұрын
TEXTBOOK PERFECT
@samsno3667 Жыл бұрын
How come you didn't have neutral wire?
@petermeadows261110 ай бұрын
In this application, the ground is being used as the neutral.
@IvanRamirez-fs3sf Жыл бұрын
Thanks for the video Is it safe to install the wall charger outside? Any updates? Thank you
@tesbros Жыл бұрын
Yes, I’ve had no issues
@CristianGonzalez-hx7lj7 ай бұрын
can you hook up with 100 amp pannel?
@tesbros7 ай бұрын
From my limited knowledge, as long as you have space and power, yes. But you should consult a certified electrician.
@vincentimparato7 ай бұрын
Your electrician should have installed PVC expansion coupling or couplings. Also it looks like his ground wire was unnecessarily oversized. It looks like he used a full size gram of number six, but the code only requires a number 10 which would have saved money on the additionally by the 2020 code is now required to have a GFCI protection to pole breaker at the end of this VO, he mentions putting quad breakers or twin breakers in to make space in the panel. He should’ve mentioned that those twin breakers are many times not permitted to be installed in certain panels. Always follow the UL list at manufactures instructions further note if you didn’t have the breaker panel outside as close as he did, you would also need an outdoor service disconnect within sight of the charger or not more than 50 feet
@bkhoavo2 жыл бұрын
Great vid. I'm seeing 2 hot red and one ground, what happens to the neutral wire? Not needed? Thanks!
@tesbros2 жыл бұрын
Not needed!
@joeee79436 ай бұрын
What is available to charge Tesla drivers to pay for electricity? I have solar panels and I can sell it to Tesla drivers or other ev cars. Looking for the app of there is one to charge money to users. Is this possible?
@BlackStallion-86 Жыл бұрын
Textbook perfect 👍🏼
@edwardpinto79058 ай бұрын
Thank you for the video and saving me a lot of headache
@kranwa15 Жыл бұрын
I guess no white neutral wire for this installation ?
@exsosus50024 ай бұрын
Standard installation today for heavy electric equipment at home: Stove, Washing machine, electric drier, and charging for EV comes with: 1 ground, and 2 hots for USA standard. I believe the hots are always 120v x2. For Sweden where I lived before, its automatically a 220/240 outlet and its 1 hot red which is 240v.
@eastmanresearch31432 жыл бұрын
I would recommend TTHN #4 and you can use a #6 or #8 ground in 3/4" conduit. This will allow you around 76A of capacity if you want to add another wall connector and share the load, that's 38a each. The cost difference for me was about $.50 per foot on the #4 wire TTHN vs. staying w/ TTHN #6.
@keithharrington45952 жыл бұрын
He hired a pro that knew NEC section 625.40 states,. "Each outlet installed for the purpose of charging electric vehicles shall be supplied by an individual branch circuit eat circuit shall have no other outlets."
@keithharrington45952 жыл бұрын
I missed this one: 2020 NEC table 310.16 does rate thhn in the 90 degree column..... #6 @ 75 amps. However, section 110.14 TERMINAL CONNECTIONS rates 100 amp or less breaker terminals at 60 degrees c unless other wise marked on the breaker. This puts whatever wire that is connected to the breaker in the 60 degree column. This changes your wire rating to #6 @ 55 amps. So, in your example, you could connect #3 copper (#3 @ 85 amps) to the breaker then use 90 degree c "terminal lugs" (wire nuts if you will) to connect to the thhn to use the 90 degree c rating just to get your 75 amps on the circuit. Can a Diy'er do all this, yes! Do I recommend they do all that, no! Just use the 60 degree c column and size their wire. The panel above will get unrulely really fast if they jump through those hoops.
@KinGIIRomE Жыл бұрын
Depends if he has a 200amp msp or a 100amp msp.
@Nate_Reed6 ай бұрын
What did this end up running you on the cost to install wall charger and breaker and running the wires?
@wendyfclam13712 жыл бұрын
This installation outside condition, do you need GFCI circuit breaker ?
@tesbros2 жыл бұрын
Great question, but I would ask your electrician about this. They'll be able to explain what you need.
@robertocantero55382 жыл бұрын
I wonder if the wall charger is waterproof?
@tesbros2 жыл бұрын
It’s weatherproof and should withstand the elements.
