I made a simple resistance tester for meters that tests them with 1, 10, 100, 1K, 10K, 100K and 1Mohm 1% resistors. I chose 0.5W resistors for the lower ranges and a high voltage resistor for the 1Mohm range to allow for checking insulation testers.
If you want to make a similar tester for electrical installation meters the two most useful resistor values are 1 ohm and 1 megohm. The 1M resistor will need to be rated for 1kV or more for insulation testers that can test at that voltage. It's a good way to check a meter is functioning correctly.
The only time I've seen electrical installation test meters go out of calibration is when they've been abused. Usually involving applying the probes to a live supply and then attempting to do a resistance test on it despite the warning light being lit. Modern meters try to be idiot proof by preventing the test being done, but ironically they are less reliable because of the more complicated circuitry.
The routine calibration thing appeared at the same time as the Part P protection racket was pushed for by organisations who make a LOT of money from it. It's part of the same detached paperwork industry that brought us the five-day electricians certificate. (The same reason meters now need to be idiot proof.)
It's reassuring to see that my old American-made Fluke from around the early 1990's is still reading accurately.
If you enjoy these videos you can help support the channel with a dollar for coffee, cookies and random gadgets for disassembly at:-
www.bigclive.co...
This also keeps the channel independent of KZbin's advertising algorithms allowing it to be a bit more dangerous and naughty.

Пікірлер: 524
@timg375
@timg375 5 жыл бұрын
I love my trusty Fluke meter. Got it free from College as the were getting new ones so the department chair gave the older ones to us Electrical students.
@bennylloyd-willner9667
@bennylloyd-willner9667 5 жыл бұрын
Did they know they gave them away 😉
@heroslippy6666
@heroslippy6666 5 жыл бұрын
I love it when schools give old stuff to students. From my highschool I ended up with Modern Biology by moon mann otto from the 1950's. Also a few programming books, Computer Confidence, 2 for basic, 1 for basic plus, 2 for pascal, and 1 for fortran. Now these languages are worthless to modern day highschoolers with smart phones, but I like retro and programming so they're pretty cool.
@aaronbrandenburg2441
@aaronbrandenburg2441 5 жыл бұрын
Had friends at school dancing terms with the school signed a waiver or to. Put this way used to have an Electronics lab. Excetera excetera. Good times. High School in the 90s.
@christopher88719
@christopher88719 5 жыл бұрын
Big Clive, you are so right when you say you just know when your meter 'is giving rogue readings'. You kinda develop a gut intuition on things after you been around meters long enough.
@1marcelfilms
@1marcelfilms Жыл бұрын
when the switch is inbetween settings
@phillyphakename1255
@phillyphakename1255 8 ай бұрын
You never fully trust the meter to show you the whole picture, always taking it with a little bit of skepticism. The goal of having a Fluke is to make that trust a little bit stronger, whereas the 5 dollar multimeter will have near zero trust.
@Storm-tg8rx
@Storm-tg8rx 5 жыл бұрын
Friend: "What did you do today?" Me: "I watched a guy plug things in for 20 minutes"
@sephirothsoul999
@sephirothsoul999 4 жыл бұрын
"porn?"
@JUANKERR2000
@JUANKERR2000 4 жыл бұрын
@@sephirothsoul999 Yes, he was screwing his nuts!
@DigitalYojimbo
@DigitalYojimbo 5 жыл бұрын
Can we get a teardown of the robin dmm; so that we may see what went wrong ?
@BoB4jjjjs
@BoB4jjjjs 5 жыл бұрын
That might be good, but there might be nothing to see. It might be internal within the chip!
@lumpyfishgravy
@lumpyfishgravy 5 жыл бұрын
That'll be fun. Taking them apart is fairly easy, but fiddly to get back together. What's my money on? Intermittent rotary switch or overloaded part somewhere in the 200mA low impedance loop. I guess that's the first thing I'd check: is it chucking out at least 4V O/C and 200mA S/C. I assume the cal lab would have checked the fuse, which is usually user-replaceable for *reasons.*
@mrfluffytailthethird
@mrfluffytailthethird 5 жыл бұрын
Then he needs an electron microscope Probably going have to get one from Alibaba instead of ebay
@davey2k12
@davey2k12 5 жыл бұрын
It's them crap Kodak battery's from poundland powering the robin FFS
@bennylloyd-willner9667
@bennylloyd-willner9667 5 жыл бұрын
@@BoB4jjjjs but that's not the BigClive way of doing things is it? "it MIGHT not be visible" 😁 If it in any way can be taken apart, it means it should be taken apart!
@656hookemhorns
@656hookemhorns 5 жыл бұрын
Who else was waiting with anticipation for the cheapy yellow meter?
@maicod
@maicod 5 жыл бұрын
me me me in the tune of adafruit ;)
@flex209
@flex209 5 жыл бұрын
To be honest, I kinda want to see it go "bang"... And I'm sure that Clive can make it happen in a controlled manner.
@ehsnils
@ehsnils 4 жыл бұрын
Since I have one myself it was nice to see that it was decent. And for most practical purposes a decent meter is what you want since most circuits do work within 10% tolerance range and this was better than that. The downside with that cheapy yellow meter is that you have to open it to replace the battery, which is a vanilla 9V battery. I did put in a lithium one in mine to ensure long life. But I did discover that when the battery starts to run flat the meter starts to give weird measurements, but that's common for most electronics - bad power supply can cause all kinds of strange problems.
@PavelGrund
@PavelGrund 3 жыл бұрын
Suggestion: Instead of using absolutely accurate 100k resistor (which you may not have on hand) in that gadget you can use two parallel 200k or four 100k (two parallel sets of two resistors in series) and match them so they give you bang on value instead of sticker, that 100k is actually 99,69 kΩ. Like that: 1 / (1 / 203,0 + 1/ 197,1) = 100,0032 or 1 / (1 / (99,84 + 100,78) + 1 / (99,73 + 99,66)) = 100,0015
@lwilton
@lwilton 5 жыл бұрын
Considering that 50 years ago your normal serviceman's analog meter was typically 3% for a good meter and 5% or worse for a cheap meter, having just about anything being within 1% over the whole range is really pretty darn impressive. Of course its also worth noting that the world itself is pretty much a 10% thing, and 1% is overkill for most measurements. It gives modern people a false sense of worry when something is off by 2%.
@johnpossum556
@johnpossum556 5 жыл бұрын
50 years ago resistors were 20% tolerance, too.
@markrainford1219
@markrainford1219 5 жыл бұрын
And they still managed to land on the Moon.
@tinplategeek1058
@tinplategeek1058 5 жыл бұрын
@@markrainford1219 Allegedly (runs away and ducks for cover) 😉
@2lefThumbs
@2lefThumbs 5 жыл бұрын
@@tinplategeek1058 rofl
@chrisengland5523
@chrisengland5523 2 жыл бұрын
The bigger problem is that many people confuse accuracy and resolution. Just because a meter shows 4 digits, doesn't mean that it's accurate to 0.1%, yet that's how many folk understand it. In practice, great accuracy is rarely needed. What's more important is relative accuracy - when measuring two voltages, it often suffices to know which one is highest. For example, is the input signal above or below the supply voltage?
