⚠️ *Found this video super useful?* Buy Paul a coffee to say thanks: ☕ PayPal: www.paypal.me/TheEngineerinMindset
@bmeproductions59265 жыл бұрын
Thank you
@shithappens00093 жыл бұрын
what is the condensing temperature of co2 and evaporating temperature of ammonia in the cascade condenser?
@AllanTanabe3 жыл бұрын
Why some systems has Ammonia pump and some systems don't?
@laylow5975 жыл бұрын
I've been in the business for 22 years and this is by far the best e learning I have ever seen. Thank you keep up the good work.
@juniorbovilleakalegendary29934 жыл бұрын
Hey
@juniorbovilleakalegendary29934 жыл бұрын
I can get some help from u since u doing for 22 years
@abazism2 жыл бұрын
How much dose a technician makes in industrial refrigeration?
@vallexd59232 жыл бұрын
@@abazism basic salary in my country
@varrisprancisco7891 Жыл бұрын
I need your help, I want to be an AC technician. Do you want to help me
@AliMohammad-es4ek2 жыл бұрын
You will definitely be rewarded by God for this...as you are helping a lot there for free...Love you man
@tripplewhipper3 жыл бұрын
These have got to be the best laid out videos and explanations available. Thank you
@aubreyroche50803 жыл бұрын
Awesome... I am an Industrial Supervising Electrician. We work on all Electrical and Control for these systems, while also doing Everything else that is Industrial Electrical. Loved this Video !
@ApurvaKhartad Жыл бұрын
Very well explained. Thank you
@norbertopanes72627 ай бұрын
I had been in the business for 37years and i like this e-learning, Thank you keep up the great works.
@darshankuwar49146 жыл бұрын
Thanks eng. Mindset....this video helps me lot about my work......be proceed more video on this topic in detail to solve problem in industrial refrigeration.
@vegassasin7 ай бұрын
Ive been on a few of these projects in Aus. as a pipe welder. Its great to learn more about them as im normally hyper focused on my scope of works on site.
@201crunt66 күн бұрын
What metal was the pipe made out of?
@joshuastull7252 жыл бұрын
Would you consider tackling the absorption ammonia refrigeration system? I realize these are small scale but your delivery is so great, it would make my day:)
@CBKCUSTOM Жыл бұрын
I see u on facebook commenting about a post of screw compressor and then search it on yotube then i saw u again heehhe are you a mechanical engineer? Btw i am a 2nd year mechanical enginnering student. Take care always!!
@speciosa1465 жыл бұрын
This is fantastic, i love the smooth animation and easy explanations. I just found this channel and if your other videos are as good as this one ill be sticking around for a long time. Thank you so much for these awesome videos. P.s. Shouldnt there be a regulating valve on the cascade condenser?
@timothyjamieson12822 жыл бұрын
Agree, very well done and clear animation. I also will be watching a lot more. Thanks!
@kbhargav19854 ай бұрын
This is an excellent explainer video of the Industrial Refrigeration System. Thoroughly appreciate your efforts to share this knowledge with us industry folks!! :)
@Coltography6 жыл бұрын
Could you do a video on how purge units work for ammonia systems? Specifically the kind which condense using the suction vapour line and not a seperate refrigeration system.
@mohammeddanishsayed71425 ай бұрын
search how auto purger will work you will find
@KarmaxDK6 жыл бұрын
Good video, keep it up my man
@EngineeringMindset6 жыл бұрын
Thank you
@alexramos14352 жыл бұрын
First day doing industrial refrigeration. Worked on an ammonia chiller and this video just simplified all the shit that I saw today. I bled out the oil into a bucket and got a good whiff of that good ole ammonia. Smells like death.!
@Bushvvacker3 жыл бұрын
Great explanation... I have an alternate method to this that is way more efficient than a cascade. We have hit -112c with a single stage system and can get much lower. Patent Pending!
@ryanm72493 жыл бұрын
Is the system you have and are referring to an altra-low freezer?
@Bushvvacker3 жыл бұрын
@@ryanm7249 it can be used as an ultra-low freezer yes. We see it having a multitude of uses across many industries.
@dan4age2 жыл бұрын
Do you produce these systems yet?
@Bushvvacker2 жыл бұрын
@@dan4age We have been in production since 2020 with multiple working models currently in operation.
@201crunt66 күн бұрын
What is it?
