"Ah, yes, well, you forgot that your train has a buffet car, so you're dead."
@bussesandtrains1218 Жыл бұрын
mild design oversight
@fetchstixRHD Жыл бұрын
Call that a taste of death...
@PottersVideos29 ай бұрын
RIP
@390h8er4 жыл бұрын
Were drivers expected to change a fuse as soon as it had blown, or wait until a suitable time/journeys end?
@roberthaydon797317 күн бұрын
3:35ish Why is the cab light on again? How is the cab light on again?
@roberthaydon797317 күн бұрын
What I mean is:- Unless the cab light is battery powered, possibly charged by the third rail supply but otherwise a separate electrical system, how is this test supposed to reassure me or anybody else?
@jontownsend80904 жыл бұрын
People back then had more respect for danger than they do today, due to health & safety. There comes a point when too much h&s leads to complacency. Back in the BR days, they may have done things differently, but all staff respected the dangers.
@alfwedarf77644 жыл бұрын
Exactly, and all of the practices in this film are safe. When the narrator said that it was most important to absolutely ensure that the electrical loads in the train were isolated by means of the main isolator, that ALL shoes are firmly off the juice and firmly held by the paddles, means that there is no risk of explosion during fuse replacement. People had more common sense back then.
@manekdubash50223 жыл бұрын
Not convinced the death & injury rates then and now would support your contention.
@nigellewis46864 жыл бұрын
Do modern trains have circuit breakers instead
@ElliottHurst4 жыл бұрын
I believe they still have shoe fuses
@fetchstixRHD3 жыл бұрын
@@ElliottHurst: At least the Electrostars still do have the shoe fuses - they're quite visible (either covered with the electrical warning [Southeastern] or with the warning above the fuse [Southern]). Can't remember whether the Desiros and Aventras had them or not, but I'd think they do?
@Sarahbryson3212 жыл бұрын
@@fetchstixRHD the 250/1 have them the /2s (i hate them) /3s and /4s could be retrofitted
@srfurley Жыл бұрын
On the class 71 when the pantograph was in contact with a live overhead wire were the shoes live? How did things work on the old 1200V side contact system on the Manchester to Bury line? I remember that these units carried a short circuiting bar which was a different design with a heavy metal ball on the end of the handle. Was there a type of shoe paddle for use with Regis system? Could any work be done on these units without the traction current being turned off?
@danwoodhouse92906 жыл бұрын
MONOCHROME?
@marcuspotter55905 жыл бұрын
This is an old video from 1993.
@MannyAntipov2 жыл бұрын
@WhiteShadow2k1 This is the late 80s and many training videos, even by Network Southeast themselves, were already using colour. What gives?!
@poker_cat5 ай бұрын
@@MannyAntipov the actual vhs tape is probably warn out
@louiejonesponation3 жыл бұрын
Still in Black and White? That was in late 1980s and is in black and white?!
@CosgroveNotts5 жыл бұрын
Can't believe they are doing this. Definitely a no no in any other job
@marcuspotter55905 жыл бұрын
They don't anymore, this is an old video from back in 1993. They did things differently back then!
@CosgroveNotts4 жыл бұрын
I wouldn't trust any kind of driver to change a house fuse.
@srfurley Жыл бұрын
Ok, so yo paddle up all of the shoes and check that there is no power to the unit. But what happens if something knocks out the paddles from under one shoe? Say an animal gunning alongside the track, or some object or damaged shoe gear sticking out from a train passing on the other line. Wouldn’t it have been safer if means had been provided for the normally live parts to be bonded to the running rails to prevent them becoming live unintentionally?
@marcuspotter55905 жыл бұрын
Many years ago my father was an electrician's mate, he would never attempt any of the stunts depicted in this video.
@cjmillsnun10 ай бұрын
They aren't stunts, and no he wouldn't because he wouldn't touch 750v DC electrics.
@vincitveritas38723 жыл бұрын
Need to get rid of third rail.
@frostycola423 жыл бұрын
nse ran out of money
@g2macs4 жыл бұрын
The ribbon fuse is a god-awful design, just pure laziness not to retrofit a trip circuit or a ceramic fuse 'plug' that keeps the driver safe.
@philaypeephilippotter65324 жыл бұрын
*g2macs* If you mean the large copper ribbon fuses above the collector shoe on the bogie the design is deliberate. These fuses wouldn't usually blow as the sub-station circuit-breaker would normally go first. The current they routinely handled was over 1,000 amps at about 750 volts.
@ericssmith20142 жыл бұрын
@@philaypeephilippotter6532 And here we are being told how to change one with our bare hands in the rain, hoping that we've remembered how to flip the right switches.