@LazerLord10
@LazerLord10 5 жыл бұрын
Hmm... This gives me something to do with the 0.01% 5K resistors that were in the junk bin at work. (also, those things were $7 apiece, and they're 0603!)
@dl5244
@dl5244 3 жыл бұрын
"Metal Foil" (laser trimmed) is my guess. Rock solid too
@davidprice2861
@davidprice2861 5 жыл бұрын
Totally agree regarding Uni-T meter, very useful, very accurate and nifty.
@Christian_Banks
@Christian_Banks 5 жыл бұрын
The first time you showed that meter with the DC current clamp I looked one up and bought it. Amazing thing to have.
@boggisthecat
@boggisthecat 5 жыл бұрын
Christian Banks Yes, it’s twitchy for low DC current but otherwise works well. I checked mine against our calibration equipment and it was well within specification - not always the case for cheap Chinese meters.
@Tn18d
@Tn18d 5 жыл бұрын
I've had one for about 2 years now and I use it at work every day, brilliant meter, I might get another to keep in the car
@Tn18d
@Tn18d 5 жыл бұрын
I've had one for about 2 years now and I use it at work every day, brilliant meter, I might get another to keep in the car
@jonathanellis3169
@jonathanellis3169 2 жыл бұрын
Thank you Big Clive, for the little mention about the UT210E's Clamp based DC ammeter. Just been trying to find a meter to help me find a slow drain on a car, and having looked at many reviews of similarly priced and more expensive meters I think I'll be buying that one.
@zx8401ztv
@zx8401ztv 5 жыл бұрын
The 830b yellow and similar one is basically an ICL7106 chip from millions of years ago. There is a 100mv ref set pot inside for the voltage and current. Resistance uses a ratio metric method,.
@peterburi2727
@peterburi2727 3 жыл бұрын
I also have a Fluke 23.That has been my go to meter. A real workhorse and extremely rugged guy.
@reddog694uk
@reddog694uk 2 жыл бұрын
Having researched the cost of good decade boxes, i have resigned myself that a design such as yours is currently the only way forward for non-professionals like myself and i like your design very much. Well Done !!
@sparkyprojects
@sparkyprojects 5 жыл бұрын
Took our meters to a wholesaler where they had a calibration day, the basics are a free calibrationn 'test' and a sticker to say it's within spec. But they also offered 'calibration' to put it right if needed the calibration company was Robin, and they'd even accept other makes.
@scriptguru4669
@scriptguru4669 5 жыл бұрын
Can't fault Robin, my fluke/robin 1653 MFT tester has been going strong for 10 years
@lumpyfishgravy
@lumpyfishgravy 5 жыл бұрын
@@scriptguru4669 That's a very early model, I suspect more than 10 years!
@FireAngelOfLondon
@FireAngelOfLondon 5 жыл бұрын
This is a really helpful video, especially for anyone starting out who wants to know if a cheap meter will be adequate until they can afford a better one. The answer nowadays seems to be "Yes."
@bigclivedotcom
@bigclivedotcom 5 жыл бұрын
Yes it is. I recommend starting with a cheap meter and then moving up to a better one when you decide what features are most useful to you.
@carlubambi5541
@carlubambi5541 Жыл бұрын
Great to have a resistor and capacitor reference test bed .Essential
@dj_paultuk7052
@dj_paultuk7052 5 жыл бұрын
I have a very similar Fluke to yours, i have the 77. Which was given to me at the end of my MoD apprenticeship 28yrs ago. It still works absolutely perfect. As you say, the Daddy of meters.
@monadking2761
@monadking2761 5 жыл бұрын
Nice functional test for testing meters. It brought back memories. I was in the field of Metrology at a magor helicopter company before my broadcast career. Most analog meters are tested at full scale and digital too with standards. We used to test the electricians meters functionally like what you did and sticker it accordingly but, anything that touch the aircraft they had to be calibrated correctly. We would take reading at multiple points of the ranges with before data and if we did adjust, we had to have after data for traceability under NIST then under ISO 9000 and shorten the cycle time of the meter being used then find out if that meter was used on anything that was critical. It was a pain but interesting work. If you want an accuracy test use a Kelvin 4 wire bench ohmmeter. It uses the voltage drop method to display resistance on your lower resistances ranges with gold clips. I remember measuring conduction levels of connections of pins and measuring down to 10 to minus 9th place one time for repeatable tests because of a claim that the pins would ware after so many uses and the resistance would change. Just to prove Cramolin (ProGold) on connectors work better. It was weeks of testing and taking data.
@raymondmucklow3793
@raymondmucklow3793 5 жыл бұрын
Well done, my dad had a fluke the entire time I was growing up, I dont know the model number but it had this fantastic grey soft but able to provide protection case. Super thick. He also has 77 III model I'm supposed to put it back together for him. The first one crapped out a few year ago battery acid if I remember right. Cheers from the hot muggy kansas.I'm still working on that transmission. Just fyi.
@tomgeorge3726
@tomgeorge3726 5 жыл бұрын
We here in Australia have a similar yearly cal check for some industries and government contractors. I use a NATA calibrated meter and standards to do the tests. I have found that most, almost 99% of DMM are still good 5 to 10 years after purchase, even the lower (not elcheepo) China products. unless they have been damaged due to high volt or current. The insulation tester, that failure is not uncommon among most of the brands, possibly caused by connection to a live circuit. Even though they can be expensive, they are usually a throw out item. These days with the low cost of high precision resistors its not hard to make a simple resistance checker unit. Good video mate..
@j.cheeverloophole9029
@j.cheeverloophole9029 5 жыл бұрын
I bought one of those TackLife meters a couple of months back, amazing value, measures everything incl temperature...all for little more than i paid for my el-cheapo meter some 15+ years ago
@simontay4851
@simontay4851 5 жыл бұрын
I bet it doesn't measure inductance and/or ESR.
@n7565j
@n7565j 5 жыл бұрын
Harbor Freight here in the US gives those cheap meters away for free on occasion, I've got one in every car and my GoldWing too... Hard to beat free, and if it bites the bullet, get another ;-) They actually seem to work surprisingly well too... Great test!!! Amazing how accurate even the cheap meters are! I've got a rather expensive DC Clamp Amp meter as well for diagnosing auto issues, VERY handy indeed!!!
@Zenodilodon
@Zenodilodon 5 жыл бұрын
Today my neighbor told me he had an $800 snap on meter. I laughed and said, I have a Fluke 73...
@nogravitas7585
@nogravitas7585 5 жыл бұрын
Eight hundred dollary doos? I hope it doubles as a scan tool.
@bostedtap8399
@bostedtap8399 5 жыл бұрын
Most likely really big digits!, probably some graphing ability. But, yes, Fluke does the job.
@Zenodilodon
@Zenodilodon 5 жыл бұрын
@@nogravitas7585 doubles as a wallet scanning tool.
@boggisthecat
@boggisthecat 5 жыл бұрын
Zenodilodon Not true RMS, but a solid meter. We still get a few come into our calibration lab, and they never fail to meet spec despite being very old instruments. I wonder who Snap-on’s OEM is for multimeters.