@3767OF4K2 жыл бұрын
As per state of charge it’s considered a level 3 not 4 which means it’s weather resistant not proof Asper him if you experience an extreme event hurricane etc it will be compromised . I fitted mine with a spare tire cover . The cable actually helps make it round
@3767OF4K2 жыл бұрын
Funny my Wi-Fi won’t stay connected to my phone my iPhone sees the network but says no internet . I was able to update it and adjust the settings but after a few minutes it disappears really strange .
@tesbros2 жыл бұрын
That’s normal. If you want the Wi-Fi to turn on, hold the button on the charger and the Wi-Fi will turn back on.
@3767OF4K2 жыл бұрын
@@tesbros hi thanks for the reply so to change the setting it has a temp access time frame and then times out ?? Also you said you can check stats is there an app or any ways to see what it doing ? Locking it etc . I don’t have my Tesla y yet I have delivery scheduled between 4/11-25 so I’ve got everything installed mats and everything only thing I’m missing is the car lol
@tesbros2 жыл бұрын
@@3767OF4K There isn't an app but once you connect to the wifi access point, you can put the ip address on your manual and you'll be able to access the dashboard. Maybe in the future it'll be more integrated perhaps.
@EdgarFlores-sm1ho6 ай бұрын
W. S. The price instalación??
@KaloPiro-fd7de Жыл бұрын
Hello, can we use the Tesla charger to charge different brands of cars?
@tesbros Жыл бұрын
If you have the right adapter, yes
@family4ev3r7 ай бұрын
with wall charger u installes how long it charge the battery to reach 80%?
@hughgodfrey99336 ай бұрын
At 48a, it can inject 44mi/hr into the car.
@hjc07068 ай бұрын
that's the easiest location to install it. siding/exterior surface mounted breaker/ conduit/ no attic crawl wire dropping through drywall.
@missbell247 Жыл бұрын
Great video installation. 👍🏾
@alton0802 Жыл бұрын
I swear not even an actual electrician can do electrical work without getting criticized. There’s still people in the world that wants to pay you’ll to do this work. It’s fine😂
@bigbawsz2054 Жыл бұрын
Does the green light stay on all day and night when not in use?
@tesbros Жыл бұрын
Yes
@whocare3102 жыл бұрын
how much you get model Y per hr charge on wall charger ?
@tesbros2 жыл бұрын
up to 44 miles per hour
@whocare3102 жыл бұрын
@@tesbros thanks
@garyr75199 ай бұрын
Is a white neutral wire not necessary?
@beerman19578 ай бұрын
Because we use two hot leads (120v x2) which eliminates the common. It is then required to run a ground separately.
@jamesduncan9156 ай бұрын
Expansion joint always on pvc. Shorter runs are not code, but who but it anyways. PVC straps for PVC, this is code
@strokeoftesla11 ай бұрын
What are these individual electrical wires you use? I did not see material on blog either
@DanS-how-to10 ай бұрын
They’re called THHN wires. 6 awg THHN in a conduit is rated for 65 amps so it can go to a 60 amp breaker and charge at 48 amps. If you go with 6 awg NM-B (romex cable), it’s only rated to 55 amps and needs to be powered by 50 amp breaker for a max charging speed of 40 amps.
@Pierre-oshana Жыл бұрын
Hi thax, for the video, can you install it outside? Is it protected from rain /snow /heat
@tesbros Жыл бұрын
Yes
@ashaparekh4941 Жыл бұрын
Is it good idea to install Tesla charger outside of garage or a house ? How was your experience? Was it damaged or stolen because of the outside the house?
@tesbros Жыл бұрын
My experience has been fine - no damage or issues. but I say do what you’re comfortable with.
@rstephe Жыл бұрын
Well done on the wiring. Any concerns or issues with the unit being out doors in regards to weather? No, I do not have an EV. Just trying to learn.
@tesbros Жыл бұрын
We’re glad you’re here! We get some pretty bad storms in Chattanooga and I haven’t had any issues with either of the units I have that are exposed like this
@rkgsd Жыл бұрын
Is it more expensive to have a 60 amp circuit/line installed vs the more popular 50 amp 14-50 outlet?
@tesbros Жыл бұрын
Probably won't be too much more. I would talk to electricians in your area and see what quotes look like.
@pinkiepie1656 Жыл бұрын
I assume you mean nema 14-50
@rkgsd Жыл бұрын
@@pinkiepie1656 fixed
@rrazzorr20006 ай бұрын
What cable was used in this video?
