Always trust Linus to do a Waterloop leak video once every few months. Consistency over a decade of videos, I love it.
@LethallyReptarded3 күн бұрын
Honestly what I was thinking when this came up 😂
@andrew18983 күн бұрын
He could save himself so much time by just making his rack into an aquarium rack and cool the mineral oil
@xb3ud3 күн бұрын
@@andrew1898 I've been waiting for LTT to do another mineral oil PC video for 10 years now.
@jacobgames34123 күн бұрын
Same thought
@iridium11183 күн бұрын
It's a sign of how unreliable they are.
@jsncrso3 күн бұрын
Seasoned marine electrical engineer here. We specialize in galvanic and electrolytic corrosion prevention. Galvanic corrosion is caused by DC, not AC. Isolation transformers are used to derive a separate ground to prevent DC eddy currents of 2V or under from destroying metals. You CANNOT connect the ground on either side of the isolation transformer, or it does absolutely nothing. I'm not sure what you bought, but most of those benchtop isolation transformers do not derive a separate ground. It seems counterintuitive, but the DC current will just travel though the ground and the isolation transformer would be completely useless. The excessive rack grounding wasn't really necessary either as normally these racks are already grounded through the chassis of the equipment in the rack (if in doubt, use a multimeter and ohm it out). If this fails, look up a marine galvanic isolator. This little $ 50 device would have completely taken care of the problem, but i supposed it would have made for a less interesting video lol. They work well, and these are installed on the shore power inlet on boats. The AC ground on a boat is also bonded to the DC- battery ground and the sacrificial anode (along with other bits of metal in the water). Add in some saltiness to the water with a few other boats in a marina with some faulty wiring, and you have a recipe for many thousands of dollars of damage to engines and anything else touching water. These galvanic idolators prevent that and are nothing but a couple of diodes in parallel (and opposite polarity) which will pass an AC fault current easily tripping a GFCI, ELCI, or main breaker while blocking the harmful DC eddy currents that are destructive. You can even make one yourself, but you will need diodes rated to the circuit ampacity which is dictated by the breaker size. Love your videos!
@DanielFSmith3 күн бұрын
I'd have preferred to see the rack units grounded at the (internal) fittings: the heat sink inside the box might not be bonded to the chassis.
@Mark-M723 күн бұрын
Shhh! if you tell him how to do it properly we wont see the next instalment . . . should be around mid December 🤞🤞
@BudgiePanic3 күн бұрын
@@Mark-M72wouldn’t want to end this series prematurely
@benjaminschimpf4213 күн бұрын
Nah. Just change out the flux capacitor.
@4crafters5973 күн бұрын
It's been a long time since Chemistry and Galvanics for me, but wouldn't the water need to be in contact with electric? Like two metals of different types might make a battery, yes, but only if their potential / the difference of them is high enough; so checking the compatibility should have prevented that. The other way would require electrodes, i.e. metals connected to voltage touching the water, no? Wouldn't it then be a way bigger problem that you have water, carrying hundreds of volts and amperes, ready to short/fry anything if it ever leaked? Also obviously this only works if the water contains ions, but i guess at enough of a difference in potential the main point is that any metal would shed ions?
@Cobinja3 күн бұрын
By now Jake should own a quarter of the house. He already built/rebuilt/repaired half of it.
@CriticalCipher3 күн бұрын
Damn my contractor should get the deed then
@TechProFury3 күн бұрын
Maybe if he did it for free...
@dollymix53 күн бұрын
Brother. Let's fight for the workers
@Senthiuz3 күн бұрын
Lol silly, it's vancouver, people under 50 can't own houses there.
@99mage993 күн бұрын
That's... not how paid labor works, but okay lmao.
@mattgeroski96413 күн бұрын
Industrial controls engineer here…. You should add some sort of electrically operated valves in the lines before the pumps. If you shutoff the pumps due to a leak, gravity may still allow flow through the pump
@hellboyz20122 күн бұрын
At this point they just need to put in a PLC lol
@LG_SmartFridge2 күн бұрын
Monkey here, can a brother borrow a banana?
@chrisdawes727014 сағат бұрын
and put some kind of draining system for when it happens again.
@chrisdawes727014 сағат бұрын
especially with a massive hot water tank on other side of room ;-) - needs to upgrade to continuous hot water... geez what kind of geek is he?
@chrisdawes727014 сағат бұрын
or have another sensor to activate a bilge pump to pump water outside if he can't get a drain on the floor...
@donkey12713 күн бұрын
4:51 editor missed a trick not adding Jake to the family lineup
@cameront85393 күн бұрын
Thanks LTT! I now know to use air cooling for everything.
@mike170322 күн бұрын
@@cameront8539 ya glad I watch these videos. I will never water cool anything. I don’t need “content” in my daily life.
@The_KeeperКүн бұрын
Yup. JaysTwoCents; Shows you why watercooling is awesome. LTT; Shows you why it really isn't.
@christopherwiley58593 күн бұрын
Nice! Recommendations: -set up a testing schedule for yourself. Protection systems that aren't tested won't work when the demand occurs. Failures are like a watched pot--won't boil if you're paying attention! -your shutdown of the pumps should be "latched". It really really shouldn't turn them back on when the leak sensor clears. You want someone to go and physically check on it and reset. This is fun. Can't wait 'til y'all just buy Jake a PLC and go full industrial.
@peterg.82453 күн бұрын
Ladder logic is dead simple and you know the equipment is reliable.
@ArensLive3 күн бұрын
These are great suggestions ngl! I'd say they should listen to them, but more leak videos is always a plus!
@MarcSherwood3 күн бұрын
That is not a comment - it is a life lesson.
@Katia4133 күн бұрын
110% the pump should require a reset before restarting. If the leak just dried up but the tank was still empty, that would be a really bad time. They really should get an Automation Direct PLC or something. Even used ControlLogix chasses are pretty cheap if you go with an L6 processor and an ENBT module.
