Although the 7.6 has 3 MPPTs. Isn't it possible for the inverter to hold 6 strings in total? 2 strings per MPPT?
@Tigo_Flex_MLPE18 күн бұрын
It is possible but not recommended. The inverter will expect that it is connected to 3 different strings, and its MPPT will behave as such. It won't know if there are other parallel strings. The MPPT won't be able to adequately track the correct voltages from the combined strings. There could be production losses. Also, since the strings are combined, troubleshooting arc or ground faults will be much more difficult. You should verify that you do not exceed the current limits of the inverter. This behavior is true of most PV inverters.
@geekplaza66892 ай бұрын
Has zero export? For grid tied?
@Tigo_Flex_MLPE2 ай бұрын
We sure do! The zero export settings can be changed using the Tigo EI app and navigating to the Energy Meter settings page.
@imacmacnerd7 ай бұрын
Do you have to have batteries to use this inverter initially? Or can you add them later after installation?
@Tigo_Flex_MLPE7 ай бұрын
Great question! You can absolutely add the batteries later, although you would need to also add the automatic transfer switch.
@SupportNoob4 ай бұрын
These work with Yilink batteries? the 11kw model looks very promising for what I need, I assume the 11kw are both using either grid power or battery/solar only no? Mine caps at 10kw using grid power and around 8kw using solar/batteries only
@Tigo_Flex_MLPE3 ай бұрын
The Tigo EI inverters may be used with AC coupled batteries. Contact our support team for assistance. se@tigoenergy.com
@earthenergyhex8 ай бұрын
I didnt know Tigo sold inverters. I have been looking to replace my Schneider Electric System. I am going to take a hard look into Tigo
@Waldoe16 Жыл бұрын
Very nice! Would like to see the full installation/comissioning(ATS/inverter/battery). When are the All-in-one systems coming to the USA? The european versions look like a nice option too.
@Tigo_Flex_MLPE Жыл бұрын
Yes, the European stack is pretty slick. We have some new things on the horizon for the US market. Stay tuned!
@DarceyDockstader Жыл бұрын
Our power company is asking that we install our rapid shutdown buttons inside of a bubble cover. Is there an option for this with tigos rapid shut down button?
@Tigo_Flex_MLPE Жыл бұрын
We leave equipment selection up to the installer. We do not provide an outdoor rated enclosure for a rapid shutdown initiator.