This one was tough to film, hope you find it useful. Please sub if you like the content 😊
@abdoaiman7 ай бұрын
Working in lofts is the worst believe me.. All the hard work & effort is Much much appreciated. ❤
@muffinbubble7 ай бұрын
Appreciate all the efforts. Definitely sound from down near my way (Norwich).
@tetedur3776 ай бұрын
Yeah, I stopped watching at the 1:59 mark. You were up in the attic, you had your hole saw; how hard would it have been to drill...I dunno...DOWN. Even if you only drilled through with the pilot bit, then drilled the rest from the stall. Sorry, mate; no sub from me. Cheers.
@yousefrostami5 ай бұрын
Thanks for the video; it was really helpful. Does the fan have a timer that can be set to a specific running time?
@daniellemon64982 ай бұрын
@@tetedur377because he’s not rough like you and doesn’t want the finished surface to blow out
@RB-xg2vz7 ай бұрын
One tip I picked up for CRJ Electrical channel is to put rubber grommets (the type you use in metal back boxes) under the 4 mounting points of the fan and then screw the fan down - reduces vibration noise.
@TheDIYGuy17 ай бұрын
Sounds like a great tip that and something I’ve never done 👍
@freddieleethompson35367 ай бұрын
I do the same but use tap washers.
@kuk34117 ай бұрын
You can also take two pieces of ply screw the first to a joist and attach the second on top with beaded silicone lowers the amount of vibrations through to the joist
@schmutzlibuab7 ай бұрын
It's almost like you know what I need to do in our house! 🤣 Another brilliant and easy to follow guide. Thank you DIY King 👑
@Participant6167 ай бұрын
I screw these fans through cheap gardeners' kneeling pads, about £5 a pop from Amazon.
@alanantliff351528 күн бұрын
Clear, excellent video and diagrams. Installed the same fan. Used the same Manrose 100T fan but hung from roof truss, supposedly less noise. Going to change over the one metre PVC flexi duct coming from fan to gable wall due to condensation in the duct during winter. After i installed it i asked my electrician to wire the fan separate to the light as originally fan came on with light, which was a pain when using the shower during the day, and the light was on! Much better now with the fan and light separate!
@ppeaster7 ай бұрын
I used this video to finally replace our rubbish noisy old fan with the Manrose inline model you fitted. Really happy with it - much more powerful and so quiet. Thanks for giving me the impetus to get it done as it's been annoying me for years.
@TheDIYGuy17 ай бұрын
Glad to have helped out!
@GardenreetLighting7 ай бұрын
I loved how you covered everything from start to finish! 😊 Whether it's wiring up a fan isolation switch or installing the ductwork, you left no stone unturned.
@TheDIYGuy17 ай бұрын
Glad it was helpful! That was my plan 👍
@Darryl3982 ай бұрын
In the last hour, you've shown me how easy it is to deal with my steamy bathroom, fix my squeaky steps, and sort out my crap bathroom silicone finishing. Absolute hero.
@andyg00d7 ай бұрын
Found this in my feed literally two minutes after my new Manrose fan was delivered... Google knows me too well! 😆 Some info on condensation traps would be great, but very comprehensive video, great job!
@FatherJHackett7 ай бұрын
I've had the same fan since we bought our house 7 years ago. It's in the attic... in the box it came in, yet to be installed. Maybe after watching this, I'll finally install the bloody thing! 😂
@TheDIYGuy17 ай бұрын
Hah do it! 😊
@lifter987 ай бұрын
Same here, only - 4-yrs though..
@chrissyp74336 ай бұрын
Same here 1yr just have to wire it in now.
@jeremycarr6915Ай бұрын
That is how it is done. My cowboy has the ducting at a 45 degree angle and no condensation trap. Oh, and no fan isolator as the job was done about 10 years ago. Time to get a professional in- great to have someone with a pride in their job to show what excellence looks like.
@mikeevans90623 ай бұрын
Further to my previous comment. We never used the soffits again. We found roof tile vents much better as the ducting worked better being as short as possible and going in a vertical direction. I do like your use of insulation around the duct that will help with condensation in the duct where it lyes flat on the joists.
@haddenhamvillagesociety841526 күн бұрын
Others may have already pointed this out but many soffits on older properties were created with asbestos boards - you need to be much more protected with a high performance PPE respirator before cutting the aperture - especially when doing so from below.