@Sassi79973 күн бұрын
@@Katia413 A PLC seems a bit overkill but they should definitely add a restart button for when the leakage sensor triggers.
@shadenoah3 күн бұрын
On the powershell command: you should always force the command to shutdown, otherwise the computers can be stuck due to an app, and that's something you wouldn't want to happen in case of a disaster. What I always do when I have to script things like that is always declare everything. Usually, when I want to shutdown the computer/server immediately, I always do this: shutdown -s -f -t 0 That way, you -Shutdown, -Force -Timer 0, meaning that it'll force the shutdown command, ignoring other programs forcing them to close and do it immediately. You TECHNICALLY don't need the -f and -t together, but I always do it regardless.
@MikrySoft3 күн бұрын
I would also add -d xx:yy and -c "comment" options to leave a trace in the event viewer for the reason why the shutdown happened
@lee-annewalker34303 күн бұрын
that is a command prompt command, not powershell stop-computer is the powershell native command...
@DRSDavidSoft3 күн бұрын
Bingo, Jake used only the /s switch thus the default timer is a non-zero value and hence the message. If /t 0 was also added it would immediately take effect and /f is required to force Windows to close all running apps to shutdown.
@mercab38953 күн бұрын
"shutdown /p /f" also works, and does the same thing. Immediate shutdown with applications killed.
@uggima13 күн бұрын
Heh yeahhhhhh not shutting down because notepad is open and had one character written into it would not be good....
@Novous3 күн бұрын
It is SUPER IMPORTANT that all grounds end at the SAME PLACE. If one is much longer, or you have extenders/connectors or splits the resistance of the wires is different. That means the grounds are at different effective voltages. And thats where ground loops happen.
@LordPente3 күн бұрын
Actually in this particular case if you want to completely isolate two different circuits, you do NOT want both of them grounded because if they share a common ground they are be definition, not isolated.
@irspecialer2 күн бұрын
This is wrong. Grounds can have different lengths or splits as long as they’re in the same circuit. Ground is ground and there is not different effective voltages whatever that means. Ground is always ground anywhere in the same circuit.
@johhnyknoxville39482 күн бұрын
They didnt even strip the paint of the case on the grounding connection point. This is so unprofessional and it will fail again as it does nothing right now.
@The_KeeperКүн бұрын
@@johhnyknoxville3948 That *Really* depends on the paint. A lot of case paints are conductive, literally to prevent this issue. (could be an issue on the ones they painted themselves, though) However, the threads probably haven't got any paint on them after the first time a screw was screwed in anyway, so the paint on the outside of the case wouldn't even be a problem in the first place seeing as the connector is touching the screw directly. What I'm saying here is; Unbunch your panties. Its more than good enough for a non-industrial use-case like this, and while its "unprofessional" it does what it needs to do. So calm down your mammaries.
@johhnyknoxville394820 сағат бұрын
@@The_Keeper paints are not conductive what are you even on babbling about and no, the inside of the screw hole isnt enough as inodized parts are indized as a whole. Also this screwhole isnt intended for grounding so the connection between this panel and the rest is unknown and probably never existed. Lower your tone when you have never worked with industrial stuff kid.
@ShaswataPaul3 күн бұрын
3:29 Linus Sewing Tips
@dlib893 күн бұрын
"That might be the best thing you've ever done" "My kids are right there..." Linus is such sweetheart, I never had such type of compliments from my parents. 10/10 parenting
@mindrewinder2 күн бұрын
I think he ment it in a way that his kids shouldnt hear that Linus barely accomplished anything in life besides maybe mashing some potatoes while swinging his feet to the monster mash song
@sntslilhlpr6601Күн бұрын
He really is a good parent. Love him or hate him, every time he's talked about his kids or his parenting style on the WAN show I've always been super impressed. And we can even see the results now with vids like upgrading the gaming van. I understand why he doesn't want them on camera constantly but I'd love to see more.
@Haskellerz3 күн бұрын
"EK carefully considered" Best oxymoron there
@japanskakaratemuva53093 күн бұрын
Yeah, that 'minor' issue with some nickel plated parts.
@milktobo74183 күн бұрын
plated brass fittings lol - brass is a garbage base material and there is a reason its used outdoors only, where leaks dont matter. Leads me to think the fitting was over-torqued and cracked the plating.
@willwunsche69403 күн бұрын
What do you mean? EK execs seems to be good at carefully considering how to open up foreign bank accounts 😂 without reporting them to regulators/their debt collectors. At least according to Gamer's Nexus's latest hardware news
@schtormm3 күн бұрын
they "carefully considered" stuff in about the same way Fanatec carefully considered stuff
@Drazil1003 күн бұрын
"Dumbledore said calmly"
@xarioln3 күн бұрын
Well... now if i ever build a rack system i'm making sure any watercooled stuff has a drain shield of some sort so if it ever leaks water rolls around everything else
@deathtrooper20483 күн бұрын
How about just keep water away from electronics. LTT always gets water damage.
@zxqhyr3 күн бұрын
@@deathtrooper2048 "don’t avoid problems, learn how to solve them” and also watercooling is fun.
@neruneri3 күн бұрын
@@deathtrooper2048 In fairness, the cause of the problem in this situation could have happened to anyone. They literally got scammed by whoever they bought the plumbing valve from.
@D3nn1s3 күн бұрын
@@zxqhyr sure it can be fun but for my daily gaming pc im def keeping it air cooled after all ive seen. +cheaper +reliability +mainenance free +higher resale value (gpu) -maybe a couple degrees hotter Id make that tradeoff anyday since none of my components are throtteling anyways. Plus my mb gets better airflow too :)
@acidburner4203 күн бұрын
All it takes is a thin plastic shield with drains on the sides, kinda like a sunroof drain in a car.
