Thanks for your support. Also Watch Dos & Don’ts of Bathroom Plumbing. kzbin.info/www/bejne/qIm2nHl9nceisLM Like | Comment | Subscribe
@tevitatahi76362 жыл бұрын
7⁷
@howtodoitdude166210 ай бұрын
I prefer the valves higher than the washer for accessibility.
@ignaciofuentes26423 жыл бұрын
I would rather have the water valves be visible for the exact reason you stated in the video. If you have a leak you can see it and you can get to it easily. Seems safer and more practical to me.
@TheBuildingExpert3 жыл бұрын
Thanks for your feedback.
@TK-gd9td2 жыл бұрын
And can easily hide it with a cover or decoration.
@cruisermax2 жыл бұрын
I saw this genius idea at an open house - they had what looked like shower valves above the counter as shut off valves. It was decorative and pleasant looking. It was obvious what they were for.
@marshallferron2 жыл бұрын
@@cruisermax I've been considering something similar. I'm thinking I could hook my pex to a drop ear elbow and then have a couple of nice brass hose bibbs sticking out of the wall. Would be way more secure than PEX in a plastic box and really easy to change the valves. Plus you could hook up a pressure washer to wash the shower.
@StraightPineAcres10 ай бұрын
Yeeupppp. Same
@nohalo4me5554 жыл бұрын
That stinky smell in your laundry room is sewer gas coming from your emergency drain after the water in the p trap evaporates. Solution: Pour water down the drain followed by a cup of vegetable oil. The oil will float to the top forming a barrier that will not evaporate.
@TheBuildingExpert4 жыл бұрын
Or a Trap Primer. Thanks for your feedback.
@scottwebber6523 жыл бұрын
Way to much but it works. I doubt the trap holds that much
@mycats73213 жыл бұрын
Won't the vegetable oil rot and/or attract insects though?
@Mr._Craig2 жыл бұрын
Mineral oil instead of vegetable oil
@MAGAMAN Жыл бұрын
What do you do about the rancid vegetable oil smell and all the bugs it attracts?? Maybe you should just do laundry a little more often.
@bigdadynickable Жыл бұрын
What plumbing code are you using from what country and state ?
@jorgenorman87157 ай бұрын
Could you tie the washer standpipe into the 3 inch clean out drain?
@Megalith793 жыл бұрын
So this was really helpful Info. *But* at the very beginning, you talked about the box height. A lot of newer laundry rooms have the washer and dryer elevated up on a platform of sorts (you can store laundry baskets for example underneath them and it’s easier to get your clothes in and out of front-loading washer and/or dyers with this setup) this elevated position puts the washer/dryer approx 16-20” above the finished floor. So you might want to amend the height of the box to accommodate people installing this particular scenario. Rest of the vid is spot on though 👍🏼
@TheBuildingExpert3 жыл бұрын
Thanks for your feedback
@maintenancebynathan21503 жыл бұрын
Minimum washing machine discharge ht is 39 inches. I place mine just above the top of the back of the washing machines. (44") . You can reach the valves with no problems. Also the discharge can be pulled out and placed into the laundry tub. I don't see the benefit of placing the valves behind/below easy access.
@lucho34103 жыл бұрын
@@maintenancebynathan2150 yea, try telling that to all wives out there
@marydi68912 жыл бұрын
@@maintenancebynathan2150 Agreed lower than 39" (code) will cause overflow problems at the standpipe
@lyrafinnell3002 жыл бұрын
Emergency floor drain is a good idea but if it’s connected to the same drainage pipe only for flooding caused by either hot and cold water being busted, but if your drainage itself is plugged up it is useless. Would it be better to drill a hole put a pvc pipe from your inside to outside wall then cover with metal mesh so bugs can’t get in to avoid flooding? Well this fell for inspection?
@JoeCamel-fn7dl4 ай бұрын
I have a small laundry space. I need to make it wider. My hot and cold shut off valves stick out from the wall 2.25 to 2.5”. Can I install a box like the one on the wall that is recessed?
@mikeyangel10673 жыл бұрын
This is the MOST complete info video I have seen. I send it to al my d.i.y. friends who have done horrors to their homes
@TheBuildingExpert3 жыл бұрын
Thank you.
