The Vortex Flow Measuring Principle

  Рет қаралды 554,126

Endress+Hauser

Endress+Hauser

Күн бұрын

Пікірлер: 63
@clearshot798
@clearshot798 15 жыл бұрын
Someone finally described how a vortex meter works simply and effectively. Thank you!
@bladeslasher
@bladeslasher 6 жыл бұрын
Anyone else here because of Engineering Research Papers? Would definitely recommend buying meters from this company because they clearly know what they are doing and can explain it so easily.
@jobo9667
@jobo9667 6 жыл бұрын
I'm learning a lot from these videos...
@sasa51086
@sasa51086 5 жыл бұрын
So much information in a single advertisement!
@vimalzacharia2109
@vimalzacharia2109 4 жыл бұрын
beautifully illustrated
@KhairulIslam-iv2mh
@KhairulIslam-iv2mh 2 жыл бұрын
So knowledgeable video. Please make a tutorial for application of coriolis and vortex flow meter
@endresshauser
@endresshauser 2 жыл бұрын
Thank you for your comment. The following videos might be of use for you: Coriolis - kzbin.info/www/bejne/gpLHpIBjhdyYm7c - kzbin.info/www/bejne/kH7Qeqati9mlhZY - kzbin.info/www/bejne/qHiWoaxojpuig7c - kzbin.info/www/bejne/b5PHZ3mYeJekha8 Vortex - kzbin.info/www/bejne/pZ-7mZuXdtmgpZY - kzbin.info/www/bejne/raKTkomjrt2Gpsk - kzbin.info/www/bejne/iIfXoYF8oJp1htU - kzbin.info/www/bejne/i3K5Xmmvad10lac
@kornflakes3
@kornflakes3 13 жыл бұрын
Gracias por la explicacion, muy bien detallada. Thanks for the explanation, very well detailed.
@Yash_K999
@Yash_K999 6 жыл бұрын
Awesome video. Helped me a lot. Thank you Sir
@creativeeee
@creativeeee 4 жыл бұрын
nice and so informative video
@miguelangelmunoz4819
@miguelangelmunoz4819 9 жыл бұрын
very nice video a lot of information. Thank you.
@nazimyildiz2604
@nazimyildiz2604 10 жыл бұрын
Excellent. Great video
@paulneumann3280
@paulneumann3280 9 жыл бұрын
Wicked video- helps to understand for sure.
@FelipeNegron-c6s
@FelipeNegron-c6s 2 ай бұрын
The coop where I live decided to eliminate the thermostatic disks from our Dunham Bush steam traps and instead replace them with orifice plates. We have experienced higher annual steam costs after these replacements. I am an HVAC operating Engineer and have explained to the coop Board of replacement this error but it has fallen on deaf ears. Is there any source available to reinforce my opinion on the mistaken use of orifice plates in our steam traps?
@endresshauser
@endresshauser 2 ай бұрын
We have the following sources about steam and flowmeters dedicated to corresponding applications, but not specifically on orifice plates. Hopefully, the information helps you nonetheless: eh.digital/3Xm8UdQ eh.digital/3XaR8u4 eh.digital/4dRnHUU
@powersource8645
@powersource8645 24 күн бұрын
I have this flow meter, my sensor looks the same as the video but is stationary and not mechanically moving. Im confused.
@endresshauser
@endresshauser 21 күн бұрын
The movements of the sensor are very small and can’t be perceived by touch or sight. However, if your flowmeter does not measure correctly, please contact our service team for support www.endress.com/en/contact
@jaforikbal6388
@jaforikbal6388 Жыл бұрын
too good too good toooooooo goooooood
@huseyinfelek6449
@huseyinfelek6449 3 жыл бұрын
Thanks for the video. It must have been the outcome with long years of experience to have such a design, but I wonder why in most of the sensors, main body of sensor for the computations is far from the sensing body. I would appreciate any thoughts :)
@endresshauser
@endresshauser 3 жыл бұрын
Dear Hüseyin Felek, thank you for your comment. You are right, the measurement of the vortices should take place at the bluff body itself or directly downstream, which is the case in our products guaranteeing optimum performance.