@bartoszkazmierczak72493 күн бұрын
About the leak sensors... This is not a robust way to do it. When using active high sensor logic, like shown at 16:15 you are assuming that the only connection being made by the water will be between the sensor terminals. If the sensor is installed anywhere near a grounded piece of metal (like the rack itself) it is very likely, that the water will be touching that grounded part as well, so both sensor terminals will in fact be connected to mains earth. Depending on how the Pi is powered and how the other sensors are wired, the Pi ground may also be connected to mains earth. This means, that the sensor may not detect the leak, because the sense pin will be shorted by the water to ground. Even if right now the Pi supply is floating - i.e. the Pi is powered by an isolated, ungrounded power supply, you have to consider, that it's quite easy to ground it unintentionally, by connecting another sensor to the board that would be grounded, which would mean that you will not even be aware that your leak sensors may not trigger.
@dark88reaper783 күн бұрын
This type of corrosion is why Grounding Systems for Homes are no longer allowed through the copper piping (at least in Germany). Back in the days they would just use Water or gas pipes to be used as the ground. These days old homes get a ring ground and new homes get a foundation ground. To prevent corrosion on the piping system and to prevent voltage differences we have to run a 6mm² wire to all the pipes in one big loop in the basement and connect them to the ground System. This way the current will run through the wire and bring it all to one "voltage".
@NtGism3 күн бұрын
That explosion when Jake opened the switch at 16:10 had me in stitches. Well done editor
@BladeScraper3 күн бұрын
when he plugged the cord in too lol 22:20
@adlannizar60Күн бұрын
I love these little bad explosions editing 😂
@Julian-db4dx3 күн бұрын
the reason the leak sensor isnt reading exactly 0V while its dry is to be able to tell the difference between a zero singal and a broken sensor. Not as important in a home setup but in industry applications where alot of sensors are at work the risk of one breaking is so high that having any signal as 0V or 0mA isnt something that is done.
@GunniBusch13 күн бұрын
I would assume it is the iodine in the water you mentioned in the last video. Nickel gets oxidized to nickel ions (Ni → Ni²⁺ + 2e⁻), and iodine is reduced to iodide ions (I₂ + 2e⁻ → 2I⁻). So, the presence of iodine directly accelerates nickel corrosion.
@rar234243 күн бұрын
@@GunniBusch1 they have been known to use tap water instead of distilled so it makes sense
@bartoszrybinski293 күн бұрын
@@rar23424ironically distilled water is more corrosive than tap water
@antonisautos87043 күн бұрын
@mzamroni they use floride at least in the US for that. They probably use the same in Canada
@sir-gamesalot3 күн бұрын
For those wondering, when you have a power source that outputs a specific voltage at specific amps, it means that it can output that voltage, and it can supply current from 0 amps up to the rated amps. It doesn't mean that the power supply will force X volts and Y amps through you. The amount of amps supplied is determined by the resistance of the what is consuming the power. The higher the resistance, the lower the current, the lower the resistance the higher the current, up to the capacity of the power supply. When you short the outputs of a power source, you introduce a very tiny resistance between the output terminals and you should get a lot of current flowing. Good power supplies have protections against this situation to avoid things overheating, blowing up, catching on fire, etc. They do this by measuring the output current and turning off the power when the threshold value is reached, which is usually a bit above the rated capacity. Bad power supplies usually just blow up when they are shorted or the current draw is too high.
@20a10v3 күн бұрын
“Don’t try this at home” Linus: *tries literally everything at home”
@erickoerner16293 күн бұрын
Jake might have made the best explanation of why using a pull up resistor is necessary. I use mstp networks frequently and have struggled to understand the need for them and now I get it.
@SamuelCarrier923 күн бұрын
Actually it's the worst i've seen. This would have a been Perfect moment to explains ohm's law and do a quick current path analysis/schematic/animation. Just looks like someone who knew what it was about told him to do so, so he did but without understanding how it works.
@DanKaschel3 күн бұрын
@@SamuelCarrier92uh, nope it would not have. There's a right amount of time to spend on each step and that ain't it. They were already pushing it tbh so I'm glad people are getting value out of it.
@scaredyfish3 күн бұрын
I’m surprised that breakout board didn’t have PU/PD resistors, as that’s a pretty common requirement when hooking up sensors.
@sG126693 күн бұрын
@@SamuelCarrier92bruh i would’ve turned the video offl
@DreitTheDarkDragon3 күн бұрын
It's like adding weak spring to one end of string, so when it's not loaded, it's always in defined position, pulling it up :)
@oguzhanakdogan97873 күн бұрын
All these water-cooling videos remind me that going with an air-cooler was such a wise decision.
@DRSDavidSoft3 күн бұрын
That's true. In my opinion it's not even "water-cooling", more like "water-transfers-heat-to-somewhere-else-which-will-then-be-actually-cooled-by-air", so the water is only used to transfer the heat to the radiators which do the actual cooling by air 😁
@NPurvis76223 күн бұрын
Yeah, go back to an air cooled car. Weird comment for an exotic cooling video.
@christomas81913 күн бұрын
@@NPurvis7622 Comparing a PC to a car is laughable. You’re the one with the weird comment here bud.
@lignorof84753 күн бұрын
@@NPurvis7622 i like my air cooled car though
@T0TALLYAWESOMEGUY3 күн бұрын
And it kinda makes me regret getting an AIO liquid cooler for my most recent build. One day, I'm going to have a problem.
@PsychoKiller2503 күн бұрын
0:52 Linus is going to rectify high blood pressure? 🤔
@matt76623 күн бұрын
Rectumfry.....
@BlackwinghacksBlogspot3 күн бұрын
mmmfgh@@matt7662
@uzaautumus2 күн бұрын
@@matt7662 (totally unrelated) just watched LOTR: FOTR on APV I cried like a baby when Boromir died (don't laugh)
@DanielRezaie3 күн бұрын
18:00 As a curious guy, that QR code was calling my name... Bravo Editor, Bravo!
@TheBackyardChemist11 сағат бұрын
was it a rickroll?
@GermanElias-hd6lc3 күн бұрын
18:00 that qr code leading to ltt store has to be the funniest shit I've ever seen
@eynorey3 күн бұрын
LOL I was looking for this comment :D
@superscatman42363 күн бұрын
When I saw an uncensored QR code I had to go back. Then I saw it was sharper than the rest of the screen. My first thought was "this goes to the LTT store doesn't it." Glad to find out I was right lol.