@maxamillionese85192 жыл бұрын
Your a good friend Mikey
@bellefowler61042 жыл бұрын
A construction company built my house and things are falling apart faster than we can fix them. It seems the entire laundry room needs to be redone. The electrical for the dryer has nearly fallen out of the wall hanging on by one nail and it's so close to the floor that I'm terrified of an electrical fire. Thee pipes behind the washer are so rusted out they've started to collect water across the laundry room floor and into the kitchen. This is beyond frustrating because I don't have the money to call a plumber since everything keeps deciding to fall apart. I haven't been able to do laundry in weeks. So now I'm just researching possible solutions.
@geode23228 күн бұрын
Washer leaks being so rare, that emergency drain p trap will dry out and you'll get sewer gasses under the washer, correct?
@64wbryantex2 жыл бұрын
If you box was high enough to reach and not hidden behind the washer then you could easily turn off the water.
@rogeriorodriguez12123 жыл бұрын
First and foremost good morning, seriously thank you for making this video and sharing the knowledge. This video gave me a lot of good information thank you.
@TheBuildingExpert3 жыл бұрын
Thanks for your feedback 🙏🏼
@joepacheco79798 ай бұрын
What type of joint if sink and laundry drain are on the same side, or is it code for the sink drain to tie into the laundry drain?
@SirBuzz5 күн бұрын
I came here with the same question. I've looked everywhere for the best way to do that and I keep getting conflicting answers
@Blaze49AzSd2 жыл бұрын
Hello , nice vid. I know the code for washer box drain is 2”. My condo only supplies 1 1/2 drains except the toilet drain. Will it be ok if I rough in the 1 1/2 “ If I buy a front load washer which I heard uses less water? I live on the second floor . Any suggestions will be appreciated, thanks
@NicoGbasil Жыл бұрын
What code did you use in this and year? Just curious.
@hoffinator884 жыл бұрын
Very well done. Keep making videos like this on a regular basis, and the people who need this information will find you and subscribe.
@TheBuildingExpert4 жыл бұрын
Thanks.
@bryanciacco4181 Жыл бұрын
My stupid coworkers always mess up the heights of laundry boxes, it's insane! Great video. I'm definitely sending this to them to prove I was right. It's common F-ing sense!
@DavyDave13132 ай бұрын
Not really. If it’s a front load tower this doesn’t matter
@charlesmorgan2234 Жыл бұрын
It looks like you're using a double sanitary tee for a second side-by side fixture (presumably a sink). Shouldn't that be a double fixture fitting instead? Otherwise the pumping action of the washer could cause crossover flow into the second fixture.
@andrewperez36489 ай бұрын
Wondering about this question as well. There is an exception for back to back water closets and/or fixtures, but doesn’t state whether or not the exception (minimum distance of 10x the pipe diameter) applies to an appliance such as a washer or dishwasher. “A double sanitary tee (cross) cannot be used for connections to fixtures and appliances with pumping action because it has a short pattern for change of direction. In addition to blowout-type water closets, 1.6-gallon-per-flush (6.1 L/flush) flushometer tank (pressure assisted) and gravity tank-type fixtures may also produce crossover flow into the opposite fixture connection. The high-velocity flow may discharge through the opposing openings of a double sanitary tee, causing an interruption or blowback at the other fixture. Back-to-back water closets are fixtures that are installed directly opposite of each other and discharge through a short distance into a double pattern fitting. If back-to-back fixtures discharge through several feet of pipe or multiple changes of direction, the flow velocity in the fixture drains would decrease to the point where cross flow would not occur. The exception provides for back-to-back water closet connections to double sanitary tee patterns where the horizontal developed length between the outlet of the water closet and connection to the double sanitary tee pattern is 18 inches (457 mm) or more. The critical distance at which there is potential for crossover is a horizontal developed length of less than 10 times the diameter of the horizontal pipe, for example, 30 inches (762 mm) for a 3-inch-diameter (76 mm) pipe. Once the developed length is over 30 inches (762 mm), the surging flow conditions will no longer exist, and the frictional resistance of the pipe retards the velocity to that of uniform flow conditions.”
@aaronjacobs5794 жыл бұрын
Great clear and simple video. Question, what code are you referring to when saying old and new? Differs by state right?
@TheBuildingExpert4 жыл бұрын
NPC of Canada. However, most of these rules are universal and good starting point.