@hamsaljroh7
@hamsaljroh7 13 жыл бұрын
nice explanation .. really i learn how it's work thanks..
@uthmanariff
@uthmanariff 5 жыл бұрын
Thank you sir for a helpful video. I love it !
@samiribrahimov1371
@samiribrahimov1371 6 ай бұрын
Vortex tipli sərfölçənlərin əsas iş prinsipi tezlik ölçmə metoduna əsaslanır. Maye sərfölçənə daxil olduqda metal sahəyə dəyir və burulma effekti yaradır. Bu burulğanlar sensorun sola və sağa hərəkət edərək tezlik yaranmasına səbəb olur. Tezlik axın sürəti ilə mütənasibdir.
@herrheitoco4087
@herrheitoco4087 11 жыл бұрын
Thank you for this description. They has helped me.
@snehalshelke1792
@snehalshelke1792 3 жыл бұрын
Do vortex flowmeters required 100% filled fluid in case of liquid flow measurement?
@endresshauser
@endresshauser 3 жыл бұрын
You are correct, vortex flowmeters require a fully filled pipe and a fully developed flow profile in order to measure. Please check the section Installation in the devices’ Technical Information, available on our website eh.digital/38OsR4E
@snehalshelke1792
@snehalshelke1792 3 жыл бұрын
@@endresshauser thank you ☺️!
@rishuverma575
@rishuverma575 7 жыл бұрын
the video was good ..plz upload more videos on flowmeter and if possible do so for level measurement​ too..
@endresshauser
@endresshauser 7 жыл бұрын
Thanks a lot! For more videos please see our playlists for flow (kzbin.info/aero/PLQRFGW1Z4TGHQosUE5__D8N5Vpq0rxKxG) and for level (kzbin.info/aero/PLQRFGW1Z4TGHsxqg5-ZzKblstj0PmZrGT) or have a look for to our total video offer: kzbin.infoplaylists
@skthriller394
@skthriller394 12 жыл бұрын
Nice video for learning
@ZsoltPinters
@ZsoltPinters 7 жыл бұрын
Awesome animation, thanks!
@safiyasaeed2851
@safiyasaeed2851 6 жыл бұрын
Thank you sir for a helpful video
@aamanullohimam1824
@aamanullohimam1824 7 жыл бұрын
very nice explanation, thank you.
@soumyamajumdar9932
@soumyamajumdar9932 5 жыл бұрын
This is an ad we shouldn't skip
@vishvanath6966
@vishvanath6966 6 жыл бұрын
Helpful. It will be more helpful if you includes where it can perform better such as corrosive fluids , chemical or steam lines
@mohieddinechouaibi4663
@mohieddinechouaibi4663 12 жыл бұрын
Thanks for the clear description.
@ajahemmanuelnwachukwu1659
@ajahemmanuelnwachukwu1659 4 жыл бұрын
Am indeed learning
@jitupanchal7122
@jitupanchal7122 Жыл бұрын
What is the main reasons of malfunctioning of sensor
@endresshauser
@endresshauser Жыл бұрын
The system is tested under severe conditions such as water hammering and overspeeding. From our experience, these out-of-specification events may result in a malfunction of the flowmeter in some cases despite the tests. In the case of difficult processes in your plant, we recommend to contact your point of sales for consultations regarding selection, sizing and installation www.endress.com/en/contact
@jamescool3424
@jamescool3424 6 жыл бұрын
Can you install a bypass line around the flow meter?
@endresshauser
@endresshauser 6 жыл бұрын
Yes, a bypass line with block valves around the flowmeter can be installed. This is even recommended (depending on the process) in case the flowmeter has to be dismounted from time to time for maintenance purposes.
@abaguila9
@abaguila9 13 жыл бұрын
que paso con las traducciones a diferentes idiomas, porque ya no funcionan...?
@manjeshb.c.6172
@manjeshb.c.6172 11 жыл бұрын
Thanks for the valuable info.
@flowmeters-tx
@flowmeters-tx 11 жыл бұрын
Loved it
@abdulkhadir18
@abdulkhadir18 9 жыл бұрын
thank you E&H ..this vedio s very informative
@محمودرفعت-ل2ف
@محمودرفعت-ل2ف 5 жыл бұрын
عظمة
@ariahmed5534
@ariahmed5534 3 жыл бұрын