@benstanfill3633 күн бұрын
@@superscatman4236I thought it was strange it wasn't censored.
@AdamVP3 күн бұрын
I was waiting to be rick rolled to be honest
@martonk3495Күн бұрын
@@superscatman4236 Same but my thought was either the LTT Store or Rick Roll
@D3nn1s3 күн бұрын
16:12 legit scared me
@Dlutheran3 күн бұрын
Same here 😅
@alexlowe20543 күн бұрын
I actually called it! 9:35I apparently was wrong about the loop corrosion, but I definitely called vendors lying about the metals in the parts. So, I'll call that a partial win.
@ph33lix3 күн бұрын
Regarding the computer signing out and shutting down in less that a minute at 19:55; instead of 'shutdown /s', try 'shutdown -t 00 -s'
@rooboy693 күн бұрын
One zero is fine
@arnaudthevenet38022 күн бұрын
Came here to say that. Otherwise it shuts down in 60s by default if my memory is correct
@Toastmaster_50003 күн бұрын
Honestly pretty solid sponsorship. Like a genuinely good use of the product, and didn't feel forced
@ERRORCODE6163 күн бұрын
This must have been made before the recent EK news. EK and "carefully consider" don't really belong in the same sentence now lololol.
@whomolgan3 күн бұрын
+1
@willwunsche69403 күн бұрын
EK top management carefully considers how to threaten and extort their employees and dodge government officials 😂
@Keiuran3 күн бұрын
It's not good to equate company leadership with company engineers. Engineers are often doing their job properly regardless of where they work.
@willwunsche69403 күн бұрын
@@Keiuran True to be fair. Most of the EK stuff falls on four top level management people at least according to Gamers Nexus. They never complained about the quality of products besides the CEO not owning up for a bad defect in one and instead extorting a small mom pop shop for fixing the broken products to sell
@cheeseisgreat243 күн бұрын
@@KeiuranAccurate. I work in a company that does both engineering analyses and legal strategy for injured people suing companies, and after many, many years of reviewing discovery I can confirm that 99% of the time the harebrained ideas come from the bean counters in leadership, not the engineers.
@OrfFpv3 күн бұрын
this intro from the "pee myself" to the intro music is too great 1:06
@speedwaynutt3 күн бұрын
*computer peed itself
@zsoltlajtos65273 күн бұрын
2:00 The screwhole in the middle on the right side does seem to be discolored. Probably not due to corrosion though, I'm sure Linus has checked everything thoroughly
@milance0123 күн бұрын
also one on the left side
@RRanun3 күн бұрын
Ye I noticed the left side before that.
@darkwaxer3 күн бұрын
Is there anyway you can 3D print or buy some acrylic sheeting and thin piping which can go between the computers and drain to the floor to catch any future leaks so they don’t wipe out multiple computers? Oh and on the red handled gate valve, they are really crappy. I was draining an expansion vessel on a calorifier two weeks ago and I had one of these not catch the thread and refuse to open back up, which effectively turned the water off for half of a factory that produces bearings for nuclear reactors. I managed to open the valve by fully turning closed the valve as hard as I could and then opening it as softly as possible; the noise the system made as water flushed back through was tremendous. Replace the gate valves with ball valves. Bung up the tank (Google plumbing bung) so no more coolant can go down the pipes and you won’t need to drain the tanks.
@draimomdpdr3 күн бұрын
Thats all so sick, what a time to be alive. Such good toys
@EFazy3 күн бұрын
Guys! The chassis of the servers ARE grounded via the electrical connector! Those small cables made because you need good electrical connection on every part of the rack, so for example: the doors, the side panels, the top stuff... Those should be connected to ground, because if something became live (a server chassis, a faulty cable) then the power will go to the ground, and not through you :) But if the door not connected properly with cable, and may or may not have good connection, then is the door get live somehow, you will be zapped!
@TooMuchMiddle3 күн бұрын
Hence why grounding and bonding are two separate things. I wish they would have explained it better, or at all.
@TheAkashicTraveller3 күн бұрын
Fun fact, that isolation transformer makes all that grounding pointless since it'll prevent the RCD/GFCI from working anyway. Linus should put an RCD/GFCI on the server side of the transformer and ensure it is bonded with those ground lines. Though I guess it will still help prevent the corrosion issue.
@efad32153 күн бұрын
@TheAkashicTraveller The server is plugged into wall power, it's the pump on the other end of the transformer. Also they plugged the transformer into the server UPS to keep water flowing when there's a power outage
@washellwash18023 күн бұрын
@@TheAkashicTraveller GFCI's aren't bonded to ground lines. They respond to a difference between live and neutral. Still a good idea to put one on the output of the transformer. The original RCD will work though. Transformer can't put more power out than what's going in.
@orangemonkeykiller2 күн бұрын
Guys, the wires are for equipotential bonding (to pull all floating voltages down to the same earth potential, important for electronics also steel structures and copper piping), not protected earth bonding (which is for an RCD/GFCI in case of an electrical fault).
@connordenney97133 күн бұрын
Just a quick PSA, galvanically isolating things via a 1:1 transformer is generally safe, but there is the possibility using one will prevent your GFCI protections from working properly. I am no expert in this field, but it is worth looking into before you get one.
@LeafBoye3 күн бұрын
If your not an expert why are you even giving electrical suggestions?
@SlyNine3 күн бұрын
@@LeafBoyeonly experts are allowed to know things.
@ZeOfflinemaker3 күн бұрын
It probably will prevent it from working (that is kind of the idea behind galvanic isolation) but you can also not short yourself or other stuff to ground. Though if you touch phase and neutral there pretty much is nothing to save you so the pump probably should be labeled "spicy" at least.