@stephenford4074Ай бұрын
Thank you so much for this video. My crappy sf100t packed up…followed this video and installed the MF100t….wow what a difference- thanks!
@DTech1017 ай бұрын
I always use ridged pipe stops turbulence and the build up mould in the duct. You said hard to find a fan with that extraction rate but for my downstairs bathroom fan installed over the shower area ridged ducting under the floor board this is the answer Airflow iCON60 Circular Extractor Fan for Large Bathroom, Utility Room or Kitchen 280mhr/78 ls but it’s a beast! PS I would get a humidity sensor wired up they do one that will work with that fan works good 👍🏾
@TrickyTree845 ай бұрын
Ok used rigid tubes and they are so much louder I defo do not recommend it. Fan noise and noise from outside
@DTech1015 ай бұрын
@@TrickyTree84 louder maybe more airflow definitely I just suppressed the noise with slabs of rockwool, as extraction rate is what is really needed.
@TrickyTree845 ай бұрын
@@DTech101 I found the fan itself louder though as the sound resonance in the tubes is greater and sound more easily carries in from outside.weapping in rockwool won't stop that. Yes more air flow but not worth it in my experience.
@Mark-jw7wr2 ай бұрын
Your posts are always very good. I was looking for how to replace the bathroom ceiling vent fixing and cover as existing one was getting yellowed and brittle. Your demonstration and tips in this video was simply perfect. Couldn’t have been more clear and helpful. Thank you.
@freddieleethompson35367 ай бұрын
Literally just fitted two of these on my current job. I always recommend these to my customers.
@TheDIYGuy17 ай бұрын
Deffo a great fan 👍
@jeffjeffjeff27 ай бұрын
Fitted one of these manrose fans a couple of years ago and it's so much better than the small inline fan type as you say. My only regret is not upgrading the ducting at the same time to the insulated type. I'll have to get a handyman to do it now as access is so poor into my eaves. Good video and you've got +1 subscriber from me. Cheers
@MadDog_Rules7 ай бұрын
Thanks!
@TheDIYGuy17 ай бұрын
Thanks to you too 👍
@dalegreenuk7 ай бұрын
Been putting off replacing my dying fan for a while but it was getting closer! Perfectly timed. Purchased my first house recently and your videos have been insanely helpful. Thank you. :)
@TheDIYGuy17 ай бұрын
Glad to help 😊
@CB-DW7 ай бұрын
Installed one of these 2 years ago. So much more efficient than the usual extractors and quieter too!
@TheDIYGuy17 ай бұрын
Absolutely 👍
@cgo2257 ай бұрын
Thanks for the vid..... I've just had my new extractor fitted used solid tubing with a slight fall to the outside vent to drain any condensation to the outside, also added rubber grommets under the fan to minimise vibration, plus removed the flyscreen to prevent build up of fluff/dust and added a backdraught flap which keeps the bathroom draught-free especially in winter.
@TheDIYGuy17 ай бұрын
👍
@twelveightyone3 ай бұрын
Just moved into a house with no extractor fan and will be following your video when I install my new one. Thanks for this, it's really informative and very well presented. +1 follower.
@jonstobart46197 ай бұрын
These fans need fusing down which I did via a spur with a 3a fuse, I didn’t realise that you could get a fused isolator. Live and learn. Great video
@neiltrevatt7 ай бұрын
Did you have a fan with a timer if so how did you fuse both sw & permanent live
@Dr.Stacker2 ай бұрын
@@neiltrevatt Same question, The only fused triple pole isolator I've seen has only one fuse and won't fuse against both L & SL
@JoshoptimuscrimeАй бұрын
@@Dr.Stackerdid you find out in the end? I’m due to install one soon
@youthfulrider4077 ай бұрын
Just a tip for the less powerful fans, with the duct work I would always recommend using solid ductwork as opposed to flexi. Better air flow, less resistance, less dirt and bacteria captured over time, Also undercut the door to allow make up air.
@TheDIYGuy17 ай бұрын
👍 thanks for sharing
@willwoodvine1437 ай бұрын
I installed the Timer version of the Manrose fan over the shower and also have an always on version (set to lowest speed) in the main part of the bathroom. Did this late last year and we've had no issues with condesnation, mould or "lingering smells" :) Must admit I'm surprised at how quiet these fans are, no need for anti-vibration measures at all.
@danlux49542 ай бұрын
Is the fan rated for always on?
