That is one amazing device didn't expect to see a first degree heart block on ecg though
@petea19183 жыл бұрын
Just bought this but mine also has the Glucose Meter. After ECG hand reading i have a ECG reading of ‘Irregular heart beat’. I can now keep my eye closely on this. I’m 56 years of age and taking high blood pressure medication, Statins and medication for Ulcerative Colitis.
@francoismorgan3 жыл бұрын
Did you ever check if the QTc matches one from a professional grade EKG machine? By the way, there is a second screen for EKG if using the leads (tap bottom of the screen), you can choose wrist placement or chest, may be why QTc was different.
@JoelWelter4 жыл бұрын
Well done. This technological improvement always amaze me, though I'm still waiting for my flying car. Damn you, Jetsons!
@brianwest27752 жыл бұрын
How did the EKG waveform compare? Less detail than the hospital monitor or ? No surprise that the heart rate is correct.
@helicart3 жыл бұрын
6:10 The nurse did not connect the electrodes as per the manual. She attached the red electrode as RA (sub/mid right clavicle) and the green electrode as LA (sub/mid left clavicle). This gives a Lead I vector. The manual indicates for a lead I vector, attach the electrodes to each wrist. However, where the nurse attached is acceptable if a Lead I vector is intended. However, the nurse indicated she wanted a Lead II vector, because that's what she selected on the monitor. This requires the red electrode be attached as LL. Specifically the manual says attach to the lower left abdomen. I suspect the nurse may have been confused by the fact the electrodes are colored by IEC convention, not AHA (American). i.e. IEC : RA= red ; LL= green The manufacturer is a Chinese company. The nurse was otherwise all over that monitor, and had obviously played with it a lot. However, I rarely meet a nurse who comprehends EKG theory and practise fundamentals......nor a doctor.
@3ormore8874 жыл бұрын
Test the "Masimo Sleep" and "Masimo SafetyNet" next!
@DNadler10224 жыл бұрын
I was already looking at that unit because I’m on Tikosyn 500mcg bid, Toprol XL 100mg bid. I had previously been on the max dose of Flecainide 200mg bid and my QT interval was too wide, so I was switched to Tikosyn. My Electrophysiologist is checking it out. I just can’t afford the $500 price tag right now. The ECG model only is $120.
@johnm6866 Жыл бұрын
Wellue doesn't deliver to the U.S anymore. Where can you order this?
@yinyangdoc25794 жыл бұрын
Is she also having 1st degree av heart block i thing pr interval is prolonged too.
@scrimmo4 жыл бұрын
Lol
@yinyangdoc25794 жыл бұрын
@@scrimmo why?
@ChrisRRT3 жыл бұрын
It does look like a heart block. In my experience it is usually seen in older people kinda weird to se in a young person.
@germanmartinezcorral1384 жыл бұрын
Dr Mellick you are awesome
@lmellick4 жыл бұрын
Very kind of you!
@stephaniethelander9254 жыл бұрын
Another great, educational video. Thank you so much for posting these😊
@lmellick4 жыл бұрын
Thank you!!
@محسنحسینی-ن7ع11 ай бұрын
Hello, I have an icd device in my heart, can I use this device?
@محسنحسینی-ن7ع11 ай бұрын
Model unify assura 3361- 40c crt-d
@lmellick11 ай бұрын
There should be no problem.
@mehulgzw Жыл бұрын
Can this be used for babies
@sp-pz8uc3 жыл бұрын
After looking at hers, maybe I'm not about to flatline.
@jeffk77344 жыл бұрын
When watching your video I noticed some text to speech happening throughout the video. I wonder then how accessible this would be to someone who is blind. I am blind, and would be willing to test this out.
@ميدوتبت2 жыл бұрын
كم سعر هذا الجهاز
@phillight20084 жыл бұрын
She has a first degree AV block!
@ChrisRRT3 жыл бұрын
Yep. I am a RT and I at first didn't look to closely but now I see that. Seems a bit young for a AV block.
@muzikmon22672 жыл бұрын
YOU HOOKED UP THE ELECTRODES WRONG. It says right in the directions one of the electrodes goes to the top right hand collarbone fleshy side. The other electrode is supposed to go on the bottom left hand abdomen. You had them both up at the collarbone That's not the way it's supposed to be. Or you could have taken the electrodes and putting them on the inside of both rests left and right.. That's probably why you got a different QTc Did anyone read the directions lol
@InformaticageNJP2 жыл бұрын
It just records lead I instead or lead II, QTc would not significantly change.