Please how can i get the text of this vedio?
@konstantinkonyukhov2141
@konstantinkonyukhov2141 6 жыл бұрын
Vortices have cylindrical form?
@endresshauser
@endresshauser 6 жыл бұрын
As you can see in the movie as from time 1:43 the vortices are cylindrical over the whole diameter of the tube. This has to do with the barrier/bluff body in the flow tube which has a rectangular shape and creates the vortices along its edge.
@mmatss
@mmatss 8 жыл бұрын
1:09 is where its at.
@Bdub0317
@Bdub0317 10 жыл бұрын
outstanding
@intellectracoon
@intellectracoon 11 жыл бұрын
perfect just perfect thanx a lot
@maansinghchauhan8132
@maansinghchauhan8132 9 жыл бұрын
thanks boss for this
@정민영-q4k
@정민영-q4k 10 жыл бұрын
Thanks a lot
@osmangezmis7781
@osmangezmis7781 9 жыл бұрын
Thanksss
@pritesh55s
@pritesh55s 6 жыл бұрын
please enble Auto generated English caption
@chandramouli_997
@chandramouli_997 4 жыл бұрын
You explained so much science just to sell a product?
@ke4e2a72bs
@ke4e2a72bs 8 жыл бұрын
공정제어 화이팅~
@fabulous3482
@fabulous3482 2 жыл бұрын
Working principle based on ideal condition from what I get from this video. What are the ideal conditions. Constant flow? Clean flow? Laminar flow? etc etc. In real world application ideal conditions don't seem to exist mainly after several years in service. Can you explain when these meters do not read steam flow accurately. Does bend in the line changes flow reading? Does the meters has to be placed in straight run pipe? For me this video was not helpful at all.
@endresshauser
@endresshauser 2 жыл бұрын
Our Vortex flowmeters are designed for real life process conditions and have proven themselves in several hundred thousand applications in various industries for years. They can be used to measure the flow of liquids, gases and steam in extreme applications like hydrogen gas, liquid mercury, liquid bitumen and other applications where other measuring principles fail. A certain minimum flow rate is required for the vortices to form. In cases where the flow velocity is too low, this problem can be circumvented by installing a flowmeter with a reduced cross-section. This consequently increases the flow velocity and does not have any affect on the measuring accuracy. The inlet requirements can be found in the technical documentation for the device. If you have further questions, please get in touch with your local Endress+Hauser contact: www.endress.com/en/contact.
@NickMercurio
@NickMercurio 12 жыл бұрын
bluff body
@sarakhochonsaeng7742
@sarakhochonsaeng7742 4 жыл бұрын
อื่อหึ
@MomenulHasan
@MomenulHasan 10 жыл бұрын
Thanks for the clear description.
The Thermal Flow Measuring Principle
5:19
Endress+Hauser
Рет қаралды 238 М.
Introduction to Vortex Flow Meter Technology
4:50
Rosemount
Рет қаралды 226 М.
Lamborghini vs Smoke 😱
00:38
Topper Guild
Рет қаралды 51 МЛН
Steam quality measurement with Prowirl 200
6:26
Endress+Hauser
Рет қаралды 129 М.
Turbine Flow Meter Explained | Operation and Calibration
8:05
Types Of Flowmeters And Their Industrial Applications.
12:46
James Sword Engineering
Рет қаралды 107 М.
Potentiometric pH measurement
5:14
Endress+Hauser
Рет қаралды 695 М.
The Ultrasonic Flow Measuring Principle
4:31
Endress+Hauser
Рет қаралды 692 М.
Vortex Shedding in Water
3:46
Harvard Natural Sciences Lecture Demonstrations
Рет қаралды 246 М.
Siemens FC430 Coriolis Meter - How it Works
3:47
GilsonEngineering
Рет қаралды 214 М.
Measuring Principle Pressure
4:53
Endress+Hauser
Рет қаралды 262 М.
Magnetic Flow Meter Explained | Working Principles
10:29
RealPars
Рет қаралды 91 М.
What is Water Hammer?
7:40
Practical Engineering
Рет қаралды 6 МЛН