@lenrichardson73493 ай бұрын
That wiring model was very helpful to understanding what people have done before, so even if I don't do anything I know what might be needed.
@kevinthegerman12 ай бұрын
Excellent video, thanks for doing this. Though I'll be okay through having taken notes, a downloadable/printable wiring diagram would be so helpful for when I'm up in the loft etc, when you just want a printout to make sure you're doing it right.
@DaxMayarex29 күн бұрын
I subbed for that demo piece that you made, great teaching aid... I'd have really liked it if you had shown wiring up the dummy, would make for a great short video that people could follow along to.
@simonbeasley9897 ай бұрын
I fitted one a few years ago, those fans are brilliant. The bathroom had mould when I bought it as the builders in 2005 fitted a pathetic mains fan in the ceiling nowhere near the shower and bodged the ducting and I swear it couldn't hold a sheet of toilet paper up because I tried it! The Manrose can hold a flattened toilet roll middle up! And instead of motor vibration the main noise is the rather more pleasant whoosh of airflow.
@TheDIYGuy17 ай бұрын
Absolutely 👍
@patrykgorecki5812 күн бұрын
Works quite loud....Great video!
@MiteshParmar7 ай бұрын
We just our roof done and install a roof vent tile. Made a big difference the air goes straight up and out. No fiddly bends like before for us.
@TheDIYGuy17 ай бұрын
Nice one 👍
@RogerHolden7 ай бұрын
I've installed one of these, but only after first buying the version without a timer - so be aware that that exists. It didn't even cross my mind that they wouldn't have a timer, thus didn't check the spec, like you wouldn't check the spec of a car to check it has a steering wheel! Screwfix brilliant as ever and exchanged it for the (more expensive) timer version. I've also turned mine down to the lowest power setting as thats fine, and it was surprisingly noisy on medium or high.
@NeonXXP4 ай бұрын
Really good extractor, I put one in the shower room of my grandad annex. Gonna use the same for my new bathroom and en-suite.
@thejoneseys7 ай бұрын
This video is perfectly timed, I'm ripping out my ensuite and redoing the builders garbage effort (many things wrong including leaks) and I'm putting one of these fans in at the same time 👍
@TheDIYGuy17 ай бұрын
Glad I could help!
@deanwellerassociates7 ай бұрын
Very made and edited video. Just what I needed to explain this type of install to my son, I bet he will listen to you far better than for me. Cheers. Time for a cold one.
@TheDIYGuy17 ай бұрын
I appreciate that! Show him and I hope it helps him too!
@Ste20236 ай бұрын
Love your channel . Easy to follow No BS . those In line extractors look well better
@TheDIYGuy16 ай бұрын
Thanks 👍
@steejayk5 ай бұрын
Wow.. just wow.. I found this channel only today, watched about 10 videos so far.. Super useful and well explained.. Great work
@TheDIYGuy15 ай бұрын
Thanks and welcome
@built_not_bought2 ай бұрын
Brilliant video! 👌🏻 Thanks for filming this, really clear instructions throughout and the demonstration board was perfect to help break it down! Managed to install a HIB Cyclone from scratch with zero issues 😊
@simonpartridge96837 ай бұрын
Thanks for showing this, I've got one to install completely and one to put an external vent on.
@TheDIYGuy17 ай бұрын
Glad I could help 😊
@mikeevans90623 ай бұрын
Many years ago I installed a kitchen extractor vent in a soffit as you have done. It was a new build and we had a building control officer come and inspect he wasn’t happy and said it contravened building regs as the moist air would have detrimental effect on the soffits and fascia. I don’t think I’ve seen this extraction position on any new builds.
@stuartday18767 ай бұрын
Just used the exact same fan for our bathroom, the performance is amazing. I used solid pipe from the fan out through the gable end, just because I worried about moisture pooling inside a long flexi pipe. I have a small drop on the solid pipe, so it's all downhill to the gable vent.
@stuartday18767 ай бұрын
P.S. the electrics blow my mind, but luckily I have a brother in law who is a sparks who broke it down into simple instructions😂
@TheDIYGuy17 ай бұрын
Yeah if you’ve a long run it was probably the best way 👍. Nice work
@dougle037 ай бұрын
Now I know the manual shows flexible ducting but.... Air ducting is always better when the inside of the duct is smooth. For such a short run I'd have been using 4" tube with an insulated wrapper. the rough surface in flexible ducting slows down the air travel, it causes turbulence and reduces the efficiencies of the fan. Perhaps not a problem for this install since it's a short run, but worth using a couple of lengths of tube between flexible angle joints. Cracking video, and I could feel your pain filming in that heat... 👍👍
@flyingwhiteindian7 ай бұрын
I dont understand why the tube has to be insulated - isnt it just taking the air outside. What does the insulation achieve/
@dougle037 ай бұрын
@@flyingwhiteindian In the winter if the duct was not insulated it would get very cold and the steam would condensate in the duct before getting outside which is not desirable.