@Zenodilodon
@Zenodilodon 5 жыл бұрын
@@boggisthecat I love how fast they are, I find a lot of other meters to be really slow and based on averaging during reading. I have seen meter averaging so bad it will shoot up double or more before finding a stable reading. I have next to no complaints when using a fluke. I like the fact they are work horses.
@CrimeVid
@CrimeVid 5 жыл бұрын
my Uni-T was delivered just before I found this video, you have given me some confidence in what is a very reasonably priced bit of kit !
@bigclivedotcom
@bigclivedotcom 5 жыл бұрын
If you bought the Uni-T UT210E then you have one of the best meters around.
@CrimeVid
@CrimeVid 5 жыл бұрын
bigclivedotcom what do you do to make these horrid little leaflets readable, my eyes are not as young as they were. Is there a downloadable/printable copy available ? Otherwise I’m going to have to learn to use the Gdam printer again !!
@notyoung
@notyoung 5 жыл бұрын
I saw my first Fluke digital meter demonstrated at the local electronics distributor many years ago, including putting the "soft" cover on it and dropping it five feet to a concrete floor. You know the guy selling the meter has great faith in the maker's claims when he does that ;-) Even the cheap ($8US to free) meters from Harbor Freight are reasonably accurate once calibrated, using the most accurate of the AD584 chips (AD584K, with its rated +/- 10mv on its 10.000 volt output - even better with a traceable calibration). If the cheap meter's calibration pot is gently eased to show 10.00 volts *steadily*, then it's within +/-5 mv of the AD584's 10.000 volts. That's more than adequate for checking 12 volt batteries in the small solar systems I dabble in. Biggest so far had 540AH of AGM batteries and 1600 watts of solar and smallest is a shed lighting system with 15AH of battery and a single 30 watt solar panel. If the cheap meter reads 10.00 volts from the AD584, then the desired float voltage of 13.65 volts is very close when the cheap meter shows 13.65 volts - and I'm not out much if the meter takes a 20 foot tumble plus calibration of another of those meters takes maybe 5 minutes ;-)
@Crushonius
@Crushonius 5 жыл бұрын
thanks for the ut210e recommendation that thing is incredible and so cheap that its a must have
@andrewwilson8317
@andrewwilson8317 5 жыл бұрын
I have a lovely old AVOmoving coil meter that lives on the shelf over my bench.i have checked it against a calibrated decade resistance box and it's dead on. Back in the day it would of been very expensive. Now can get same level of accuracy from a ten quid digital meter!
@isettech
@isettech 5 жыл бұрын
At one time I had a 1,000,000 Megohm resistor. It was in a radiation detector as part of the resistance bridge to measure the resistance of air. When air ionizes, the disassociated electrons migrate towards a positively charged plate in the chamber. This was an alternative to the Geiger Muller avalanche tube to detect ionizing radiation. It was stolen from storage.
@NOWThatsRichy
@NOWThatsRichy 5 жыл бұрын
Interesting vid, as I remember making a similar resistance box when I was at collage, way back in 1984! A slightly more complex unit, it was called a decade box, all the various resistors were hard wired inside & a rotary switch was used to change the resistance to the output terminals, which were connected to the device under test. I then worked for a year in the equipment calibration & repair lab of a well known defence & space company (Marconi systems), all the test gear could be traced back to the National physics laboratory. Very interesting work, some of it was covered by the Official secrets act!
@aspectcarl
@aspectcarl 5 жыл бұрын
A man can never have enough meters 👍
@johnfrancisdoe1563
@johnfrancisdoe1563 5 жыл бұрын
Carl Richards Nah, anything above 2 (3 as a reach) gets impractical in a world built for those with less.
@daverhodes382
@daverhodes382 5 жыл бұрын
@@johnfrancisdoe1563 Don't be silly now.
@FarleyHillBilly
@FarleyHillBilly 5 жыл бұрын
@@johnfrancisdoe1563 You can use a LED as a cheap alternative
@Cadwaladr
@Cadwaladr 5 жыл бұрын
I bought one of those Uni-T clamp meters because I saw you using it. I love that little guy.
@alexmarshall4331
@alexmarshall4331 5 жыл бұрын
hahaha HAHAHA HEHEHEHEHE south east London.. It's Saturday morning..it's my birthday..it's really sunny..London Pride today...and I've just watch Our Man on the Isle of Man check the calibration on his multimeter collection...FANTASTIC WHAT A START TO THE DAY...THANKYOU BIG CLIVE💎💎💎💎💎👍👜
@shrikedecil
@shrikedecil 5 жыл бұрын
ROBRENZ has a series of videos on making a much more extreme version of that resistor box. The point being more along the lines of "Make any conceivable resistance, accurately and precisely". But, conceptually, still a box of resistors.
@ianbutler1983
@ianbutler1983 5 жыл бұрын
We have a chain here in the US called Harbor Freight. They sell mostly very cheap Chinese tools, lawn sprinklers that look like frogs, and tarps, etc.. They often have coupons for free items, and I have got 3 DMM's from them for free. They are amazingly accurate. I would have killed for one when I was a kid.
@stuartmcconnachie
@stuartmcconnachie 5 жыл бұрын
Don’t tell me.... you just couldn’t resist making a video? Ohm my god!
@AndrewGillard
@AndrewGillard 5 жыл бұрын
Does your yellow "cheapy meter" maybe have a half-dead battery, by any chance? (They use 9V/PP3 batteries IIRC - I have that same model, which was my first ever meter around 15 years ago!) I'm totally speculating, but it wouldn't surprise me if it struggled to measure higher resistances when its power source wasn't quite at the voltage it was expecting... (I've recently bought a few 0.01% resistors with very low thermal coefficients, which are fun! They're around £5-15 each, and you can't get higher values with that level of tolerance from regular suppliers (they're special orders from Vishay and the like), but they're a relatively cheap way of getting an idea of the accuracy of your meter(s) when you don't have a high-accuracy meter to act as your reference. Likewise I'm getting some tight-tolerance voltage references for the same reason. I'm on a bit of a metrology obsession atm! 😹)
@thephilpott2194
@thephilpott2194 5 жыл бұрын
The yellow hobby £5 cheapy DT830 and their related clones do shit themselves eventually. If mine is anything to go by, after a number of years of good service, one by one the ranges have a nervous breakdown, the screen shows extra decimal points, then it's goodnight vienna. The leads are generally cack from day one, and need throwing away.
@andymouse
@andymouse 5 жыл бұрын
you and me both! Metrology can really take a hold of you, I am building Dave Jones's (EEVblog) micro current box at the mo so I can add a Nanoamp scale to my fluke 79 meter, he wrote a fascinating article all about the theory of operation, that's a great read! I also have been buying 0.01% resistors for the build. For me it all started from wanting to no exactly how much current my Arduino draws when "asleep" now its getting out of control! I wish I had the kit that he has, also, Marco Reps is another guy who loves his Metrology. I just no I'm gonna want to test the calibration of the calibrated calibrator ! Wonder if there's professional help for me ? Voltage references are another step along the path that is precision. Stuff like measuring the current generated when you shine a light on an LED or how many lemons and bits of zinc to power a Atmega328p-AU all await me!...good luck with your experiments!
