Toilet Ventilation Design | Toilet Exhaust CFM Calculation in Urdu

  Рет қаралды 6,558

Tanweer Ahmed

Tanweer Ahmed

Күн бұрын

Welcome to our comprehensive Urdu tutorial on toilet ventilation design and toilet exhaust CFM calculation. In this video, I will guide you through the process of creating an effective ventilation system for your bathroom, specifically focusing on the toilet area. Proper ventilation is crucial for maintaining good air quality, reducing odors, and preventing the buildup of moisture and mold. I explain the key principles and factors involved in ASHRAE 62.1 toilet exhaust air calculation, providing you with a clear understanding of the process.
Throughout the video, we will explain the key principles of toilet ventilation design, including the importance of airflow. Additionally, we will delve into the concept of CFM (Cubic Feet per Minute) calculation, which helps determine the appropriate fan capacity for your toilet exhaust.
Whether you're a homeowner, contractor, or DIY enthusiast, this tutorial will equip you with the knowledge and techniques needed to optimize your toilet ventilation system. Join us as we break down the process step-by-step, providing practical tips and insights along the way.
You can watch more of the followingTanweer Ahmed's videos:
1. How to measure HVAC duct sheets?
Video's Link: • How to measurement HVA...
2. How to Prepare Measurement Sheet for Chilled Water Pipes
Video's Link: • How to Prepare Measure...
3. What is BOQ | How to Prepare BOQ | Rate Analysis of Bill of Quantity
Video's Link: • What is BOQ | How to P...
4. How to take off duct quantities from drawings? MEP quantity surveying
Video's Link: • How to take off duct q...
5. Project Construction Drawings types
Video's Link: • Project Construction D...
6. Project Closeout Requirements | Part-1
Video's Link: • Project Closeout Requi...
7. Project Closeout Requirements | Part-2
Video's Link: • Project Closeout Requi...
8. Construction Sequence of Projects | Section-1
Video's Link: • Construction Sequence ...
9. Construction Sequence of Projects | Section-2
Video's Link: • Construction Sequence ...
10. Construction Sequence of Projects | Section-3
Video's Link: • Construction Sequence ...
11. How to Prepare Interim Payment Certificate (IPC)
Video's Link: • How to Prepare Interim...
12. How to Prepare BOQ for HVAC Works in Urdu | Rate Analysis of Bill of Quantity
Video's Link: • How to Prepare BOQ for...
13. HVAC Basics: Air Changes per Hour and Calculating CFM of a Room
Video's Link: • HVAC Basics: Air Chang...
14. ASHRAE 62.1 Fresh Air Calculation Explained | HVAC Ventilation
Video's Link: • Fresh Air Calculation ...
#TanweerAhmed #hvac #mep #toilet #exhaust #air #calculation #cfm #ventilation #design #tutorial #urdu
= YOU CAN FOLLOW ME ON SOCIAL MEDIA =
LINKEDIN: / tanweer-ahmed-00142631
TELEGRAM GROUP: t.me/hvacmepenggg
INSTAGRAM: / tanweersethar
KZbin: / tanweerahmed
Disclaimer:
Tanweer Ahmed’s videos are intended solely for educational purposes, aiming to assist junior engineers and technical individuals in enhancing their comprehension of HVAC and MEP engineering basics. The information provided is based on personal experiences and research. It is advisable to consult qualified professionals or adhere to standards before implementing any techniques discussed. Please note that I cannot assure the accuracy or appropriateness of the information presented for your specific situation. Viewers are advised to watch at their own discretion, understanding that I cannot be held responsible for any damages or losses that may occur. Any response does not constitute legal or professional engineering advice. Seeking the advice of a qualified professional specific to your particular application is recommended.
Thank you for watching, and I hope you find the content helpful.