@XsmokebreakX Жыл бұрын
Just started hvac this was extremely helpful
@vijithamuthugala18292 жыл бұрын
Awesome presentation ! . I found this while searching for Amonia system issues as I am having prolong issue in my Ammonia compressor . Grateful if you could support me to solve it. We have a two stage ammonia compressor connected to Blast freezer of -40 C . At start it perform well and while room temperature down to -30 C Compressor oil pressure reduces gradually below to the set point ( 1,5 bar) and shuts down . All the components were checked , replaced ( bearing , pump , filters , oil etc ) . nothing didn't solve the issue. But one day in a test run suddenly , the machine picked up the oil pressure and run as normal. It continuously ran for two weeks without problem and all of a sudden again the same issue occurred . Now we are helpless . If anybody can support us, it is very much appreciated. !!
@LC-qi5ff Жыл бұрын
How did it go? Please tell us
@allanweitman2 жыл бұрын
I'm currently taking my power engineering level 5 and this is super helpful for understanding when you are just learning. The videos they have with the course are so boring/terrible/old. I'm so glad I found these
@stevelamperta8653 жыл бұрын
The regulator valve and expansion valve are almost the same , the only difference is the expansion valve has much better and consistent adjustment for the very much important amount of liquid ammonia going into the evaporator . The regulator valve controls the pressure differential between the condenser and receiver . the head pressure runs around 125 an 150lbs , an the receiver runs at 75lbs pressure differentials are key , as that's how the system works. I was a manager of several companies with ammonia refrigeration systems .
@pradnyashankardas6435 Жыл бұрын
Yes great, Pressure difference is the key
@thomassim5600 Жыл бұрын
What will happen if there's a high pressure differential
@brandonbarnard36605 жыл бұрын
Very good video, doesnt get no better than that for simplicity.
@alnonymous93615 жыл бұрын
slight error... the cascade condenser is the evaporator of the high temp circuit and the condenser of the low temp circuit. At 8:00 you said it backwards.
@jamiyapolangi45374 жыл бұрын
Hello, can i message you I would like to know how Ice plant works I'm planning to assemble on my own thank you hope you notice me.
@yl71083 жыл бұрын
Good point! I was going to point that out too.
@Sachinkumar-hy3ti4 жыл бұрын
Ammonia refrigeration is my final year projects topic ..✌️
@strikejones27715 жыл бұрын
Great video to refresh yourself from time to time.
@gregorystewart48873 жыл бұрын
thank you for the video, I'm new to ammonia refrigeration and found this help full we have
@refliconinc.official51402 жыл бұрын
Good video, thanks engineering mindset team
@rishuraj88243 жыл бұрын
Excellent ...just made it so simple
@raymondmosher55834 жыл бұрын
you always have the best tech videos
@abhijeetlage81454 жыл бұрын
man....u are a saviour...
@DavidFMayerPhD5 жыл бұрын
Questions: 1. What material is used to contain the ammonia? 2. How do you keep the ammonia dry? 3. Why do you use isenthalpic expansion instead of isentropic expansion which should be more efficient, at least, in principle? 4. What kind of seals are used on the compressors to keep the ammonia from contact with the motors?
@juansalazar43255 жыл бұрын
1. You can contain ammonia in tanks, while pressurized. 2. The only way the ammonia get wet is if there is a leak and air gets in, this happens in cases in which you are working in vacuum. To vent out the air, you use an air purger. 3. For this you need to understand the refrigeration cycle with a pressure vs enthalpy chart. In a sense, you need to keep the enthalpy in the same level after it passes through the condenser. 4. The motor is connected to the compressor through the shaft. The compressor would have a shaft seal to keep the ammonia within the compressor. There are videos on how a shaft seal works. Hope it helps!
@DavidFMayerPhD5 жыл бұрын
@@juansalazar4325 Clarification: You wrote: "You can contain ammonia in tanks" What material are the tanks made of? "You need to keep the enthalpy in the same level after it passes through the condenser." Why?
@CoastalSphinx4 жыл бұрын
@@DavidFMayerPhD Ammonia is contained in steel. Steel is adequate and inexpensive. Never use copper or copper alloy such as brass or bronze - ammonia will corrode them very rapidly. Isentropic expansion is difficult. A machine is needed to extract work. The fluid is a gas/liquid mixture so a controlled expansion is even more difficult. And the efficiency loss from the isenthalpic expansion is small because the amount of expansion is small, most of the expansion is due to isothermal evaporation. So even though isentropic expansion is best in theory, practical limits favor isenthalpic expansion.