@Vladimir-hq1ne
@Vladimir-hq1ne 5 жыл бұрын
Actually you can order less than 0.001% R tolerance ceramic arc-in-noble-gas-coated alloy resistors. But they are vacuum-tubed and aren't tolerate high currents. And - not from ordinary bulk suppliers, obviously. Prices at all times were comparable to ordinar mid-range family car for the 4 of these.
@lwilton
@lwilton 5 жыл бұрын
There are instrument calibration services available, but they charge a fair amount of money. Which is reasonable, considering the equipment they have, the environment they have to keep it in, and that they have to pay people that actually know what they are doing to use it.
@NiHaoMike64
@NiHaoMike64 5 жыл бұрын
@@thephilpott2194 Try turning the dial a bunch of times to clean the contacts. I have a not so cheap Mastech that had an intermittent dial switch, ended up cleaning it with Deoxit to make it usable again.
@harrilumme1875
@harrilumme1875 5 жыл бұрын
Yes, it is a common misconception that calibration involves some kind of adjustment. Calibration means comparison with a certified traceable reference (in this case reference resistance). The calibration certificate lists the measured values in a table with the calculated uncertainty of measurement. Not a mere yes or no. Actually not any kind of pass or fail, unless the equipment has official requirement like the kilowatt-hour meters for electrical energy companies.
@stefantrethan
@stefantrethan 5 жыл бұрын
As much as we'd like to watch you play with your nuts for hours, MultiContact specially makes a set of drivers that will have you finish in no time at all. They are made in Switzerland and thus unaffordable, but easy to copy yourself. Just take a suitable piece of pipe that fits over the thread and file a step back on both sides, so two prongs are left which mate with the slots in the nut. If you look down into the socket side you will further spot similar recesses in the bottom that accept a driver made from a smaller pipe. This one is not strictly needed, but it is always best to have a something to stick into the other hole.
@nutbastard
@nutbastard 3 жыл бұрын
I'm currently watching this video, and I don't know if I have the capacity to resist finishing it. You really lead the way, and you're always opening gates for young minds who might have reluctance towards being induced to appreciate these kinds of fields. I love how you charge in without any filter and we're lucky to have you on a platform that presents no interference in your content. I'm always alternately oscillating between you and AvE, and it's nice to have this content directly available.
@mcsniper77
@mcsniper77 5 жыл бұрын
I'm would have though you would have purchased the 211b for the higher resolution. If anyone could justify it, that would be you. Your gear choices are so practical. You are like anti Dave when it comes to equipment. Love your work, keep them coming,
@paulstaf
@paulstaf 5 жыл бұрын
I have that same UNI-T meter...I keep it in my backpack when I travel....awesome meter for the $$.
@joelmorton418
@joelmorton418 5 жыл бұрын
If you want to use decent leads with the cheap meters, all you have to do is trim off the shrouds with a utility knife and then use wire cutters to cut off the little plastic button at the end of the conductor that makes the connection. I use a lot of the cheap meters since my students don't really understand concepts like "things break if you use them wrong," but the leads that come with them don't last nearly as long as the meters do even with normal use. I can buy ten or twelve eight or nine dollar meters a year even out of pocket if I have to, but I usually only need to replace two or three a year. The leads they come with, though, are terrible, and don't always work right out of the box.
@TWX1138
@TWX1138 5 жыл бұрын
I have one of those little yellow meters, sold in a red plastic case in the United States through Harbor Freight. Unfortunately it has gone out of calibration for AC volts, testing a residential electrical socket, which should net a reading between 115 and 125V, got 145V. Testing with a better meter got a proper reading. So I basically only use that meter to confirm the presence of electricity, not for what any actual values are.
@singeslayer8367
@singeslayer8367 5 жыл бұрын
So many toys and all of them work fine. Very nice.
@jeremytoms5163
@jeremytoms5163 3 жыл бұрын
I was replacing lighting at a company that offered meter calibration. After getting all our meters recalibrated for free ( when to the pub with the technician at lunchtime! ) I brought in my very old, brown bakalite, hand cranked, insulation tester for a laugh. I'd had it from my apprentice days when it was third or forth hand when I got it and had had it in the van to show the apprentice along with those immortal lines of "just hold these clips for me and this won't hurt ". So he put through the calibration test on both continuity and insulation and the damn thing passed! Still have it along with its certificate, was fun on sites when the work was inspected and they wanted to see the meters and their calibration certificates. Inspectors just don't have a sense of humour anymore.
@bigclivedotcom
@bigclivedotcom 3 жыл бұрын
Most of the new era of inspectors are just a made up job to keep people employed.
@jeremytoms5163
@jeremytoms5163 3 жыл бұрын
Oh yes ! Many, many tales of that. In one the contractors were installing new emergency lighting in a battery room in steel 20mm conduit. Every bend was formed by 20mm flexible conduit. Client couldn't understand my fuss, although they did agree to run a seperate cpc through the conduit after I said I was quite happy to take the padlock isolation keys home with me if they didn't. Turns out that on a crew of 20 sparks on site, 5 were qualified. The rest were either 6 week wonder boys or actual apprentices. Guess who ended up checking all their work afterwards, even though their own inspectors said it complied ?
@dhaen
@dhaen 3 жыл бұрын
As a sweaty youth, if I held the clips tight I felt almost nothing, while the person turning the Megger handle struggled.
@GrayMatter70
@GrayMatter70 5 жыл бұрын
Your AMECaL ST-9905 didn't make the cut? I got myself one of those after seeing your videos because I liked the big screen.
@chloehennessey6813
@chloehennessey6813 5 жыл бұрын
Saved up for a month and got myself a Fluke 87 and an electronics starter kit off Amazon. Snapelectronics is the set I got. Pretty neat so for! It looks like it was mainly designed for kids younger than me; but it works P.S I also have that red clamp/meter by UniT! My uncle John gave it to me. Well he let me use it at his office and than said take it home and practice with it. Than he gave it to me. Anyways thanks for these videos Mr Clive. I’m a gymnastics teen. It’s literally my world. Not by choice. Your voice is soothing and your content is teaching me to boot. So I get a win win by watching this. I can shrug off my day and relax. I know I’m a weird girl. But engineering and pixie wrangling run in the family.
@bigclivedotcom
@bigclivedotcom 5 жыл бұрын
Weird is always a good result. Most technically inclined people come across as weird.
@chloehennessey6813
@chloehennessey6813 5 жыл бұрын
Matt Quinn I did not know he had any! AvE recommends him as well so that’s two people. I’m going to look in to it. Thanks!
@ArumesYT
@ArumesYT 5 жыл бұрын
I used to have one of those cheap things, looks suspiciously equal to the D03047 (the one you call CPC, mine was branded as a Grant). They sell for about 7 pounds nowadays, even cheaper than (other) Chinese junk, but surprisingly accurate. It's an OEM design sold under lots of brands and unbranded versions. Note how similar it is to the yellow M-830B. Used mine for about 15 years until it finally broke just two weeks ago, suddenly giving the same rogue readings as the Robin that failed the calibration test. Best value for money I ever had. :-) Despite the excellent experience I still decided to get something a bit more expensive now just for the comfort of having auto range.