@narrowboatlongpod41767 ай бұрын
@@flyingwhiteindian Condensation forms and runs back inside. You can get traps to take this away but it's not usually practical.
@towkukus2 ай бұрын
what air ducting would you recommend??
@simonbriggs6332Ай бұрын
I’ve just swapped an in ceiling style fan which just wasn’t clearing the bathroom of steam with 1 of these style in extractor fans. Doesn’t seem to have made much difference at all even though it’s got almost 3x airflow rate. Whilst I was upgrading the fan I also used solid pipe from the intake vent in ceiling to the fan itself (flexi ducting from the fan exhaust out to the eaves vent as that’s difficult to get to)
@rss1127 ай бұрын
Top video mate! Just what i was looking for! Might of been worth adding that the door for the bathroom should be cut back to allow air flow. But over all great video. I will be installing one of these in the summer.
@ftumptch862 ай бұрын
Ive got mine screwed loosely down on 4 layers of carpet underlay. Dampens the vibrations a treat.
@phillipmedinarepairdcmotor8357 ай бұрын
Thank you very much man you have me so much I have a brass pipe I transfer to pvc I was kind of confused and I know what to do I was watching too many videos and you are the only one number one
@ianfaulds87997 ай бұрын
Great informative video thanks, one of my summer jobs fit loft lighting and a new shower fan and youve covered both in detail thanks so much.
@TheDIYGuy17 ай бұрын
Awesome, thank you!
@slowridr7 ай бұрын
We had the same setup fitted in our new en-suite recently, it’s outstanding and going to do the same in our new bathroom. Wiring it up is a bit confusing for me though, a job for the spark!
@TheDIYGuy17 ай бұрын
Definitely worth it 👍
@phillipmedinarepairdcmotor8357 ай бұрын
I just want to say thank you so much I was so confused and working in my bathroom right now and I don't know what to do thanks to you I want your video and I'm really happy because I have a brass 5 and I transfer to PVC thank you so much
@MrBinabanana7 ай бұрын
Great video, but one little thing worth mentioning is that any electrical requirement in the installation instructions for any accessory need to be adhered to in order for the installation to be compliant with wiring regulations, and most of these shower fans call for 3A fusing on both the permanent and live cores - so the usual 6A MCB for the lighting radial isn't sufficient for compliance. I usually install a separate single backbox next to the isolator with a 2-way grid plate containing two fuse holders fitted with 3A fuses. It's an added expense and arguably overkill, but technically needs to be done in order to make the installation 100% compliant.
@Dr.Stacker2 ай бұрын
That seems like a lot of wires and 3x back boxes (inc the light switch). Could you instead have a 3a fused DP FCU somewhere in the loft next to the fan? Thanks
@robertd-dh8qm7 ай бұрын
i wish you lived near me . a good tradesman is hard to find. Love watching your videos 👍
@TheDIYGuy17 ай бұрын
Thanks, appreciate the support
@MRBCRYPTO833 ай бұрын
Just installed this same setup today, thanks to your tutorial. Gave me all the confidence I needed. Thanks 👍
@terrywalker47337 ай бұрын
Great job done, I know what it’s like working in a loft with loft insulation. Many thanks for the detailed video.
@TheDIYGuy17 ай бұрын
Thanks. It’s tough especially with a camera 😆
@robertkerby25817 ай бұрын
I really liked your easily digestible KZbin video! Well done, Sir!
@TheDIYGuy17 ай бұрын
Thank you very much!
@pel7877 ай бұрын
Good to see you using insulated ducting
@TheDIYGuy17 ай бұрын
👍
@knottstarr7 ай бұрын
What is the purpose of the insulated ducting over normal flexible plastic ducting? Thanks
@pel7877 ай бұрын
Condensation
@prawncracker13044 ай бұрын
That Electrical guide was excellent. Thanks
@jsouto777 ай бұрын
Great video. It would be nice to have a humidistat option with maybe a wireless humidistat possibly but I suppose this could also be possible with a bit of ingenuity.