@entity6966 Жыл бұрын
1. stainless steel and black iron pipe 2. using purgers and to take out non condensable as well as getting anhydrous ammonia when you first fill up. 3. i dont know tbh 4. its a carbon and material that sits on the shaft of the compressor. called the shaft seal that prevents push back. it usually sits in oil to prevent any leakage and they get replaced every so often depending on the wear they get. usually there isnt any direct contact what so ever with the motors unless theres a huge problem.
@user-ex6uk6ye3o4 жыл бұрын
Thank you sooooooo much ❤️ this video saved my life
@temporalosm4 жыл бұрын
I love basically anything industrial :P industrial style stuff looks so good :P
@johnnyparterlee70662 жыл бұрын
Beyond awesome, Cheers!!
@kylenorton155 жыл бұрын
One key factor that was forgotten is that ammonia is highly corrosive to anything containing water, including your skin. Copper also can’t be used on ammonia systems at all
@bigkirbyhj6662 жыл бұрын
How about galvanized steel?
@entity6966 Жыл бұрын
@@bigkirbyhj666 i dont know anyone that uses galvanized pipe. however using stainless or just black iron is fine.
@ggproductions8434 Жыл бұрын
Ammonia absorbs water so it dehydrates your skin.
@kuluk6254 Жыл бұрын
Can't use galvanize steel, silver,gold, copper n brass
@mutiur73964 ай бұрын
But I have heard it is used in volatile pH control of water system for corrosion prevention
@passionateengineer044 жыл бұрын
Good work, i will share video on my channel about industrial refrigeration system that are currently installed in our factory.
@Fakhrealammm6 жыл бұрын
Always great. Upload a detailed video please.
@yowjoral84796 жыл бұрын
thank you for this vid. im gathering ideas for LIQUID AMMONIA :) keep it up!
@JohnSmith-xk8rr4 жыл бұрын
NH3 systems require a T-machinary room classification. Without proper emergency pressure release systems, diffusion and fire suppression the risk of a toxic explosion is too high and therefore only certified techs can make physical changes to the system and certified RO/PE's can operate it. If you want to experiment with refrigeration, I'd recommend using something inert and learn about corrosion, piping codes first. I have personally rigged a commercial AC to the side of my house and use the heat in my greenhouse. It can take litres of water out of the air and cool my entire place below 60 degrees. The waste heat can become it's own project. If this field interests you there's extremely good jobs in heavy industry. I'd say it is less of a career because you will always be training and working on new systems unless you find a chief plant operations position but eventually you'll want a bigger system to operate as you gain more firing time and experiance.
@gregorymalchuk2723 жыл бұрын
@@JohnSmith-xk8rr Do You have it rigged as a reversible heat pump, or did you just place a condenser in the greenhouse? There are some circumstances where you may need to cool a greenhouse too. Is the air conditioner new or an old unit removed from a residential home? What refrigerant does it use?
@stevelamperta8653 жыл бұрын
The expansion valve and the regulating valve you have backwards ! The expansion valve goes in between the evap and ammonia pump . And normally a single stage system doesn't use ammonia pumps , they run off the receiver pressure . the regulator valve belongs in between the condensor and receiver to put a diff of head pressure of around 150lbs to 75lbs receiver pressure.
@bradvincet18483 жыл бұрын
Thanks for clearing that up, I was going to ask the same question. If they're going to make informational videos they need to get the facts straight.
@entity6966 Жыл бұрын
they can and do have pumps. you're thinking of a single stage system with control pressure receiver and dump tanks, which have no pumps but instead rely on a set pressure of ammonia sitting in a vessel to be fed into a tank and then pushed by hot gas to the evaps.
@henrybartlett19864 жыл бұрын
Excellent , as usual.
@insanity2304 жыл бұрын
Great videos very educational and appreciated
@methuselahbwalya99812 жыл бұрын
Thanks for making it easy to understand. Been working on an NH3 plant Ref for 11 years . NH3 as our primary & H20 / Glycol as secondary Ref . Thank you
@mathankumarn19346 жыл бұрын
great video, Sir what are the factor to be considered for a water chiller design and how to select compressor and condenser for those design
@thomasalbert6634 Жыл бұрын
Do you have an ammonia refrigeration example similar to the "Design a refrigeration system" video with example calcs? Not sure how to deal with the liquid/vapor mixture coming out of the evaporator. Thanks. These are all great videos!