@jamiealeksic84283 күн бұрын
@@LeafBoye just because he isn't an expert in the field doesn't make his advice not accurate and in this case not having GFCI is kinda important to know
@WenirR3 күн бұрын
@@LeafBoyebecause other not experts showed on their video that they are using big ass anti gfci device?
@TheHighlyannoyed3 күн бұрын
Random suggestion for Jake, using CAT is damn handy as an "everything wire", but if you use a little pigtail/patch cable for your "custom end", and leave the RJ45 on the other side you can use dirt cheap Ethernet Couplers to connect it to an unmodified cable of whatever length is needed. Repeat at the other end, and you've got an easily repairable/replaceable/testable cable.
@DanKaschel3 күн бұрын
Good hack for signal wire, but don't do this for anything used for powering a device.
@DRSDavidSoft3 күн бұрын
@@DanKaschel Can be used to power stuff if the current is low enough like 100mA. PoE injectors/splitters are pretty useful for such a usecase too, you can use a step-up DC booster to convert your 5V/12V to like 24..48V for transmission, then on the other end use a step-down to transform it back to the desired voltage. Obviously this is most useful for long wire runs, but a standard CAT5e cable is great for transmitting data (RS-485/RS-422) and power together, to like another building floor, the yard, etc.
@Atlessa3 күн бұрын
I love this hack, will deploy it in a project of my own.
@DanKaschel3 күн бұрын
@@DRSDavidSoft yeah, low amp stuff is fine. I just mean you can't use cheap Ethernet couplers to transmit 24V power and not expect your house to eventually burn down.
@DRSDavidSoft2 күн бұрын
@@DanKaschel Yes, exactly, it's meant as a data transmission cable.
@spaznos20002 күн бұрын
Whenever I feel bad about my self, I come here and watch you guys do stuff totally wrong most all the time and it makes me feel better.
@JimmyDali3 күн бұрын
8:45 Jake contaminates pump. 💀
@mike170323 күн бұрын
Couldn’t you put a solid metal “drain pan” or something between each thing on the rack? So if one leaks it won’t rain down on the stuff below it?
@bummer77363 күн бұрын
yeah i was thinking of that too. good idea.
@whykuable3 күн бұрын
Might mess with air flow and heating.
@hdgamerJonas3 күн бұрын
@@whykuable Airflow? For Computers in a Water Cooled Rack?
@mariueg3 күн бұрын
@@whykuable Airflow in racks is usually from front to back
@RaineyPeng3 күн бұрын
Yeah the tolerances between each unit of the rack probably isn’t enough, and using a whole 1u of space in between each server would not work
@Centomila3 күн бұрын
@10:15 Jake makes his own Valve. HL3 confirmed.
@elone39972 күн бұрын
There can be no doubt on this one...👍
@lukasustarsic17893 күн бұрын
Linus. Rack will be grounded over your UPS. AS long as UPS is grounded using the 3rd wire in the power grid and it is touching the rack metal on metal it will ground the rack as well.
@DrowslayerQC3 күн бұрын
I was wondering, the rack seemed to have a finish on it, it's not on bare metal. Is the finish conductive?
@yerdude3 күн бұрын
@@DrowslayerQC Their whole rack grounding seemed funnily unnecessary tbh, must've been jake's idea.
@johnscaramis25153 күн бұрын
@@DrowslayerQC The only reasonable answer is: you never know, therefore you assume the worst.
@Nick-Lab3 күн бұрын
"Well make sure you get it on camera" Now that is a boss lol
@DontBeMadBroКүн бұрын
What i like about these videos is unprofessional professionalism. He is playing, sitting on the ground, making jokes, it looks like two friends fixing the problem they have created. All the best guys
@JoshCP5273 күн бұрын
Just a note the water sensors that work off conductivity wont work with ro water or pure water. You run into this when the local water is garbage and the only way to clean it up is with ro and then you have to condition it after to reintroduce a set amount of minerals. Floats work in any. Also RO water will leach even stainless steel and corrode it over time.... Just from working with steamers and what not for work in the past.
@psy_harkn51003 күн бұрын
23:48 M539 Resturation.....in my Town
@ThreepwoodFanКүн бұрын
@@psy_harkn5100 ??
@jackrecher44083 күн бұрын
I work for a semiconductor brush manufacturer, all tubing/fittings (compression fit) we use for our process is teflon and we flush system with DI water in order to maintain a extremely low particle count. This also helps prevent corrosion and keeps our equipment extremely clean. The only downside is the cost.
@cooper101823 күн бұрын
Next video idea: Linus gets a distiller to make distilled water for his custom server loop.
@4RILDIGITAL2 күн бұрын
I'm really impressed with your meticulous approach to diagnosing and handling the problem. Using isolation transformers to prevent galvanic corrosion is brilliant.
@OffMeta-Gaming3 күн бұрын
I really hate I jumped from the " explosion ". 😅 I genuinely didn't expect it
@realzakariax3 күн бұрын
One thing I would maybe keep in mind is the leak sensor might lose connection to the leak when the water is stopped after a few moments and that could turn it back on causing more water then the leak would be detected, you get the point. Might be a good idea to either manually turn the water back on or put a delay of at least a minute for false positives to turn back on automatically
@Neuzahnstein3 күн бұрын
IEC 60364 cries loud here in special in 7:14 should be everything written in IEC 60364-5-54 (Low-voltage electrical installations - Selection and erection of electrical equipment - Earthing arrangements and protective conductors)
@alexscarbro7963 күн бұрын
How about using two flow sensors. One monitoring the flow to the rack and one measuring the return from the rack. If you then subtract the two readings (with a little filtering), you could be able to detect a slower leak. Another possibility is to monitor the fill state of the header tank. If it starts dropping, you’re losing water.
@meneldal3 күн бұрын
How precise are the sensors though? It's not uncommon to have something that is a few percent off and that would definitely make estimating a leak pretty difficult (unless it's quite massive).
@patrick_test1232 күн бұрын
@@meneldal If the other method is to wait for a puddle at the bottom of the rack you should be able to find a sensor that can do better than that.