@Allsystemsaredown7 ай бұрын
Great video! The explanation of the wiring was fantastically clear. Top marks!
@TheDIYGuy17 ай бұрын
Glad you liked it! Thanks
@jonathanwilliams79507 ай бұрын
The Manrose MF100T instructions state it must be fitted to a circuit with a 3A fuse. 18th edition states manufacturer's instructions are taken into account for electrical installation. I use a double pole fused spur as the isolator with a 3A fuse fitted and a double pole light switch so the lighting circuit and extractor circuit are switched separately when installing these.
@jayseabie2157 ай бұрын
Good idea! No need for the fan to always come on when you're just popping in for a quick pee!
@jonathanwilliams79507 ай бұрын
@@jayseabie215 for that you'd probably want to fit a humidistat
@acelectricalsecurity7 ай бұрын
Click make a fan switch that has a 3amp fuse built in, the vast majority of fans will require a 3amp fuse, there are not many on the market that don't
@bertbox697 ай бұрын
Always better to have a seperate fused spur for fan, hate it integrated with and dependent on light switch
@acelectricalsecurity7 ай бұрын
@@bertbox69 personally I am not keen on timed fans, if you want a shower or bath in the daytime you either have to have the lights on or flick the lights on or off, a separate on off switch is best.
@theblower0697 ай бұрын
thank you very much for this video this is something we need in our house as it doesn`t have an extractor in our bathroom. i will need an electriction though as i`m not competant enough to do the electrical work. a very good video. thank you.
@TheDIYGuy17 ай бұрын
Glad to help. Definitely give an electrician a shout 😊
@theblower0697 ай бұрын
@@TheDIYGuy1 I will and costing out the parts isn`t that much. once again thanks
@JW-bp9uw7 ай бұрын
Great Vid!! Did the same and also included a Back Draught Shutter
@gmeadowcroft847 ай бұрын
Cracking vid mate. Really well installed. One point though that is a safety issue. The wiring between the fan and the 3 pole switch should have a 3 amp fuse installed. I’m not sure why this is as to me it’s a bit pointless but 90% of manufacturers state that it has to be there in the installation guid. Please don’t think I’m being a keyboard warrior as that was a cracking install you did there just a point I picked up that’s all.
@TheDIYGuy17 ай бұрын
Cheers 👍
@ef74807 ай бұрын
An observation- the Wago 221 connectors should be used with the Wago 221-4 junction box with the 3 compartments to be maintenance free (although yours is accessible in the loftspace). The Wago box with the 2 compartments at the end like yours is for the 772 and 333 connectors for a maintenance free connection, just in case someone uses the wrong combination and hides it under floorboards or in a wall. The 2 compartment box can be converted to MF with inserts from Wago👍
@shmink27 ай бұрын
The internal plastic of the ducting I personally like to electrical tape that onto the fan and vents. It gets a nice air tight seal and then I'll push the rest of the ducting over that (insulation and out sheet) and then zip tie that to just minimise it moving.
@AdrianWT-j9nАй бұрын
Before you do anything, especially drilling, make sure that ceiling is not containing asbestos guys.
@Ibrahim-vt2tz2 ай бұрын
very nice very nice way and clear of explanation of wiring fan thanks
@Chris-BognorRegis4 күн бұрын
Brilliant update. My question is that my Manrose fan goes up to the roof into a platsic tile vent, rather than a vent in the soffit. Was like that when I moved in. So is the roof vent better than the soffit vent?
@jsb74297 ай бұрын
Good video. I fitted one except the fan on the joist causes vibration. Tried mats and rubber under fan, no difference. Finally had to hang it from the rafters with chains. Fan sits on a board like a swing.
@psr11335 ай бұрын
Great video. One question I got. Has the isolator switch got the 3amp? “The installation must have an omnipolar switch with a contact separation of at least 3mm. The circuit must be protected by either a 3 Amp fuse or suitable 3А МСВ.”
@kn4cc7557 ай бұрын
Independent of this video, I installed a similar fan about a year ago. It works well. Too well. With it at maximum speed (mine is variable), it is louder than a 747 on a short takeoff roll.
@TheDIYGuy17 ай бұрын
They are good. The sound is more air suction sound rather than fan vibration
@lukeclarke17437 ай бұрын
Really well explained and great video . Top job mate
@ShedTV7 ай бұрын
We use the Ventaxia version of these where I work in a theatre to pump smoke onto the stage. They're more expensive but much quieter.
