Muchisimas gracias Jeferson!. No puedo suscribirme a tu canal pero te puedo pagar un cafecito porque este video me resulto super util!
@jefersoncostaengineer2 жыл бұрын
Hola Silvia, se puedes compartilhar este video y otros con las personas lo cafecito esta pago 😁 (Forgive my Portunhol 😂)
@Neo.467.35 Жыл бұрын
Great video! Thank you!
@jefersoncostaengineer Жыл бұрын
Thanks for your positive feedback 😄
@HashimKareem-y3y Жыл бұрын
Hello Jefferson, First of all, I would like to appreciate your hard work and thank you for sharing this. Also, I want to ask you, why have you considered NG-210 stream as a reference stream instead of NG-400? Please, I need the concept of this. Thank you in advance!
@jefersoncostaengineer Жыл бұрын
Hi, you need to select the stream source of overpressurization. In the example, NG400 in normal operation will have pressure below PSV set point. However, if the control valve fails open, pressure can increase up to NG operating pressure or PSV set point.
@anicarlis2 жыл бұрын
Hello, thank you very much Jeserfon for sharing your knowledge and experience in this area of process engineering simulations. I wanted to ask you how I generate the safety analysis report, since I tried it in the traditional way from the main simulation and it only reports the scenario, it is not including all the results (hole, lines, etc.) in the report . Could you please guide me for that if it is not a bother? , many thanks in advance. Cheers
@jefersoncostaengineer2 жыл бұрын
Hi Anicarlis, basically you need to have Aspen Basic Engineering (ABE) set in worder you can create a workspace on Hysys/Plus and issue PSV datasheet
@mehfuz.ansari3 жыл бұрын
Thank you sir for the detailed explanation. I need to know how to take print of PSV Calculations and Datasheets within HYSYS Safety Analysis. Its asks for Project URL. Solution to it?
@jefersoncostaengineer3 жыл бұрын
Hi Mehfuz, you need to configurate the Personal Workspace
@nasro18533 жыл бұрын
I really thank you for this sharing my name is goussas nasro ddine from algeria I am 8 years process engineer experience with sonatrach and pertamina ♥️
@jefersoncostaengineer3 жыл бұрын
Thanks for sharing your background Nasro :)
@muneeburrehman6972 Жыл бұрын
HI, good work. can you please elaborate the critical velocity in outlet line sizing of PSV. As per API Psv tail pipe (outlet line) size on 0.7 Mach#. Does hysys use the same criteria? and this critical velocity is speed of sound at given process conditions?
@jefersoncostaengineer Жыл бұрын
Hysys to not size the pipe. You are able to verify the conditions adding pipe to your system.
@yagout7 Жыл бұрын
I am trying to follow this tutorial for PSV sizing, my question is do I have to create the other elements my self (lines and separator..etc.)?
@jefersoncostaengineer Жыл бұрын
I did not get the question Fuad. To place your PSV with Aspen Hysys you need to have at least a material stream fully specified. Scenarios will depend on what information you have available.
@yagout7 Жыл бұрын
@@jefersoncostaengineer Thank you for your answer. I actually don't have any streams available at the moment that's why I wanted to copy your streams so I can place the PSV. I am just trying to understand the steps without having many inputs from my end. Thank you again Mr. Costa.
@achokomanpatrickherve70794 жыл бұрын
He thank for your explaination. I need PID's dévelopment exercices with corrections in order to improve my level in.this difficult activities on PID . Please send me documents with exercices about it. Thank
@mohdshafuansaffiei81713 жыл бұрын
thank you very much, sir!
@praneetlohakare57133 жыл бұрын
Can you tell me how to unhide the PSV in process simulation window? or How to transfer PSV from Safety Analysis to process simulation window?
@jefersoncostaengineer3 жыл бұрын
Hi Praneet, PSV on standard simulation and PSV in Safety Analysis are used in different ways. The main purpose of Safety Analysis is to allow you to calculate relief flow rate in different scenarios and base on that select PSV size. In the standard simulation you can use the orifice calculate on Safety Analysis. More about it in my telegram channel Inprocess. I will record an audio with my comments there. All links at www.jefersoncosta.com
@praneetlohakare57133 жыл бұрын
@@jefersoncostaengineer Hello Jeferson, Thank you for your reply. It absolutely clear my doubt.
@andreshernandezbernal3336 Жыл бұрын
How can I get a report of this calculation for the PSVs?
@jefersoncostaengineer Жыл бұрын
Hi, you need to click in datasheet. You need to have your workspace set.
@elsyaif354 Жыл бұрын
Hello... How to print the full report? Anyone know?
@jefersoncostaengineer Жыл бұрын
To get PSV datasheet you need to click on DataSheet avilable on the tab Home. It will link you to Aspen Basic Engineering (ABE) tool. If it is set, you will be able to select and print PSV report.
@elsyaif354 Жыл бұрын
@@jefersoncostaengineer thanks you
@ansonhenry63712 жыл бұрын
How gases are shown in units using scalar squares--Nm3/h
@jefersoncostaengineer2 жыл бұрын
Hi Anson, you just need to change it in unit set.
@jayeshbarad67262 жыл бұрын
Which Laptop is best for Process engineer ? Anyone Help me ?
@jefersoncostaengineer2 жыл бұрын
Hi Jayesh, my recommendation to run process simulation software is 8 GM RAM and 256 SSD as a minimum. I have a Dell with i5 processor. I do not see any need for separated graph processor.