@meneldalКүн бұрын
@@patrick_test123 I think measuring the amount of water in the tank should be good enough, and they're doing that with the floaters. You'll know when water goes missing.
@HGGdragon3 күн бұрын
Took me over half the video to realize that "leak" was referring to the actual *water leak* and not a product which informations were unintentionally dropped. >.
@chevystraightpipe17623 күн бұрын
Thank you Jake for showing me Sequent Microsystem. I saved their website and may use them for prototyping for work.
@geron00413 күн бұрын
Galvanic corossion, galvanic isolation are cool and all but what about galvanic square steel?
@noahluppe3 күн бұрын
eco friendly wood veneer is electrically isolating, might be worth considering
@robertgast59533 күн бұрын
galvanized square steel tubes ftw
@headcase22263 күн бұрын
Missed opportunity for the perfect segway 12:55
@benmol_3 күн бұрын
I worked with pretty powerful water-cooled lasers mounted inside racks. We always add a tray below them, either to contain or at least divert any leakage from the rest of the system (computers, data acquisition hardware, ups...)
@111smd3 күн бұрын
in a pc rack you would need to add another U height for each server to do this i am not saying it is impossible but it depends on how many U's you have and how many you are using
@benmol_3 күн бұрын
@@111smd exactly, but in practice new racks for often have some spare room. And if your tolerance are not too tight it is possible to shift elements by 1/3 U for a low profile tray
@hassnainvj3 күн бұрын
Moral of the 10 years of "Linux Leaks " story is "Air Cool your system".
@DanielKennedyaeos3 күн бұрын
Never had a leak, other than one really slow one I caught before it spilled a drop, in 20+ years of water-cooling PC's.
@Chimney_Swift3 күн бұрын
Another suggestion is to get a switched rack PDU (if you don't already have one). This would allow you to physically disconnect power to systems in case of a leak, which is obviously safer than just switching them off.
@loanqypol67973 күн бұрын
18:01 love the QR code for ltt store
@TheEclipsedLock3 күн бұрын
I can't believe I got jumpscared by explosions twice lol. It really does feel like that when working with electronics and wiring and all lol
@eynorey3 күн бұрын
saaaaaame
@SlevinKalevera3 күн бұрын
"Wrap it before you tap it" SENT me 🤣🤣🤣
@scagmo_au3 күн бұрын
5:54 I think Yvonne is a pretty grounded person
@Fluoressence3 күн бұрын
2:01 "the threading for all of the those screws is completely clean" As the video shows rust in the thread of the screw on the left.... lmao
@rafd973 күн бұрын
Jake missing the '/t 0' in the shutdown command weirdly upsets me Lol it was a great video though
@DRSDavidSoft3 күн бұрын
Yeah me too! I guess Jake isn't much of a Windows person, mostly working with *nixes.
@James22103 күн бұрын
Should have called it "Addressing the huge LTT leak"
@louispenn92533 күн бұрын
Have a low flow rate warning. Sometimes the impellers in flow sensors get gunked up and record lower flows. In some flow sensors you can remove the impeller to clean them, though it does void the warranty and you'd hope it would remain clean throughout the loop
@eric49033 күн бұрын
They did put a filter in place to prevent the turbine flowmeter from being gummed up. Still, mag flow meters can be had pretty cheap now, which I prefer because mechanical parts will fail.
@trbdann23 күн бұрын
does the command NEED to be sarcastic ? 19:27
@tweaker19683 күн бұрын
The Solution to an over-complicated problem is make it more complicated.... BRILLIANT!
@nedosos3 күн бұрын
In a pool of water stand a server rack. On its side, these words appear: My name is Linus, King of Tech; Look on my cooling, ye Nerdy, and despair!
@raafmaat3 күн бұрын
i love that he actually immediatly states that us viewers helped diagnose the problem :)
@AnimeMangaBazinga3 күн бұрын
Linus and Jake, Zooz makes a Valve control unit that can shut the valve when a command is sent to them. You should check it out. Also, FYI about Z-Wave, it can only send a signal at most 4 hops, so be careful about that with his Z-Wave network.
@LeafBoye3 күн бұрын
God I love KZbin comment experts
@AnimeMangaBazinga3 күн бұрын
@LeafBoye I have had this happen to me, and discovered that fact when trying to solve my own problem with my Z-Wave network. You can look it up yourself if you want to, I am happy to be given newer, accurate info if I am wrong.
@ArsStarhawk3 күн бұрын
I thought Linus said he was going to just ban people who make useless comments?
@taukakao2 күн бұрын
22:46 I want to clarify a common misunderstanding here: The current is determined by the voltage and the resistance, so the important part is the voltage, but that's not the whole story. Usually, you wouldn't notice 5V through skin, but since your tongue is wet it conducts electricity much better. Thus, the resistance of your tongue is much smaller so you have quite a bit higher current. Now when he says that he licked a 9V battery before doesn't necessarily mean he actually licked 9V. Batteries have an internal resistance so if you lick them, they won't output the full 9V. Licking something that is plugged into the wall is much more dangerous since the internal resistance is usually much much lower here, so you will most likely get the full voltage. So is licking something with 5V that is plugged into an outlet dangerous? Probably not, but I wouldn't recommend it. Especially because there could be a hardware fault which delivers over 100V directly into your tongue.
@tuurekeranen17713 күн бұрын
"Never watercool anything" is my main takeaway from this journey of issues. I am loving the concept and enjoy the content, but boy golly my comps will be air cooled and that is that.
@Zyrchin3 күн бұрын
This is the best series LLT has had since Sketchy Heat Sinks. Even my wife loved SHS, and she's an Communications Teacher.
@Shocker993 күн бұрын
7:00 Electricians looking at this in absolute horror! If/when the house gets electrically safety tested; it will fail due what is shown here.
@dekkonot3 күн бұрын
Yeah presumably it will be replaced by a real electrician in a few weeks. Or it won't be and they're showing the most realistic form of home improvement: a jank solution that becomes permanent lmao
@1BigBen3 күн бұрын
this is shown to trigger Electricians as they and rest of the professionals are almost as bad as fanboys in the comment section and they will feed the youtube algorithm.