@scottwebber6523 жыл бұрын
Each to its own but I like the service box above the washer. The valves r accessible w/o movin anything n what is best is I keep m closed when not using.
@TheBuildingExpert3 жыл бұрын
Thanks for your feedback! 🙏🏼
@kelvindunn41873 жыл бұрын
Likewise
@Someothername21343 жыл бұрын
I thought it was a bit funny how #1 was make your valves inaccessible and moments later to install accessible valves. I get Manta's reasoning and it makes for the cleanest room, but I think most people don't mind a little valve box showing in a room that isn't really for show anyway.
@TheBuildingExpert3 жыл бұрын
@garrett Gomes Thanks for your feedback! 🙏🏼
@mycats73213 жыл бұрын
Yup. I like what Ana White did with her laundry room. She had a shelf behind the machines and recessed the plumbing box. She had a flap with hinges that could be flipped out of the way to access the plumbing box. Kept stuff hidden but allowed for quick easy access. Also kept stuff from falling behind the machines.
@SanchoSanto3 жыл бұрын
What if both sink and washer are on the right of the vent pipe? That's what I have and have to come up with a plan.
@TheBuildingExpert3 жыл бұрын
Separate drains for sink & laundry box. Wet vent laundry box drain with sink. Thanks.
@PNdebt-hc2tg Жыл бұрын
If the emergency floor drain has a trap and it dries out what then? No trap primer?
@ncooty10 ай бұрын
@0:30: So now building codes are based on aesthetic preferences? I don't think so.
@TheHalusis2 жыл бұрын
Isnt the Trap arm between vent and P trap? whats that on the left??
@arlenem96972 жыл бұрын
If the water box height is supposed to be 40 inch from the floor and the w/d is 41 tall, what is the reason to have water valves behind the w/d that can't be reached if needed?
@TheBuildingExpert2 жыл бұрын
Please re-watch the video. Thanks
@meansq3 жыл бұрын
Thanks for the informative video. Was wondering if the floor drain can be upstream from the washer drain?
@TheBuildingExpert3 жыл бұрын
Yes, you could do that. Thanks for your feedback.
@mycats73213 жыл бұрын
It is better for it to be upstream than downstream. Either way if you put it too close to the laundry drain, you may get suds coming up in the drain.
@d465129 ай бұрын
My laundry has one 1-1/2 p-trap shared for the sink and washer. Is that code anymore?
@d465128 ай бұрын
@@rickybobby7276 It has one trap for both fixtures. Goes into a san tee in the wall Looks like it's original from the 1980s.
@pargolf31583 жыл бұрын
If the box is lower than the washing machine, how are you going to reach to turn the supply lines off and on without having to pull the washing machine out?
@TheBuildingExpert3 жыл бұрын
@Par Golf It’s mentioned in the video. Kindly re-watch the video. Thanks for your feedback.
@aaltameemi2 жыл бұрын
@@TheBuildingExpert I have same question, I couldn't find answer in the video. Could you please provide simple answer?
@karenwasson93172 жыл бұрын
Would like to add additional visible water line shut offs. Is there a valve box that has a door cover?
@gloriajagus42422 жыл бұрын
Very informative .....I was told my hot and cold water valves are not up to code and the washer drain was wrong .....My house inherited from my 0arents is 60 yrs old .....I just figured it wouldn't be smooth sailing with the installation .....CAN you tell me about codes as far h20 hot and cold tturn off
@bud50849 ай бұрын
One thing people don't understand is that codes change over time. Something that met code 20 years ago may not met today's codes
@cinepost3 жыл бұрын
With the use of an Oatey laundry box, If I were to lower the box so the top of the drain pipe is 28”, could I put the p-trap below the floor? I have a crawl space below the floor.
@TheBuildingExpert3 жыл бұрын
Yes, you can! As long as it’s vented properly, standpipe length is minimum 24” & the trap arm length is minimum 4”. Thanks. 🙏🏼
@mycats73213 жыл бұрын
No. You are not permitted to put a standpipe P-trap below the floor. The trap must be a minimum of 6" above the finished floor and a maximum of 18". From the trap weir up it can go 30" (based on UPC) or 42" (based on IPC). Manta Mechanical means well, but is incorrect about the code for standpipe plumbing.