@johnhodgson5313
@johnhodgson5313 5 жыл бұрын
The accuracy of cheap digital meters is great. I checked the calibration on many meters where I work and the cheapies aren't tough but they are more than adequately accurate for most jobs. I was just checking a Simpson 260-7 scale and with an tolerance of "2 degrees of arc" you wouldn't have been able to beat the digitals that were half the price for accuracy. (For those who've never heard of a Simpson 260, they were the Fluke 87's of the analogue VOM's)I think your government program is what we call a calibration check rather than a calibration. The meter either meets its spec or fails, no adjustment.
@UpcycleElectronics
@UpcycleElectronics 5 жыл бұрын
I just received a meter from AliEx sold as an A830L. It's blue and grey and looks a bit updated from the old yellow cheapy you used here. I got it for the enclosure. Inside it's pretty much identical to the cheapest yellow meter. It's just another ultra basic build of an ICL7106 based meter. The one I got was $4.61 shipped. It's also got a slightly larger display with a backlight. Acetone strips the silkscreen completely too. It's a nice enclosure for under $5 :-) -Jake
@BoB4jjjjs
@BoB4jjjjs 5 жыл бұрын
Excellent, even the el-cheapo meter passed with a respectable reading, though I might not want to hold the leads at very high voltage! EDIT:- Or high current!
@jamesplotkin4674
@jamesplotkin4674 5 жыл бұрын
Likely this chea-poo meter has a low ohms-per-volt rating. Fine for resistance and voltage readings where the device won't bring down the numbers, such as mains voltage.
@bigclivedotcom
@bigclivedotcom 5 жыл бұрын
The rubber holster cheapo meter wins points for having two 20mm ceramic fuses. 500mA for the low current ranges and 5A for the lower than normal 5A range. Their safe breaking capacity is around 1500A.
@BoB4jjjjs
@BoB4jjjjs 5 жыл бұрын
@@bigclivedotcom Excellent, even better. I must look out my meter I have like that again, though I can't get near my workshop for stored stuff at the moment. This has to change! I may have left the battery in it, not good, it will have leaked by now!
@gilwyckmans
@gilwyckmans 5 жыл бұрын
What about the quality of the inside insulation of the different meters? I saw some that have less than 2 mm insulation between circuit board tracks used to measure voltages on multi MW 400 V power supplies. Some guys don't want to stay alive! Don't need to mention that those meters usually only have 250 V glass fuses...
@Bartok_J
@Bartok_J 2 жыл бұрын
Good to see that the cheap and cheerful meters are almost as accurate as the posh ones. The unusual ranges (6v etc) on the Taclife reminded me of the Russian meters (mechanical) that used to be sold cheap. They tended to have unusual ranges like 3v, 30v etc, that frequently meant having to multiply the scale reading by four. They weren't nice. :-(
@davemoore5222
@davemoore5222 2 жыл бұрын
A number of Fluke meters had ranges such as 6, 60, 600. Certainly Fluke models 11x. We had many 115s at work, and I owned a 117, which now costs twice what I paid for mine.
@QoraxAudio
@QoraxAudio 5 жыл бұрын
Bought a basic Fluke 115 about two years ago. Still was about 200 euros. Even while those aren't made over here anymore. Fluke factory and development department used to be about 12 kilometers from my home. When it comes to EMC measurement equipment, calibration is a bit more of a fuzz. Calibration labs have to be certified specifically for EMC equipment. Some Schaffner/Teseq equipment even needs to be sent to some lab in Switzerland for calibration and adjustment.
@mlight6275
@mlight6275 5 жыл бұрын
i have a time electronics resistance box i bought at a boot sale from an old engineers, with 2 variable psu's for £25. good old fashioned sturdy quality equipment.
@redcrow2006
@redcrow2006 5 жыл бұрын
I use a cheap meter all the time. Never fails. I've got a fancy fluke with a detachable screen but it absolutely murders batteries and every time I went to use it it was dead. So I use the cheap one.
@jeffflowers5489
@jeffflowers5489 5 жыл бұрын
I've always been a Fluke fan. In the old days I always wanted a big black Simpson meter.
@PaulMansfield
@PaulMansfield 5 жыл бұрын
If you made a box with 1, 2,4,8,16 etc resistors in a chain, with bypass jumpers, you could dial in any resistance you want.
@brian9731
@brian9731 5 жыл бұрын
I test the calibration of mutimeters at work for the alarms and security systems industry. We use a calibration kit from ACT Meters. In the kit is a test box for checking Ohms, volts and amps and a multimeter which is externally calibrated in our case, by RS components. I have always thought that this is a bit of a waste of time for digital multimeters because they generally don't go out of calibration. ACT supply a calibration certificate template which states that anything + or - 5% from that measured by the externally calibrated meter is acceptable.
@jamesharmer9293
@jamesharmer9293 5 жыл бұрын
Always liked the Fluke meters myself. When I worked at BT that's what we used.
@Pknuckles1804
@Pknuckles1804 5 жыл бұрын
Can't go wrong with a Fluke. I've had my 88 used professionally since 2003.
@phils4634
@phils4634 5 жыл бұрын
Uni-Trend stuff is pretty excellent, and awesomely excellent for the cost! Mind you they do some seriously costly "professional" equipment too, especially their range of higher-end digital 'scopes such as their 800 MHz UTD5082C - over $8000 in Australia. For low-range resistance testing, it can be useful to give the lead plugs a quick squirt of contact cleaner / lubricant. Helps a lot (especially on the cheaper meters with no null capability)
@Markus0021
@Markus0021 5 жыл бұрын
The little cheapie meters actually did better than I thought they would. Technology has come a long way. The old $10 analog meters from the 60's and 70's were virtually useless.
@acmefixer1
@acmefixer1 5 жыл бұрын
Mark L said "... analog meters were virtually useless." Useless to you, maybe because you didn't know how to use them properly. They can do an adequate job if the user understands their limitations.
@Markus0021
@Markus0021 5 жыл бұрын
@@acmefixer1 You understand that I was specifically talking about the $10 analog meters manufactured in the 1960's, right? I fully know how to use them, and was old enough back then to use them correctly. But using the analog resistance range on a meter with only one resistance range, or maybe 2, meant that you could not tell the difference between a 50K resistance and a 75K resistance, for example. I was happy when I saved enough to buy a $30 analog meter, which was much more useful and reliable.
@m.k.8158
@m.k.8158 5 жыл бұрын
@@Markus0021 another issue with most of those low-end analog meters was that generally they were low impedance/resistance(1000 or 2000 ohms per volt), so they had to be used with care, as circuit loading could skew the readings, and might even disturb the operation of the circuit(which could skew the readings even worse).
@Markus0021
@Markus0021 5 жыл бұрын
@@m.k.8158 Very true. I can remember encountering this problem several times before moving on to a better meter.