@Gramen5423 күн бұрын
Don't forget the statement right after this... "its just a ground, it should be fine" , my boss would make a whip from ground wires and whip me out of consciousness if I ever say that.
@colbster123023 күн бұрын
The color match between Linus's and Jake's hair right now is insanely suspicious. basically admitted it at 5:38. Linus is Jakes dad
@itunesben1193 күн бұрын
They didnt show jake unplugging the relay from mains and I was just waiting for him to get zapped...glad they showed him plugging it back in. haha
@a11aaa11a2 күн бұрын
Oh you could totally use a poe esp32 with esphome for the leak sensors, I'm surprised this wasn't the first option! Much less to go wrong than a full rpi OS
@DamienGGW3 күн бұрын
16:11 why did that get me 😂
@rpfour43 күн бұрын
Not sure why you went with water cooling for your server considering a lot of the videos I've watched from you mentioned that air cooled is more reliable and accessible. If you really wanted to make use of your pool, you could have gone with water sourced heat pump and cooled the entire room. Or ducted it only to your server rack. Still would have made a great video.
@Knoppersd3 күн бұрын
@LTT nice idea with the water sensor, just beware that it might no work with demineralized water as the conductivity is lower. That is if demineralized water is used. What could also be done is add 2 Flow meters in the loop before and after the rack and compare for difference in flow with a margin of error. If there is it would indicate a leak.
@subynut3 күн бұрын
That's right! I completely forgot about that! Water in of itself is non-conductive. It's the minerals in the water that makes it conductive!
@turtlefrog3693 күн бұрын
the sensor reads very low conductivity. (even the air as it read 0.1)
@SamuelCarrier923 күн бұрын
I'm guessing a differential pressure transducer would do the job even more easily that measuring differential flow with 2 sensors.
@Knoppersd3 күн бұрын
@@SamuelCarrier92 would agree in a closed loop in an open loop system the pressure (which is resistance against flow) will be almost none in the return line and probably instable in the feed line. I am not entirely sure how the system is built but from what I gathered it is open loop. The flow stays constant no matter the pressure in a liquid.
@vooooooooooooo3 күн бұрын
I think jake poured demineralised water over sensor and read 0.5V only, so it still reads something.
@TinchoX3 күн бұрын
16:03 lmao good one😂 22:19 never gets old! Impressive work by the way... Let's hope nothing goes wrong~ 🎉
@thombaz2 күн бұрын
You can messure the in and out line and maybe can detect a leak if there is a big difference between the two.
@SSYoung1253 күн бұрын
Okay let's see if I understand this; The reason that the corrosion happened is because the rack was not properly grounded which means the rack was using the water in the loop as a ground and since there was a electronic differential in the rack versus ground then it caused the electronic galvanic corrosion. Correct? Or at least correct on a basic level?
@Krauerking3 күн бұрын
@@SSYoung125 I mean that's correct to what they thought it was until they found out the faucet head to the resevoir tank was made out of cheap metal and not 100% brass like they thought and was causing the corrosion. Oh and not from not being grounded persay but just not isolated so using the water to carry a very small electric differential.
@blargblarghonk3 күн бұрын
Pretty much. I've literally touched fittings on cars for heater hoses that just crumble in my hand from a bad engine ground.
@SamuelCarrier923 күн бұрын
I would say wrong. I would have loved to have them measure the resistance between rack and the ground of the house for them to realized it was 0 ohm. With that amount of grounded box in a rack directly touching metal to metal and screwed in making a good ground connection. So rack was as grounde as it is after adding the grounds. unless there was something isolating the cases for example pc cases were all plastic and that the scree weren't metal the you could have a ungrounded rack ( and it wouldn't matter). The ground not making a difference in my opinion I would agree with you that this video misses an electrical drawing or visual that explains what their theory is with regards to the voltage difference on the 2 parts of the system. how would on pump being fed at 120V and the pc being at 118V how would that affect corrosion? through induction? I'm not sure I understand their theory after that video.
@blargblarghonk3 күн бұрын
@@SamuelCarrier92 Water does weird things when energized even the slightest. Having an inconsistent ground doesn't help. I personally think it partly has to do with a mixture of issues like the ground issue and voltage generated from moving water in plastic pipe and mixture of metal.
@washellwash18023 күн бұрын
@@SamuelCarrier92 A rack standing on the ground does not mean it's grounded, tying it into the panel is a good move. As for the cases and the rack being the same potential, probably, though paint can be a bitch. But then again, it doesn't seem like they removed/scratched the paint for the grounding wires either.
@terok853 күн бұрын
Do not use multimeter to check that the voltage is zero. It can give you false reading. Use special tools like Fluke T110 voltage tester which has resistor to drain any residue voltages and gives proper reading.
@LRon-Hoyabembe3 күн бұрын
Lmfao, understanding how electricity works and you'll quickly learn how silly your statement is.
@Shiro_Amada3 күн бұрын
Should have the water looped racks vertical that way if one leaks it doesnt drench the racks below it.
@Slipsnek3 күн бұрын
how does bro have a tech disaster every 5 SECONDS 💀
@josefbry2 күн бұрын
Hi Jake - Sebastian- @Linus Tech Tips. Regarding the moisture sensor, I recommend implementing a rule that after an alarm is triggered, the pumps should not be activated automatically but only manually. The reason is simple - water might either soak into the ground or flow by gravity into a lower area, which could cause an incorrect system activation. Therefore, in case water is detected, it would be appropriate to automatically shut off the pumps and computers, and potentially close the valves - I suggest using electronic valves to prevent issues like gravity-fed drainage and unwanted circulation that might be caused by it. Manual activation of the pumps should be implemented as a necessary step to ensure that someone, like Sebastian, physically inspects the situation to determine whether it's a false alarm or a real issue. This approach would minimize unnecessary interventions while increasing the system’s safety and reliability.