@mycats73213 жыл бұрын
@@TheBuildingExpert I'm sorry, but you are incorrect: UPC 804.1 Standpipe Receptors. "...No trap for any clothes washer stand pipe receptor shall be installed below the floor, but shall be roughed in not less than six (6) inches (152mm) and not more than eighteen (18) inches (457mm) above the floor..." IPC has the same restriction.
@cinepost3 жыл бұрын
@@mycats7321 then why do we see p-traps below shower drains in the crawl space?
@mycats73213 жыл бұрын
@@cinepost Because shower drains have different code rules than standpipe drains. Sink drains and standpipe P-traps are supposed to be above the finished floor but toilet, bath, and shower, ones pretty much have to be below the finished floor because of how low they are. But they generally shouldn't be lower than 24" from the fixture. The standpipes differ because a pump pushes water out of the washing machine so it has more force.
@worldview7302 жыл бұрын
What happens if you can't change the stack line from 1/1/2" to 2"? How will that effect the flow of the drain line ?
@TheBuildingExpert2 жыл бұрын
It should work just fine. It’s not required to change drains to 2” in old houses where we plumb but might be different where you live. Thanks.
@PBS-nm1uu3 жыл бұрын
great presentation, simple and to the point with illustration.
@TheBuildingExpert3 жыл бұрын
Thanks for your feedback
@joshuamoore24_73 жыл бұрын
It would be a good idea and up to code to put a trap primer on the floor drain and a shut off valve and access panel to to service in a accessable area on a wall near it
@TheBuildingExpert3 жыл бұрын
Thanks for your feedback!
@sweetstradingco.36452 жыл бұрын
what if you have two washing machines (side by side) and 1 drain? Do you use 2 y branches stacked then branched out to 2 separate traps?
@marshallferron2 жыл бұрын
I don't know whether they each need their own traps but a washer is 3 dfu (drain fixture units) and a 2 inch horizontal branch can handle up to 6 dfus so as long as you don't have anything else tied into it then you should be good.
@SandDunesGuy2 жыл бұрын
Question, since the floor drain does not regularly have water in it, doesn't that result in a dry pipe venting gas?
@TheBuildingExpert2 жыл бұрын
A trap primer is the solution. Thanks for your feedback
@rickykelly36812 жыл бұрын
So what’s going to keep water in the emergency drains p trap? If it doesn’t get water in a couple years the p trap water will evaporate and you will be getting sewer gas in your laundry room.
@TheBuildingExpert2 жыл бұрын
A trap primer. Thank you.
@fredmauck69342 жыл бұрын
Please detail the installation of a Gas Supply for the Dryer
@SB-tr1bs4 жыл бұрын
Very helpful, made it look so easy.
@TheBuildingExpert4 жыл бұрын
Thanks.
@edwinaragon48783 жыл бұрын
What state building code does this belong to? Im in Harris county texas
@TheBuildingExpert3 жыл бұрын
NPC of Canada 🇨🇦
@mycats73213 жыл бұрын
@@TheBuildingExpert Ahhh. Ok. That explains why it does not jive with UPC and IPC. The rules are different. I will have to look up NPC at some point.
@vinnygoombatts14583 жыл бұрын
Higher valves enable easy access to cut off the water in an emergency, all my customers really appreciate being able to easily reach the cut offs. Most don't care how it looks most machines in a separate room or garage.
@TheBuildingExpert3 жыл бұрын
Thanks for sharing.
@paulsunner564 жыл бұрын
Very informative thanks!!
@TheBuildingExpert4 жыл бұрын
Thanks for watching.
@PBS-nm1uu2 жыл бұрын
great presentation, straight to the point.
@sangkang62943 жыл бұрын
Laundry floor drain has to be filled with water or the ptrap will dry out in no time.
@TheBuildingExpert3 жыл бұрын
Thanks for your feedback.
@folsomatgranitebay52152 жыл бұрын
Wait what? Stand pipe code is 18”-30.” 24”??
@verticle26122 жыл бұрын
Sweet!
@mattk13582 жыл бұрын
what if my washer is more than 7 feet from the main stack
@TheBuildingExpert2 жыл бұрын
You can run a branch off the main stack more than 7 feet but make sure that 2’’ trap arm length doesn’t exceed 7’11’’. The trap arm is the portion of a fixture drain between a trap weir and its protecting vent.