@PedroGonzalez-pc6nb11 күн бұрын
Cooper 60 Amperes
@bohicajohnson720311 ай бұрын
Where is the neutral? Or does it return via the earth?
@DaTecNerd2 жыл бұрын
L1 & L2 are live & neutral or 2 phase live? Because in the country I reside it's Live (hot), Neutral & Ground.... I just want to be sure
@moop_fogo2 жыл бұрын
yes L1 & L2 function as both live and neutral.
@tesbros2 жыл бұрын
@@moop_fogo yes that’s correct.
@keithharrington45952 жыл бұрын
In this country, house power supplies use one transformer and tap or tie into the middle. This allows a 240 vac transformer to supply both 240 and two 120 lines. Some smart guy thought the lower voltage would be safer and the higher voltage would be okay for large loads. So, two hots. The neutral is tied to ground to give it zero potential or zero volts but return the 120 back to it's half of the transformer. Other countries may find this a dumb way to do things. I think it really depends on what you are used to.
@rarebarney568111 ай бұрын
Me feeling like, "this is easy, if he can do it so can I" Later on the new "house blew up with random guy tried to build a charging station in his house and fucked up" lol
@lizbethgonzalez2544 ай бұрын
😂
@ChaseParks3613 ай бұрын
Not rocket science
@Ojeramup129 ай бұрын
What happens if it rains on it? Will it turn off or will the car get electrocuted?
@tesbros9 ай бұрын
No worries, it's waterproof
@anobody570829 күн бұрын
Great info thank you.
@desertcamel357310 ай бұрын
No neutral ?
@meuandu19 ай бұрын
Same thing I’m thinking? I wonder if he used the green wire for neutral
@schizy Жыл бұрын
Attached to [shingle] siding. Any excessive tension on the power cord is going to pull the siding right off the wall. Not a secure attachment or installation. JMHO
@CesarRodriguez-ft6xf4 ай бұрын
What size cable he use?
@rarebarney568111 ай бұрын
Hey what was that tool he used to measure the voltage?
@shanefive010 ай бұрын
Multimeter
@namtao15 Жыл бұрын
Thanks for this video man! Super helpful cheers 🤙
@mintheman7 Жыл бұрын
Only ground, no neutral?
@mightyd422 жыл бұрын
Why is there no common wire? If it was a 240v outlet (like for a dryer), it would be two hots, a ground, and a common. Why is this different?
@tesbros2 жыл бұрын
I’m honestly not sure why. I would check the Tesla manual linked in the description and it might help you out
@y-u-8allthat3372 жыл бұрын
The charger only uses 240 volts it doesn't need 120 something that's using 120v for control wiring in the device itself that's common
@mostafa6852 жыл бұрын
Darren most EVSE are this way. Two hots one ground, neutral isn’t needed because the unit isn’t sending any electricity back to the grid. Now if installing a 1450 receptacle, it’s best to have the neutral installed for future proofing. It wouldn’t be used but, there if needed later on.
@RB-xv4si Жыл бұрын
@@mostafa685 neutral wire has nothing to do with sending electricity to the grid. It’s simply a conductor tapped off the center of the transformer secondary coil. 240v potential line 1 to line 2. 120v potential line 1 to neutral and line 2 to neutral. No neutral needed is because the charger does not need 120v power.
@lmamakos Жыл бұрын
It's like an electric water heater - there's not 110V loads in the device, so you don't need a neutral. That said, it would have been good to torque the terminals as specified in the installation instructions.
@Drbeto209 Жыл бұрын
how much did it cost cuz I have one outside my house also
@neftalirosado61674 ай бұрын
3 wire , same AWG ? # 6 ?
@Mladjasmilic Жыл бұрын
In Europe, due to 3 phase, you can use MUCH thinner wires, as current 3x less for 11kW.
@beerman19578 ай бұрын
Wires should be torqued on the panel.
@zoltrix77792 жыл бұрын
Do you need to perform insulation resistance and loop impedance tests in the US?
@sfevildick2 жыл бұрын
Not at this amperage
@RB-xv4si Жыл бұрын
It’s done often in larger installation but typically not on something like this.
@ismaelnavarro6513 Жыл бұрын
Did he not glue any of the pvc together?
@tesbros Жыл бұрын
he did! he used pvc glue
@GRC7769 Жыл бұрын
No main disconnect required?