@ehsnils
@ehsnils 4 жыл бұрын
What we now are anticipating is a check of the voltage and current accuracy as well.
@Xoutdoors
@Xoutdoors 5 жыл бұрын
Some applications here in the US we have to send meters in for calibration. Mostly Aviation and things where safety is a huge thing.
@superdau
@superdau 5 жыл бұрын
As you always say (or was it AvE?), none gets fired for buying a Fluke. But for home use it is totally unnecessary to go for an expensive meter (but I wouldn't hold one of the cheapest meters in my hand while poking around at mains). I have Vichy/VC99. For the 30$ it was then it is well worth its money. Huge digits and over a decade old now I think. It gave me weird readings once in all that time a few years ago (and yeah, you "feel" if something is off). I cotton swabbed the PCB contacts uder the dial and it has been fine again ever since. While I have decent (but now outdated) Tektronix analog scope and a Hameg function generator, I'm using a cheap STM32 based scope (a JYE tech "DSO shell") and an even cheaper ebay function generator much more often for quick trouble shooting in repairs and debuging than the "big" tools. There's a lot of brand snobbery going on my cheap devices have been called tools. I just found that they do 95% of the things I need at 5% of the price.
@edgeeffect
@edgeeffect 5 жыл бұрын
It's good to see you testing meters down in my tight-wad price range.... 'specially that you've found them to be "not actually that crap at all"
@donaldasayers
@donaldasayers 5 жыл бұрын
I have an old Fluke 73m had it from new in 88. I ran over it with the car. If it had been face up it would have been OK, but face down a piece of gravel cracked the screen, still worked though. Phoned Fluke, they wanted it for their museum of disasters that happen to Flukes and they survive, but they eventually sold me a new screen.
@steve6375
@steve6375 2 жыл бұрын
I would use large 50W resistors for 1R and 10R (and add a 20R and 50R too) so it could be used as a load and will allow you to test calibration of PSU ammeters too.
@boggisthecat
@boggisthecat 5 жыл бұрын
9:00 - ‘Calibration’ differs from adjustment. Calibration gives you information, which could be a pass/fail for some requirements but is typically a set of data. For example, if your 1 ohm resistor was 1.001 +/- 0.002 ohm and you used a meter that yielded ‘1.01 ohm’ you would get a test result for verification at 1 ohm: ‘1.00 ohm applied, 1.01 ohm indicated, 0.01 ohm uncertainty’ and usually the specification and a compliance statement. The calibration standards used to verify multimeters are not cheap to buy or maintain, so costs can be fairly significant.
@cmonster6
@cmonster6 5 жыл бұрын
The Mastech meter you tested is available from our local Chinese tool importer here in the US and is actually a quite good little meter for all around use.about 5.99 US dollars
@bramslootweg
@bramslootweg Жыл бұрын
You must have gone "nuts" building this....
@BedsitBob
@BedsitBob Жыл бұрын
You can get replacement lead sets quite cheaply. I recently bought one of the Parkside (ie. Llidl) auto ranging Multimeters, and I wasn't impressed with the leads, so I got a replacement set (complete with removable crocodile clips), for £8.
@ashleysmith110
@ashleysmith110 5 жыл бұрын
I work for a calibration company and calibration isn't just a pass or fail testing its more of a test to see if your instrument is reading to the manufacturer's specification. We provide a certificate with all the test results so the user can account for error in their measurements. We also optimize/adjust the equipment if it looks like it is drifting to the edge or outside of its stated tolerance.
@risvegliato
@risvegliato 5 жыл бұрын
Quite right! I actually work for the cal lab that stuck that red reject label on that Robin tester (Quasartronics), and you would get a full cert with tolerances and uncertainties, not just pass/fail.
@amorphuc
@amorphuc Жыл бұрын
I finally got a Uni-T 210E ($50.00) after seeing yours after you got it a while back. I really went through some "gosh, do I really need this" sorts of thoughts but went for it. I really like it, mostly for the DC clamp function. I still use this Aneng AN8002 ($13.00) for most stuff which I got originally because it could measure capacitance. I thought I was having problems with my home AC unit. It's interesting, like you've done here, to just compare the two. Just now, I'm finding the Cap test pretty much spot on between the two for a couple beefy AC caps. A 35 + 5 uf 440 / 370 VAC one and a 145 uf 330 VAC one. Now I'm curious to make a little box like you have for testing resistance.
@2lefThumbs
@2lefThumbs 5 жыл бұрын
Don't forget to repeat this during a harsh Manx winter when your hands are tingeing blue 👍👍
@gamerpaddy
@gamerpaddy 5 жыл бұрын
U can Hack the ut210e eeprom to get DC as Default current measure. Adjust Backlight duration and increase counts from 2000 to like 8000 or Higher. And some more Features
@antoineroquentin2297
@antoineroquentin2297 5 жыл бұрын
good enough for 'stralia
@Magnetic_Spaceman
@Magnetic_Spaceman 5 жыл бұрын
Standard bullet crimp connectors can be used in a pinch for custom leads on those cheap meters.
@nigozeroichi2501
@nigozeroichi2501 3 жыл бұрын
I have a PSA, if anyone has a multi meter or clamp meter and it develops a rattle, stop using it immediately! I have a Klein clamp meter that I use routinely on 480v. After a job I noticed my meter had developed a small rattle, I thought that I must have dropped it and a bit of plastic had broke inside, yesterday I had to put fresh batteries in it and decided to investigate the rattle, my blood went cold when a star washer and nut dropped out of the meter body, the nut and washer were off the negative lead terminal that connects to the bulkhead connector, and the positive was loose😱 I had been in a tiny room installing a 480V - 208V 15kva transformer😰 from now on screw the warranty all new meters I buy are getting opened and inspected by me before going into service and getting double nutted and thread locker, I think my grandfather must have been watching over me that day (started as a lineman and went to school and became an electrical engineer) I think they should have meters with clear cases for visual inspections, I don't want my hand blown off because some A-hole didn't tighten the nuts in my meter.
@InssiAjaton
@InssiAjaton 5 жыл бұрын
When you get jittery resistance readings, in my experience the problem often is that the test leads have experienced too many bends next to the probe end or the banana plug end. There are just a few strands left, while the bulk of them are broken and may or may not touch for contact. In a couple of cases I found that the soldering of the banana jack to the printed circuit board had been stressed too much and had failed.. As the sockets tend to be nickel plated, it was a pain to fix the solder connections, but with good flux and avoiding too much heat on the PCB did the trick and both the meters still work fine.
@simonhopkins3867
@simonhopkins3867 5 жыл бұрын
Cool I was just about to ask you about V and I references I look forward to it. Thanks bud. 😊
@uK8cvPAq
@uK8cvPAq 5 жыл бұрын
I used to think calibration was performed in a high tech lab by people in white coats with the mission impossible theme playing in the background.
@tomcardale5596
@tomcardale5596 3 жыл бұрын
I was working somewhere last year that had sent their ruler off for calibration. Admittedly a 1m glass ruler with 1/10mm graduations, but I did wonder what the calibration place could do to adjust it!