@travis11903 жыл бұрын
I install appliances and not one person has had a accessible shutoff valve. It's smart too have them.
@TheBuildingExpert3 жыл бұрын
Thanks for your feedback 🙏🏼
@jacob46393 жыл бұрын
Thanks, got me out of a jam
@TheBuildingExpert3 жыл бұрын
Glad it helped.
@epictales13073 жыл бұрын
Good info!
@TheBuildingExpert3 жыл бұрын
Thanks 🙏🏼
@TheBuildingExpert3 жыл бұрын
Thanks 🙏🏼
@popomomo7052 Жыл бұрын
Goode job
@franciscocarrilloperez43433 жыл бұрын
It is UPC codes.
@mycats73213 жыл бұрын
No. It does not reflect any actual codes. The information is incorrect. The 24" rule refers to sink and shower traps. Laundry standpipes are in a different category. UPC 804.1 Standpipe Receptors. Plumbing fixtures or other receptors receiving the discharge of indirect waste pipes shall be approved for the use proposed and shall be of such shape and capacity as to prevent splashing or flooding and shall be located where they are readily accessible for inspection and cleaning. No standpipe receptor for a clothes washer shall extend more than 30 inches (762 mm), or not less than 18 inches (457 mm) above its trap. No trap for a clothes washer standpipe receptor shall be installed below the floor, but shall be roughed in not less than 6 inches (152 mm) and not more than 18 inches (457 mm) above the floor. No indirect waste receptor shall be installed in a toilet room, closet, cupboard, or storeroom, or in a portion of a building not in general use by the occupants thereof; except standpipes for clothes washers shall be permitted to be installed in toilet and bathroom areas where the clothes washer is installed in the same room.
@MAGAMAN Жыл бұрын
Sorry, I'm not re-plumbing my house because they changed the code.
@Zip22Zip2 жыл бұрын
I don't care if I see the laundry box. If I can it means I can turn the water off there without much difficulty.
@bryang91587 ай бұрын
The at least 24 in drain pipe is false it's between 18 and 24, edit my bad it's different state to state
@mycats73213 жыл бұрын
I very much appreciate this video. It is well done. You speak clearly and concisely, however, there are some errors. I am not intending to be rude or condescending, but I would like to correct some of the information as well as add some feedback. The point is to make sure people know the correct rules. Perhaps you can do a revised video if you want. The 40" rule is not what the plumbing codes say. The 24" thing is also not what plumbing codes say. IPC allows for the drain to be 42" maximum above the trap weir. UPC has a 30" limit. That is on top of the trap weir being a maximum 18" above the floor (both IPC and UPC). So maximum height of the drain in a laundry box in UPC is 48" and maximum height for IPC is 60". The minimum height of the pipe above the trap is 18", not 24". I believe the 24" rule applies for sink and shower drains. *IPC 802.4.3 Standpipes. Standpipes shall be individually trapped. Standpipes shall extend a minimum of 18 inches (457 mm) and a maximum of 42 inches (1066 mm) above the trap weir. Access shall be provided to all standpipes and drains for rodding.* *UPC 804.1 Standpipe Receptors. ...No stand pipe receptor for any clothes washer shall extend more than thirty (30) inches (762mm), nor less than eighteen (18) inches (457mm) above its trap. No trap for any clothes washer stand pipe receptor shall be installed below the floor, but shall be roughed in not less than six (6) inches (152mm) and not more than eighteen (18) inches (457mm) above the floor...* *IPC 1002.1 Fixture traps. Each plumbing fixture shall be separately trapped by a water-seal trap, except as otherwise permitted by this code. The vertical distance from the fixture outlet to the trap weir shall not exceed 24 inches (610 mm) and the horizontal distance shall not exceed 30 inches (610 mm) measured from the centerline of the fixture outlet to the centerline of the inlet of the trap. The height of a clothes washer standpipe above a trap shall conform to Section 802.4. A fixture shall not be double trapped.