@TheDIYGuy17 ай бұрын
👍
@DjGiluk7 ай бұрын
Great job 👍🏻 helpful wiring diagram, reminds me of your older wiring videos 👌🏻
@TheDIYGuy17 ай бұрын
Thanks as always 😊
@DerekTJ2 ай бұрын
Id love a video of you just saying "humidity". 😊
@shirleyc285Ай бұрын
Thinking of getting a quadrant shower put into our bathroom. Didn't even realise we should have an extractor fan put in as well for it....😮
@johnadams19767 ай бұрын
if only those fans could connect to a smart home system.... combined with a humidity sensor in the bathroom... the overrun could then be controlled by the humidity in the room and not just a fixed timer. Great vid as always.
@TheDIYGuy17 ай бұрын
Great point! Thanks
@David-dz8jb7 ай бұрын
I recently fitted a inline bathroom fan and fused it down to 3a as per manufacturers instructions (this is their get out clause in case of problems) you could make up a multi gang switch plate to fuse both line and switch line together with a three pole isolater but it gets a bit over the top and messy. The best solution I found was fit a smart switch cheap as chips which is linked to Alexa and I find this the very best for complete control over overrun I just ask Alexa to switch on the fan and on it goes for 20 minutes you can alter the settings by just asking Alexa “ turn on fan for xx minutes” and of course you don’t need to have the fan running at all for a trip to the loo at 3am. Probably not the best solution for a enclosed bathroom where I would guess a light linked fan would be required but in my situation this works the best.
@johnadams19766 ай бұрын
@@David-dz8jb In the end I bought this fan.... which is connected to the isolator of the old one.... inline I put a Sonoff Basic R2, which I flashed with Tasmota for 100% local control. I placed a Zigbee humidity sensor in the bathroom, and another in the hall way. Everything is connected to Home Assistant. An automation is triggered if the bathroom humidity sensor is 8% higher than the one in the hall (i.e. someone is using the shower!!!) the fan automatically comes on until the humidity sensor in the bathroom is within 3% of the one in the hall. Works absolutely perfectly. I'm also putting a Zigbee button in the bathroom to press if you want a 3 minute fan extraction - i.e. you've done a poo!!!!!! LOL!!!!
@asifchoglay60135 ай бұрын
@@johnadams1976 superb.
@johnadams19765 ай бұрын
@@asifchoglay6013 I realised that 3minutes per poo was not enough!! LOL!!!! 5 minutes it is!!! ;-) Also instead of a 'button' to press... I hid a magnet, plastered into the wall... and inside a poo emoji toy, I put a door / window contact sensor!!!! The kids (and me!!!!) love tapping the poo toy on the wall to get the fan boost!!! ;-)
@jonhobday82982 ай бұрын
Does the internal part of the vent, the part you insert into the ceiling at 2:20, come with the extractor? Thanks!
@jparky19727 ай бұрын
Nice video and very well explained regarding the wiring. I'm sure I read somewhere that you shouldn't put extractor fan inlets and smoke detectors in the corners of rooms due to how air flows in a room.
@TheDIYGuy17 ай бұрын
👍 thanks, never had a problem myself with this position but I’d like to hear if anyone has.
@idi0tdetectioninprogress7 ай бұрын
Smoke detection should be 1M in from walls where possible and installed flat, as smoke rolls. Extract ventilation is sited more source specific, like over baths/toilets, in front of cooking areas etc.
@gwarski7 ай бұрын
By putting the valve in the corner you do restrict the air flow, however in this scenario the difference would be negligible
@Polyhive2 ай бұрын
What I would like advice on is where to source the outside vent with a one way flap that does not rattle in a wind??
@Joshoptimuscrime7 күн бұрын
I bought a MF100T a few weeks ago. It’s running at its maximum speed, the fan has approximately 400mm of duct either side, venting out of the gable end with a wind flap vent. The vent is directly over the shower (rainfall type) The suction is unbelievable I must admit however the bathroom is still very foggy when showering and moisture is still dripping from the ceiling, walls are still wet after a shower. I don’t know what more I can do, very annoying. I may install another fan but on the external wall and see if that helps.