@srduke
@srduke 5 жыл бұрын
"Time consuming". With your videos, that isn't a problem. Bring it on!
@davemoore5222
@davemoore5222 2 жыл бұрын
Big Clive. I understand your disdain for ‘calibration’, my life’s work until Covid struck. In the 70s and 80s a lot of the better meters (rarely got involved with 4 and 5 digit meters) had different guaranteed accuracies for 1, 2 and 5 years. Our work required that those meters would give the one year accuracy continuously. So in those days calibration did involve annual adjustments to ensure those early 6 and 7 digit meters would give the accuracy the job required. However, nowadays 7 and 8 digit meters give better accuracy measurements over 5 year periods than those older ones over one year. Thus people like me are no longer needed. Each year my salary can buy them a new meter plus an outsourced calibration of the old ones.
@bigclivedotcom
@bigclivedotcom 2 жыл бұрын
My disdain is for modern profit motivated calibration.
@scriptguru4669
@scriptguru4669 5 жыл бұрын
I'm a spark and never send my fluke/robin 1653 MFT for calibration, I just prove my meter against other meters that have "been calibrated" but the test rig you made is a good idea.
@electrogrim
@electrogrim 5 жыл бұрын
Would have been good to include some analogue meters for comparison, maybe an AVO 8? I made a small 3 decade box using 1% resistors, as a rough test box but mostly as a fast way to tweak LED resistor values for brightness. Use the calculated value as a starting point then adjust the decade box (usually) up or down to taste
@thephilpott2194
@thephilpott2194 5 жыл бұрын
Certainly an Avo 8 should be invited to this party! (the Mk IV onwards are not built to last, but a Mk II or Mk III performs surprisingly well on resistance provided you: a) Don't stray too far into the extreme ends of the scale b) Run all 3 potentiometers through their full range and back before using them for zeroing. Julian's a bit scathing about old Avo's but Clive seems to have a soft spot for cobwebs....but is the workbench strong enough..!? Perhaps such exposure might save more old equipment from being made into tablelamps by blokes wearing their grandfather's corduroys and horn rimmed specs (minus the glass, of course..)
@TheManLab7
@TheManLab7 5 жыл бұрын
I'm only writing this to tell other people in the comments. All meters in the UK need to be sent off annually to be checked and validated (and yes, it's just a pass or fail). It's got nothing to do with Part P as it's far more important than when it comes to commercial and industrial e.g. hospitals, prisons, steel mills, paper mills, water treatment plants, recycling plants, date centers, etc. Meters were being sent off WAY before Part P. The company I did my apprenticeship with only used Megger and Fluke which they sent back to the manufacturer (that's including PAT). They also did the same with Lux meters as they needed to be sent off annually to be checked with a pass or fail certificate. If the company gets pissy about something n asks "what type of meter they used and when it was last calibrated" they'll just show the company what meters were used on that installation and as it's a reputable name brand which everyone knows (instead of something cheap n nasty), they'll be less likely to pick holes. Not that this has ever happened.
5 жыл бұрын
Funny, the little yellow meter that Clive tested near the end of the video, and cost me £5 is the only one I have. I have no way of testing its accuracy, but, then again I think the last time I used it was last year, so it's not exactly critical for me. But a good video as always, Clive.
@1marcelfilms
@1marcelfilms Жыл бұрын
i love my cheap meter. Having one in the garage is so much easier than having to go upstairs to get my "better" meter
@LiLi-or2gm
@LiLi-or2gm 5 жыл бұрын
You should test one of those cheap "component" testers- the kind that have the ZIF socket, an LCD screen, and a pushbutton, and that's it. I think I payed $15 for mine. It's pretty cool and seems to be pretty accurate. It analyzes semiconductors, caps, resistors, many ICs, inductors, and not sure what else, and does so automatically (it figures out what kind of component you've plugged into it). It displays a little pin diagram along with the pertinent values for the part. Makes sorting a pile of parts a cinch!
@albanana683
@albanana683 5 жыл бұрын
I just got one of these, amazing box of tricks. Surprisingly accurate once calibrated. Search for GM328 on eBay, you can get a kit or ready built. Clive should do the kit build and then test it.
@bigclivedotcom
@bigclivedotcom 5 жыл бұрын
Shamefully I've got a few different types of those testers and they rarely make an appearance. They're extraordinary in what they do and the accuracy. Not ultra accurate, but very acceptable. It's clear that geeks were involved in the epic software in them.
@AntonioClaudioMichael
@AntonioClaudioMichael 5 жыл бұрын
Great video Clive love the tester you made
@jeffflowers5489
@jeffflowers5489 5 жыл бұрын
A comment about the faulty Robin meter... I may be wrong (and I probably am) but some meters (mostly analog) use a AA battery for lower resistance scales and a 9v for higher resistance scales. Perhaps this has two batteries and one is dead.
@dashcamandy2242
@dashcamandy2242 5 жыл бұрын
I misplaced my two cheapie yellow meters, the not-quite-so-cheapie black meter I bought with the Cat5 tester has also gone MIA, and like you experienced, the leads to go crap. So a few days ago I went meter shopping at Walmart. The one model in Housewares was overpriced, so I strolled over to Automotive. They had two options, fairly close in price, under the EverStart brand (Walmart's store brand for car batteries). I ended up grabbing one that came with a thermocouple, a nice pumpkin-orange backlight, and I picked this one over the lower-priced unit because it includes the non-contact sensor. The leads insert well, click into place easily, and un-click just as easily. It's rated 300VAC, which is more than enough for my needs. Now, if I can just find a schematic for my Eico Cortina Sound n' Color color organ, so I can set about restoring it to its former 1970s glory...
@johnclavis
@johnclavis 5 жыл бұрын
LOL makes me feel old that I remember when hobbyist multimeters were mostly analog...
@K-o-R
@K-o-R 5 жыл бұрын
The cheapy ones are not great, but not terrible.
@paullelys161
@paullelys161 2 жыл бұрын
I also have the UNI-T and it's a great little meter which I've used many times with current clamp and a very old Fluke 8025B which can be calibrated at home although it was only very slightly out I assume due to it's regular calibration while it served in the RAAF. Fairly big and heavy grey thing but it's my every day use meter.
@PeterGrant
@PeterGrant 5 жыл бұрын
I had a meter that decided to start measuring voltage wrong - almost exactly half what it should have been, curiously. That was a half decent Maplin's own brand, currently just using the cheapie ones I have but been thinking about buying a Fluke as I now have enough cash to buy something more serious. But sounds like you might actually advise something else, despite the sort of 'No one ever got blamed for using a Fluke' attitude.