* Ana White hid her laundry box behind a door that flipped up, but honestly, I don't mind seeing the laundry box. I want it to be easy to reach/access in case of emergency. There are ways to conceal it where it can still be accessible though-- but you can have it higher than 40" and not have it look ugly. I do like how your picture has two separate boxes for water supply and drain. I don't know if I can do that in my layout. I'm hoping my box will let me put the drain on the right and supply lines on the left. I want to have the box sort or embedded in a shelf with grommets that the hoses go through to reach the box. It will keep stuff from falling behind the machines and make things look a little cleaner. If I don't like being able to see the box & hoses I can add a hinged flap to cover it. Extra shutoffs near the floor are a good idea if the laundry outlets leak or have a problem. Although, as I said before, I personally like to have the shutoffs for the machine hoses to be easily accessible. I would also put the cleanout for the vent higher up-- above the flood level of the fixture in case water backs up the pipe. You don't want it spilling out when you go to snake it out. When merging the washing machine's 2" line with the main sewer line, you want to increase it to 3" to improve flow. Floor drains will need to have water poured down to seal the trap if there haven't been any leaks. You may need to add water if it evaporates in the trap. As for the laundry sink (if you can fit one, you may want to have a branch vent and be mindful of backwash from the washing machine. Sometimes suds can back up in to nearby fixtures if they are plumbed too closely. I will add that on the electrical side: 20amp GFCI outlet should serve the washing machine. This is not a code requirement specifically for the washing machine, but it is a code requirement for laundry areas. Anything within 36" of potential water spray should be GFCI unless you have a GFCI breaker. I would do my best to keep the plug out of the splash zone and somewhere that is easily accessible to unplug in an emergency. Same with the dryer. For the dryer you want to upgrade to a 4-prong plug & receptacle. The old 3-prong ones can cause the dryer to become electrified and result in electrocution.I am not intending to be rude.
@rickybrown65853 жыл бұрын
You can't put a cross connection with a pumping action machine...the reason why I'm watching is to see how I can tie in a sink above the C.W. here I see an obvious mistake
@TheBuildingExpert3 жыл бұрын
It may be different where you live but NPC of Canada doesn’t restrict the use of cross tee. Thanks for your feedback.
@rickybrown65853 жыл бұрын
@@TheBuildingExpert it's not the use of cross tees...it's having a pumping action fixture like a clothing washer on a cross tee...It's for a reason and I'm sure it's the same out there
@andrewperez36489 ай бұрын
Wondering about this question as well. There is an exception for back to back water closets and/or fixtures, but doesn’t state whether or not the exception (minimum distance of 10x the pipe diameter) applies to an appliance such as a washer or dishwasher. “A double sanitary tee (cross) cannot be used for connections to fixtures and appliances with pumping action because it has a short pattern for change of direction. In addition to blowout-type water closets, 1.6-gallon-per-flush (6.1 L/flush) flushometer tank (pressure assisted) and gravity tank-type fixtures may also produce crossover flow into the opposite fixture connection. The high-velocity flow may discharge through the opposing openings of a double sanitary tee, causing an interruption or blowback at the other fixture. Back-to-back water closets are fixtures that are installed directly opposite of each other and discharge through a short distance into a double pattern fitting. If back-to-back fixtures discharge through several feet of pipe or multiple changes of direction, the flow velocity in the fixture drains would decrease to the point where cross flow would not occur. The exception provides for back-to-back water closet connections to double sanitary tee patterns where the horizontal developed length between the outlet of the water closet and connection to the double sanitary tee pattern is 18 inches (457 mm) or more. The critical distance at which there is potential for crossover is a horizontal developed length of less than 10 times the diameter of the horizontal pipe, for example, 30 inches (762 mm) for a 3-inch-diameter (76 mm) pipe. Once the developed length is over 30 inches (762 mm), the surging flow conditions will no longer exist, and the frictional resistance of the pipe retards the velocity to that of uniform flow conditions.”
@JesseWright683 жыл бұрын
Great video, but do away with the distracting music. It doesn't serve a purpose and diminishes your message.
@TheBuildingExpert3 жыл бұрын
Thanks for your feedback
@brianfaulhaber67852 ай бұрын
Flood rim level
@TheKaffeeKlatsch2 жыл бұрын
Emergency!
@cristhmc12 жыл бұрын
Nothing but clowns 🤡
@MRYOUNG1234512 жыл бұрын
Why can’t you make a video and get your point across without the bullshit I want to be like everyone else musick playing that’s mixed so high it just annoying and we can’t focus on what the dialogue is!
@fredmauck69342 жыл бұрын
Please detail the installation of a Gas Supply for the Dryer