@user-fq8zz8wj5y3 күн бұрын
You know what makes me mad when they say they're going to do it the right way in the future, but you know they're never going to do it until something else catastrophic happens
@htpc002Weirdhouse3 күн бұрын
It's called "content".
@99performancegarage3 күн бұрын
23:39 Nice M539 t-shirt!
@GeekyGamer1673 күн бұрын
Came here to say exactly this!! Love seeing his merch in the wild, every time I see someone wearing it I get very excited
@elbardo_lux3 күн бұрын
this could have been a colab with electroboom :(
@fuzzyhair3213 күн бұрын
i was actually expecting something to spark @16:00
@thomasrivard97723 күн бұрын
@@fuzzyhair321 electroboom ptsd
@DantalionNl3 күн бұрын
You can say a lot about LTT but they have a lot of attention for seemingly innocuous details. I appreciate using regular explosion animations as opposed to the typical youtube abom one you see everywhere. Few youtube channels understand that can be quite confronting.
@lifeHacker423 күн бұрын
Don't you use distilled water in your loops? I would have thought that would prevent that first sensor from working as pure water doesn't conduct electricity?
@the_undead3 күн бұрын
There is iodine in that water to try and keep bacteria growth to an absolute minimum, I don't know how conductive iodine is. Also, even though water is a pretty good insulator over that short of a distance, something could probably get through (probably about what they showed in the video) but for most applications, that kind of voltage drop is completely unacceptable, so it's effectively an insulator
@Mira-bt3zx3 күн бұрын
Even distilled water in a closed system will pick up contaminants over time. And especially if it’s dripping out of a corroded fitting over a bunch of computers, it will pick up dust and some oils before it gets to the sensor.
@DonellyBacchus3 күн бұрын
Does the water in water loops get slightly energized when running through all these pumps and through all these components? Like does the water pick up extraction electrons? Making your loop an electrolysis machine?
@wobblysauce3 күн бұрын
Yes, the voltage differential between the circuits. But this video was a shotgun approach to fixing the issues rather than identifying the problems, though there were a few.
@EpicBunty3 күн бұрын
I have heard that it picks up ions and becomes conductive over time or something like that.
@styyxofficial3 күн бұрын
@@wobblysaucejust curious, where does the voltage difference in the loop come from? There should be no wires in direct contact with the water right? For example, the water in the pumps would only be in contact with the interior of the pump, and none of the wires that run the motor?
@NotAnotherArtVideo3 күн бұрын
Did they bond the water (coolant) itself? I don't remember if they did that previously (or should in this case).
@WidgyAinz3 күн бұрын
I've never seen them try a mineral oil LOOP before, but it's messy and requires stronger pumps. It would only become conductive way down the line. The cheapest route is just regular water with some decent but cheap bio/fungi-cide and anti-corrosion additives that you super-regularly drain EVERYTHING out of and replace. Other than that, weighing distilled water or other methods to make it cheaper (including reverse osmosis system), and having yet another say, ZeroWater filter, just to ensure absolutely everything's out, then putting the bio/fungi-cide and anti-corrosion in. I'd maybe suggest running it back through filters once you drain it out of system, but unless you're going to either have a dedicated cheaper filter to filter out the crap like the biocide/anti-corrosion, or have nothing in the water and then have to do cleanse-and-rinse cycle(s)... You're better off figuring out tests for determining the conductivity of the water to a certain degree thats most practical for what you can realistically consistently clean it to, what the best cost-to-performance filters are, as well as water source, and then either A) figure out often you need to refilter or replace the water, or Ba)literally have the filter solutions be built into the loop or even have the main loop be Bb)switched like a train track to the filters that have quick disconnects going on (which allows these filters to be more easily checked for standards and swapped out, all without ever truly interrupting the performance, flow-rate, or uptime of the whole setup.
@Flash-FAFB3 күн бұрын
16:48 i wouldn't trust that sensor, if any voltage comes in contact with the water it will cause some electrolysis and that will make your parts rust even faster..
@mmmuck3 күн бұрын
I've never had a leak or damaged parts in over 20 years of builds. Good old air cooling and ventilation.
@illypsoillypso87613 күн бұрын
For the 5V tongue test, No mather how many Amps the power supply can give, 5V is 5v, so the amps that will flow is base on the resistance, in that case the tongue... The availlable Amps are irrelevant (unless if its lower than needed, voltage will drop) , the amps is the result of the volt and the resistance. Amps = Volt/resistance ex: 9V battery can deliver many amp, but are not dangerous. So a 5v power supply would not feel worst than testing a 9v battery on your tongue. 12v car battery can output hundreds of amps, but are not dangerous to touch with your hands because the resistance of you hands is too high so the amps will be low to the point you dont feel anything ( I would not try the tongue on those though ;) ) A simple visualisation would be to think of electricity as water, The volt would be the water pressure. the resistance(ohm) would be a restriction of the flow ( an almost closed valve or a small restrictive hose), the amps would be the amount of water that can get out (which depend on the pressure of the water and how much the flow is restricted), and the total availlable water before you ran out, would be the total capacity (mA\h), edit: error in the hand resistance phrase
@eduardschlegel93343 күн бұрын
* because the resistance of your hands is too high
@illypsoillypso87612 күн бұрын
@@eduardschlegel9334 thanks, I completly missed that, I change this sentence a couple of time and forgot to change the low to high after. I edited it
@meibensteiner3 күн бұрын
Did I miss something? Why did they use a Raspi and not an ESP32 with Esphome?
@k0ppit3 күн бұрын
Or use some proper equipment, like a Modbus TCP or Ethernet/IP Remote IO rack. Like Wago 750 or similar.
@pascha45273 күн бұрын
@@meibensteiner I believe as they explained in the video, it is so they can use an ethernet jack as Linus has wifi issues.
@meibensteiner3 күн бұрын
@@pascha4527 There are esp32 with ethernet. PoE even! I have one controlling a bunch of fans in my server cabinet. :D