@tesbros Жыл бұрын
No external disconnect required, just turn off power at the circuit breaker before installing. Check out pages 2-6 - www.tesla.com/sites/default/files/support/charging/Gen3_WallConnector_Installation_Manual.pdf
@MJHanneman82 Жыл бұрын
The breaker acts as the main disconnect.
@TheElectricMan3 жыл бұрын
thanks for the info
@nafeessiddiqui382 жыл бұрын
How much did the electrician charge (labor) and how much was the parts.
@tesbros2 жыл бұрын
75 per hour for labor and about 250-300 for parts.
@someguy5035 Жыл бұрын
@@tesbros He charged you $250 for some PVC, wires, and a breaker? You got taken to the cleaners. PVC is dirt cheap and you can get 2 pole 50A breakers for under $30. 75ft (2x25ft) of 6 guage copper wire is $90. All in, you're at maybe $150?
@thembones12 Жыл бұрын
@@someguy5035 Most charge $500 for labor only......for installation.....
@mattmccaffrey4299 Жыл бұрын
@@someguy5035 $250-$300 is not a lot for materials for car charger install. Wire is more expensive than you're quoting. Breaker $30 ish. Possibly wall box to pull the wire through $10-$15. All the PVC and / or Romex 4/2 or 6/2 -- it's expensive and adds up. $75 per hour labor is super cheap for quality electrical work. $500 labor is about average (even a bit low) for car charger install.
@jpstreet566011 ай бұрын
Great vid Man !! But is not danger to charge that if it rains ??
@tesbros11 ай бұрын
Nope!
@blueshark009008 Жыл бұрын
I think should install a shield to protect charger, let rain can't wash the charger.
@tesbros Жыл бұрын
It’s totally fine out in the elements, but you can create a shelter for it if it gives you some peace of mind. I’ve seen plenty of people do that too
@hughgodfrey99336 ай бұрын
The charger is rated for outdoor use.
@apa76112 жыл бұрын
Since it’s outside would it need a Gfci breaker?
@gapo62angler932 жыл бұрын
Tesla manual clearly states not to use GFCI.
@user-wl9nz3vy1b2 жыл бұрын
It has a GFCI built in
@keithharrington45952 жыл бұрын
No! Nec 625.54 EVSE (car chargers) attaches a GFCI requirement to the receptacle. Earlier in that section it also requires the charger to have GFCI built in 625.22.
@delinquentgenius88313 ай бұрын
What was the cost of installation
@tesbrosАй бұрын
The cost to hire an electrician to install a Tesla Wall Connector varies based on several factors, including the complexity of the installation, local labor rates, and any additional electrical work required (e.g., upgrading your electrical panel or running a long conduit). Here’s a general breakdown: - Basic Installation: If the wiring and panel are already prepared, installation might range from $300 to $700. - More Complex Installation: If additional wiring, conduit, or panel upgrades are required, the cost can rise to $1,000 to $1,500 or more. Factors like wall material (drywall vs. concrete), distance from the breaker box, and regional electrician rates will impact the final price. Some areas may also require permits, which add to the cost. It’s always a good idea to get multiple quotes from licensed electricians for the most accurate estimate.
@ogunojooluwadamilare Жыл бұрын
Hi ,good day here,please did any one have idea,help me out ,our tesla is showing,charging stopped when ever i plug it on electrical socket。
@tesbros Жыл бұрын
If it's an electrical socket issue, it's most likely that your breaker can't support the charging of a EV. Make sure you have a high enough AMP breaker but I recommend getting the Tesla charger or NEMA installed for faster and safer charging.
@bxu7893 ай бұрын
It seems you hired a professional. It can totally be DIY.
@Phil42069 Жыл бұрын
Anyone have the link to wires?
@GoGetter18 Жыл бұрын
why wasnt the neutral being used?
@pinkiepie1656 Жыл бұрын
EVs only want two hots and a ground. The chargers can run off a straight 240v without 120v.
@michaelkelley75782 жыл бұрын
Are tesla. Chargers built for outdoor winter/rain use. In - 50°C Canadian winters?
@tesbros2 жыл бұрын
Yes they are!
@benkanobe75002 жыл бұрын
So the charging head is 100% weather proof??
@tesbros2 жыл бұрын
Yes, the wall charger is waterproof and is totally fine in the elements.