@lifeinthearclane62406 жыл бұрын
Love the videos keep em coming
@moveit7074 жыл бұрын
So informative thanks
@alexciocca44512 жыл бұрын
I remember ammonia refrigerators in the kitchen powered by a small gas flame
@miribejko62934 жыл бұрын
Thanks for the vid.really useful and informing.
@Lukelins13 жыл бұрын
I was on an ammonia hazmat team. We did have a leak that I discovered in the beef fabrication department while working food safety.
@liogonzalez88134 жыл бұрын
Great video!
@isaiahisrael421 Жыл бұрын
What is the purpose of the EQ pipe in an ammonia refrigeration system?
@titusnunumbal21862 жыл бұрын
Thanks
@Alienspecies6352 жыл бұрын
I’ve always called the compressor the heart of the system. Should have been an engineer.
@kaustubhsawantdesai75866 жыл бұрын
Hello engineering mindsets team I have a question regarding the industrial video with ammonia as refrigerant. In the video it is shown that cascade intercooler or heat exchanger is used to maximize the refrigerating effect. How I can use the same in 60TR block ice ammonia ice plant where we produce the ice for marine products so that I can increase the refrigeration cycle more efficient and decrease the time of production.
@watsonwolfe4 жыл бұрын
Outstanding!
@SoumenMondal-hq3gt3 ай бұрын
Please explain intercooler working process with animation
@erkyserfarooq73653 жыл бұрын
Sub titles are hindering the illustrations, modify it,or keep margin for it ...rest best technical e learning forum, keep it up
@EngineeringMindset3 жыл бұрын
Subtitles aren't fixed, you can turn them on and off or move them on screen
@thomassim5600 Жыл бұрын
Can u share more about the pressure equaliser pls
@STEINYY4 жыл бұрын
god bless you sir! god bless
@Timeshallpasss4 жыл бұрын
Greatly done 🙏🌹
@panhaven7394 жыл бұрын
Thanks for video
@changvillacampa85134 жыл бұрын
i like the engineering mindset and thank you god bless
@pervaiziqbal-jw6is Жыл бұрын
Thanks sir very good video nice 🇵🇰
@eng-vf2gh5 ай бұрын
Dear sir nice video . But i want to know when calculate the effencity of refrigeration cycle we divide out put by input . And we consider only workdone by the compressor and not consider work done by condensor fan as we are paying charges to operate electrical energy
@roflex23 жыл бұрын
Can you do a video on the old propane fridges
@coldude2559 Жыл бұрын
Great 👍
@BayusjayaHVACR4 жыл бұрын
Hy do you have video how ultra low refrigerator work im from Indonesia
@Praveen2715 жыл бұрын
Good explanation..!!
@xer00style Жыл бұрын
Thanks a lot for sharing this contect in the way you does. Great to have a channel wi +2M Suscribers and sharing knowledge as it should be.
@resurgensix3 жыл бұрын
Love it!
@joshuabaughn3734 Жыл бұрын
2:12 You're forgetting that when Anhydrous ammonia reacts with water, it generates heat. At certain storage densities, this is bad… you get a runaway reaction which leads to a massive explosion. This is what happened in Beirut.
@maddog2557 Жыл бұрын
Ammonium nitrate, NH₄NO₃, solid, fertilizer, was Beirut. This vid is about Anhydrous ammonia, NH3, a gas, that can also be sprayed into the soil as a fertilizer and also used as a refrigerant.
@JayeshPatel-sf5er5 жыл бұрын
Superb channel
@peanutpotion3 жыл бұрын
fantastic
@tsmspace6 жыл бұрын
BUT, CAN i have a portable "cooling" unit that generates enough power from the heat to charge my devices.???
@realvanman15 жыл бұрын
7:59 Cascade condenser, Acts as a condenser for the LOW temperature circuit, and an evaporator for the HIGH temperature circuit. Yes?