@noakeswalker
@noakeswalker 5 жыл бұрын
I am amazed that even the cheapy yellow meter was ok. The (much better) Uni-T 210E clamp meter has a fairly accurate capacitance range too - even down to pF - not as good as a dedicated LCR meter I'm sure, but mine gets pretty close to the truth :o)
@we-are-electric1445
@we-are-electric1445 Жыл бұрын
The high voltage resistance test is for insulation resistance. Meters used on mains appliances around the home should be CAT 2 rated at least. Measuring mains voltage on wiring directly requires a CAT 3 meter. Measuring at the consumer unit requires a CAT 4 meter. A lesser meter could literally catch fire in your hands. Cheap meters do not have the isolation to prevent arcing. The arcing is caused by voltage spikes on the incoming mains supply - these spikes typically in the KV range bridge the input by ionizing the air and can cause a meter not designed to protect against this to burst into flames. As for calibrating meters. This is essential for an electrician because he/she needs to know the resistance to 0.05 Ohms. Even a fraction of an Ohm can cause protective devices like circuit breakers to fail to operate within the disconnection times required by the wiring regulation ( BS 7671) - or to fail to operate at all leaving people susceptible to potentially lethal faults and also the possibility of a fire as excessive cable loading over to long a time period causes the cable insulation to melt and degrade. The reference to Part P scam is wide of the mark. Calibration tests include RCD performance and high fault current tests (to be sure fault current will trip a circuit breaker) along with the ability of the meter to determine loop impedance back to the substation (Ze) and the impedance of the cabling within the house (known as the R1+R2 test).
@bigclivedotcom
@bigclivedotcom Жыл бұрын
The R1 R2 test is very flawed. But congratulations on passing your part P.
@we-are-electric1445
@we-are-electric1445 Жыл бұрын
@@bigclivedotcom Degree in Electrical Engineering - 1985 but thanks for giving me the Pass on the Part P. How much is a certificate - I'll put it on the wall.😁 Anyone using any instrument to take measurements which if wrong could affect someone's life should make sure it is calibrated and the instrument is properly looked after and regularly tested (within the limits of practicability). I would say to anyone watching your videos (which I often find entertaining) if you have no supervised training or experience with mains electricity then leave it alone. Stick to 12 Volts. If you have a gripe about Part P (and it sounds like you have) then perhaps the solution is the NICEIC sticks to regulating electricians in industry where there are staff such as other electricians, electrical engineers etc to pick up faults and the rest of the electricians working in other sectors are overseen by the local council. A domestic electrician doesn't need the training of an electrician working in manufacturing. Having said that over the last 37 years I've come across plenty NICEIC registered electricians who couldn't do basic maths and repeatedly failed the latest wiring regulations exam. For every excellent NICEIC registered electrician out there you will find plenty not so good ones. Wiring systems designed and installed properly should perform adequately unless subsequently altered by person(s) who don't know what they are doing. .
@bigclivedotcom
@bigclivedotcom Жыл бұрын
@@we-are-electric1445 I do have a huge problem with a private marketing company that falsely presents itself as an electrical authority, used the death of someone to further their agenda and have deskilled the electrical industry to a one week slideshow.
@we-are-electric1445
@we-are-electric1445 Жыл бұрын
@@bigclivedotcom As I understand it the rules for NICEIC have now changed .. It is primarily the domestic side of things which has caused the problem no doubt precipitated by the building industry pushing for domestic installer schemes rather than a full term apprentice. Domestic installers though don't work in industry - or at least they shouldn't. There should be qualified electricians and engineers in industry to supervise unqualified people - that has how the system has always been. I have come across some domestic installers who were pretty good at what they do - they may have come from an engineering background not simply from stacking shelves at the local supermarket. If the NIC has a role then it should be industrial where there usually are people to check work anyway . If you know someone else's work is potentially dangerous you are not going to leave it. Everything else should be overseen by the local council. A system where a private electrician puts forward one job of his or her choice for assessment each year out of possibly hundreds is madness. At the very least they should be checked at random. If you feel passionately about standards (and it seems you do ) then you have enough subscribers to open a debate. Don't complain about the system - try and do something about it. The big problem with domestic work is people doing work on their own properties - that ought to be illegal. The NIC or any other electricians body can't stop that - that's a job for Parliament.
@monkeyman2174
@monkeyman2174 5 жыл бұрын
I am a Metrologist and I do calibration. It is not a yes no thing if you send it to a proper facility in the USA. We calibrate adjust and repair. You must be dealing with a government.
@acmefixer1
@acmefixer1 5 жыл бұрын
Monkey Man Often the meters have parts that are laser trimmed before they are encapsulated. I can't see how you could repair or calibrate the part - it would have to be replaced. But manufacturers don't have the parts or the parts cost as much or more than the meter so it's usually cheaper to replace the whole meter. 😦
@monkeyman2174
@monkeyman2174 5 жыл бұрын
@@acmefixer1 We do it all the time.
@Gigator
@Gigator 5 жыл бұрын
That's just two different things. One is validation that everything works correctly and one is calibration and repair. Closest thing I can compare it to is that in Germany, we have the car "Hauptuntersuchung" done by TÜV or Dekra (so generally called "TÜV"). There, the expert tests a set list of things (breaks, oil, wear, tires etc.). If they are in spec, you pass. If not, you have 2 weeks to get them done and retest. If you "fail" you go to your car repair guy with that list and he works on those flaws (if it is still economical). Then you go to TÜV and get your stamp. For lab and other equipment (scale, power meter, gas pump...), the German term would be "Eichung". "Eichung" is the thing the government mandates. It requires certain parameters to get approved and has to be repeated every few years (thinking two). Things that are not mandated that way can and should still be calibrated which has to be documented.
@bigclivedotcom
@bigclivedotcom 5 жыл бұрын
We're dealing with a protection racket. A private company that duped people into believing it was a government body and that anybody who does home wiring should pay them cash.
How to use your trashy meter without blowing it up (much)
23:12
bigclivedotcom
Рет қаралды 231 М.
From Small To Giant Pop Corn #katebrush #funny #shorts
00:17
Kate Brush
Рет қаралды 72 МЛН
How Strong is Tin Foil? 💪
00:26
Preston
Рет қаралды 146 МЛН
Man Mocks Wife's Exercise Routine, Faces Embarrassment at Work #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 6 МЛН
Cheapest way to learn to solder
23:35
bigclivedotcom
Рет қаралды 126 М.
Inside some dodgy Chinese USB power supplies from Greece.
23:02
bigclivedotcom
Рет қаралды 381 М.
Inside a Zoll defibrillator - with SCARY capacitor
24:26
bigclivedotcom
Рет қаралды 129 М.
Fixing an ezOutlet with inappropriate components.
15:59
bigclivedotcom
Рет қаралды 143 М.
Designing the Centaur pinball replacement echo card.
20:05
bigclivedotcom
Рет қаралды 116 М.
Crystal Radios: No Batteries? No Problem!
25:06
Our Own Devices
Рет қаралды 274 М.
Let's build a voltage multiplier!
16:32
Ben Eater
Рет қаралды 2,1 МЛН
Thick, black ribbed overhead power lines.  Including ABC termination.
20:09
Test of the Yihua 502D USB bench power supply.  (With fix!)
24:00
bigclivedotcom
Рет қаралды 216 М.
How to Make a Shunt Current Sense Resistor
11:17
ElectroBOOM
Рет қаралды 2,3 МЛН
From Small To Giant Pop Corn #katebrush #funny #shorts
00:17
Kate Brush
Рет қаралды 72 МЛН