@BarrrySpiersАй бұрын
I’ve just replaced our manrose MF100T after 7 years of use (it died gradually getting slower and slower and yes it was cleaned annually). They are great, quiet extractors, however, having tried all sorts of ducting the wind noise in our small ensuite is very loud. I would be interested in any advice to limit this noise, my 2 thoughts are: 1. Fit a different inlet grill in the ensuit, maybe a different design may cut down the wind noise? 2. Set the fan speed to med or low? However I love the volume of air this thing sucks out on high speed, it almost closes the door! 🤣 Grateful for any advice please…..👍
@christycullen25857 ай бұрын
Great video, I know how hard work is in attics, well explained
@TheDIYGuy17 ай бұрын
Thanks, it really was a tough one so thanks for acknowledging that.
@SmallEyeSpecimenHunterАй бұрын
Great video, would you be able to do a video on removing internal transom glass panels? Cheers
@copyandpastification23 күн бұрын
5:57 anybody knows what type of condensation trap is needed
@garyhowe4961Ай бұрын
With a tile vent in the roof above the bathroom ceiling what is the best way to have the ducting since it will in effect slope upwards to exit as opposed to down like in the soffit example in the video?
@humayunahmed49557 ай бұрын
These videos make me want to do so much work to my house now 😭
@MatC-l5cАй бұрын
Any recommendations for ventilation in a downstairs shower / toilet room without any direct access to the external wall - it’s adjusting a neighbouring property?
@steve63757 ай бұрын
I use medium hard rubber spacer standoffs to mount the fan motor. It makes a massive difference to the noise because the board you screw it on acts as a sound board and amplifies the vibration. Easily available from Amazon, etc. Don't know why Manrose don't supply them in the first place!
@Hypnot474 ай бұрын
I'm analising the possibilty of adding one of these on a kitchen floor with a 150 mm tube going up to a kitchen island balcony. Do you think it would work upside down? sucking the fumes from cooking straight to the floor and outside my house, maximum 1 meter distance tube?
@cham2-m4k3 ай бұрын
good video... i hope to know how to reduce or mitigate the noise and vibration arisen from the extract fan even though acoustic mat is placed below the fan?
@padymac1Ай бұрын
Hi great video once again I have the same in-line fan can you tell me where you got the inside ceiling vent from so I can get mine fitted the ones I have seen need screwing right on the edge of the hole and don’t have much length for the ducting to fix to many thanks .
@bowwave593 ай бұрын
Had one of these fan for the last 10 years. Because of the room size & large amount of steam in the room I’ve set the jumper on full speed & the timer keeps the fan on for 5 minutes after the bathroom light is turned off. I get up in the loft once a year to clean the fan . It can be detached from its mount so you don’t have to disconnect the pipes.
@Samirmasters6 күн бұрын
Would you be able to hear it in the bedrooms? Or any vibrations?
@trisknight9430Ай бұрын
Is it better to have the vent over the shower area we put an inline in to replace the ceiling fan but still getting mould patches but only in the shower area unfortunately room doesn’t have external window
@IAINoodle7 ай бұрын
Is it possible to do the same set up but to also have a humidistat that triggers the fan as well as the light switch and overrun feature?
@katus109Ай бұрын
Hi just wondering can you advise what you should do with the permanent live if you have an extractor that doesn’t have a timer …. I’ve replaced a broken timer extractor for one without but now it’s constantly on the bathroom switch doesn’t turn it off?
@itwillbenicewhenitsfinished5 ай бұрын
Absolutely brilliant video - thank you. About to do same myself. One thing I don't understand is why the chase out between the switch and the isolator? nothing seems to be running in the chase. I'm trying to work the runs out - am I right in thinking like the mock up; run everything up to the wago box in loft and run it out to fan and lights from there? I will need to do a chase like you to get the light swich cable into the loft but will it just go through the isolator switch back box but just using this as a path and making no connections here? Thank you so much again - great channel, Best wishes, James
@qkayani7 ай бұрын
Would having the vent above the shower not cause a cold draft coming down when showering , say if you don't put the lights on in winter? Would being slightly further from where you stand be better?
@samashevs7 ай бұрын
"inshulation" this vid was really helpful thanks!!
@TheDIYGuy17 ай бұрын
Glad it helped!
@DeanW-199028 күн бұрын
Hi mate if I have 2 en-suites and one main bathroom can I connect this to 3 bathroom switches ?
@gablan14687 ай бұрын
04:10 - may I ask what kind of wall (material) was that? You drilled it very fast.