@JDHolmes1315 жыл бұрын
Yes
@dangoldbach65705 жыл бұрын
Yes, correct. He stated it backwards in the vid
@guillermohermosa17174 ай бұрын
Amonia is the best, the cheaper, can reach as the temp required, one thing is not good it is toxic or poisonous and hazardous element but useful in some otherway..
@delas88215 жыл бұрын
Thanks for the information..👍
@tobiasfate94222 ай бұрын
Hello sir, i would like to clarify and ask. The equalizing line's purpose is to equalize the pressure between the compressor outlet/condenser inlet with the ammonia receiver to allow the liquid refrigerant flow towards outside the condenser outlet more easily. Then, if there were no equalizing line existing between those two points, would there be an overflow, followed by back flow? Then the equalizing line's another purpose is to prevent the liquid refrigerant flowing back inside the condenser. Please correct me if I am wrong sir, thank you very much.
@NovelMehari-u4b Жыл бұрын
I need can you help mi joened with the campeni do you entersted
@bartosik3213 жыл бұрын
Industrial refrigeration and its concequences
@joshroberts2433 ай бұрын
Question, you mention at the end in a cascade system that it sometimes uses 2 different refrigerants, allowing you to use less ammonia. But you said a couple times in the video the refrigerants never make cntact with air or water ad always sealed. That makes this a closed loop system and the refrigerants shouldnt be consumed no?
@ralphnabozny84945 жыл бұрын
this is very good
@stevelamperta8653 жыл бұрын
Don't need the liquid separator either . This system is set up wrong with equipment it doesn't even need ! I have built a few engine rooms in my time. I worked with a guy who trained me and we called him the ammonia God ! lol Really smart man .
@EngineeringMindset3 жыл бұрын
This is a simplified version of a system, to understand the basic operation through animation. It is not an actual system. The system components are typical.
@frixux2 жыл бұрын
is any good book about it ?
@alroy123455 жыл бұрын
Anything on dissecant dehumidifiers??
@bosonglin74625 жыл бұрын
Thx!
@AfjalKhan-nh8hb4 жыл бұрын
Thanks for information but Small request This video makeing in Hindi please please please 🙏🙏🙏 I AM from India 🇮🇳🇮🇳
@EngineeringMindset2 жыл бұрын
Thank you, do you know we also have a Hindi channel? kzbin.info/door/g4k338hz9U8jnD5SXPO5jQ
@mahmoudabdelhamid4695 Жыл бұрын
What is the difference between the compressor rotating 3000 rpm/min? And 1500 rpm/min?
@melvindownload81783 жыл бұрын
sino nandito dahil sa ammonia leak sa Navotas? 👇
@spnenter64233 жыл бұрын
Best
@antoniomiguelamoroscrippa84675 жыл бұрын
Great!!!!!. Can you put subtitle in spanish,please?. Thank you so much.
@EngineeringMindset4 жыл бұрын
Española aqui: kzbin.info/www/bejne/bXunnql6r8dogpo
@ganeshsaren84264 жыл бұрын
Good
@SoumenMondal-hq3gt3 ай бұрын
Economiser is a sub cooler and intercooler is different part
@geofferyromany46342 жыл бұрын
Can LH2 be used in the exact saame way? If not how dan it work? Thx
@fivespeed24 жыл бұрын
So the intercooler is calling for the liquid from the HPR?
@universalservicetechust35783 жыл бұрын
Not rocket science but still Pretty cool 😎
@michael331325 жыл бұрын
Muy buena imformacion ouede incluir sudtitulos en español
@EngineeringMindset4 жыл бұрын
Española aqui: kzbin.info/www/bejne/bXunnql6r8dogpo
@stephansaintremy43713 жыл бұрын
what's the difference between a liquid separator and liquid accumulator?
@entity6966 Жыл бұрын
the accumulator just holds liquid and gets pushed out by the discharge pressure of the EQ line. A separator has liquid that has been pushed through from the accumulator and then it is sucked on by a compressor from the top. liquid stays at the bottom and the vapors get pulled through by the suction.
@toyinorodare40725 жыл бұрын
Please where can I get practical training on INDUSTRIAL REFRIGERATION please help me out.
@everettamador98853 жыл бұрын
Ammonia has the highest Caloric Absorption
@mercnathanielcavada33615 жыл бұрын
The liquid separator tank, is this thermal insulated? Please reply. Thank you
@kasslerify4 жыл бұрын
yes it is. Everything after the expansion valve coming after the receiver is insulated.