Пікірлер: 55
@ahmedpasha1207
@ahmedpasha1207 Жыл бұрын
Tanvir Bhai K liye Dil Se dua Allah Apko Aur Kamyab kare Bahot helpful hain apke videos
@TanweerAhmed
@TanweerAhmed Жыл бұрын
JazakaAllah
@mdshadman7596
@mdshadman7596 Жыл бұрын
Amazing explanation in very easy way…. Thanks a lot
@TanweerAhmed
@TanweerAhmed Жыл бұрын
JazakaAllah
@shahidansari9139
@shahidansari9139 Жыл бұрын
Very informative video. Pls continue as a series for cleanroom having different classes.
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Thank you
@mdshahidhussain5698
@mdshahidhussain5698 6 ай бұрын
Very helpful ❤
@TanweerAhmed
@TanweerAhmed 6 ай бұрын
JazakaAllah
@muhammadfarazkhansu0096
@muhammadfarazkhansu0096 Жыл бұрын
Really appreciate your help ❤️
@TanweerAhmed
@TanweerAhmed Жыл бұрын
My pleasure 😊, Jazaka'Allah
@mohammedriyaz223
@mohammedriyaz223 Жыл бұрын
Amazing topic sir ,,,,,
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Thank you
@Sohail_SKS
@Sohail_SKS Жыл бұрын
Superb sir Ji
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Jazaka'Allah
@nizamuddinz4392
@nizamuddinz4392 9 ай бұрын
could you pls make video on, how to select the duct gauges /THICKNESS FOR - SAD, RAD, FAD, EAD? ON WHAT BASIS WE NEED TO SELECT,
@TanweerAhmed
@TanweerAhmed 9 ай бұрын
Insha'Allah
@faridkhan-mf5xg
@faridkhan-mf5xg Жыл бұрын
❤Mashallah sir thank you
@TanweerAhmed
@TanweerAhmed Жыл бұрын
JazakaAllah
@faridkhan-mf5xg
@faridkhan-mf5xg Жыл бұрын
@@TanweerAhmed sir ap se request ki plumbing standard pe ik detail vedio banwo
@pakistanimanitehadinsaaf.4478
@pakistanimanitehadinsaaf.4478 Жыл бұрын
Good Job …
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Thank you
@nizamuddinz4392
@nizamuddinz4392 9 ай бұрын
MAKE VIDEO ON COLD STORAGE DESIGN - FREEZER, CHILLER
@TanweerAhmed
@TanweerAhmed 9 ай бұрын
I have no experience about it
@thepurposeofmyexistence2511
@thepurposeofmyexistence2511 Жыл бұрын
Nice video sir , but can we have video on sizing of expansion tank and chemical dosing unit , for chilled water system , i mean can y explain in one layout chilled water syatem such that where we will connect make water line , where we connect Expansion tank line , chemical doing line , air seperator line in chilled water system , and explain how to we start doing commissioning of this system from where we 1st inject water to the system , and do we do hydrostatic test , on what pressure ,, I will be glad sir if y explian it
@thepurposeofmyexistence2511
@thepurposeofmyexistence2511 Жыл бұрын
Also dear sir , asper nfpa 92 for smoke management system , when is the criteria to install smoke extraction system in the building , I mean is there any specific ht of building or area that building should have this system.
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Ok noted
@TanweerAhmed
@TanweerAhmed Жыл бұрын
I will work on these topics, time by time
@thepurposeofmyexistence2511
@thepurposeofmyexistence2511 Жыл бұрын
@@TanweerAhmed thank y sir , جزاك اللة خير
@nawabkamran5541
@nawabkamran5541 Жыл бұрын
Sir plumbing mein invert level calculation bylaye please
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Invert is lower level of pipe or manhole
@vijaybajaj401
@vijaybajaj401 Жыл бұрын
Tanveer I always prefer to give fresh air Nd exhaust fans in top end offices yes ACH m taking 12 for exhaust and keeping toilet always under negetive pressure our NBC is very very clear about this
@TanweerAhmed
@TanweerAhmed Жыл бұрын
🆗 👍
@saiyedali8329
@saiyedali8329 Жыл бұрын
Assalamualaikum sir ji CooldStorage ki details video se hame jankari dijiye please
@TanweerAhmed
@TanweerAhmed Жыл бұрын
W.salam, ok noted
@SaifAli-is9hb
@SaifAli-is9hb 8 ай бұрын
Ser ji ye ventilation ki duct design kitne velocity or kitne friction loss per karege aur grill and exhaust diffuser ko design krne k liye kitni velocity per lete h
@TanweerAhmed
@TanweerAhmed 8 ай бұрын
Watch my duct designing videos
@jamsheerali7229
@jamsheerali7229 11 ай бұрын
Thanks for this video, if this toilet is part of commercial or industrial building, how much cfm supply cooling need to provide?
@TanweerAhmed
@TanweerAhmed 11 ай бұрын
Welcome
@jamsheerali7229
@jamsheerali7229 11 ай бұрын
Sir .. please need ur answer? Can v give supply air to toilet as per ashrae
@nizamuddinz4392
@nizamuddinz4392 6 ай бұрын
Thanks for sharing information, there is a porto cabin trailer of size 12 mtr x 4mtr. In this 6wc and 12 shower, 7 lavatory. Wc and shower are separate and each has cubical partition, partition wall not touch with ceiling. In this case should i need to calculate 70cfm per wc and open area by 1cfm/ft. How about shower area exhaust per fixture or cfm/ft? Also this space is air conditioned by mini split unit.
@TanweerAhmed
@TanweerAhmed 6 ай бұрын
Review the ASHRAE standard's table for all different locations
@engr.aamirhanif961
@engr.aamirhanif961 Жыл бұрын
Thanks for your videos. It’s really helping me brother. I would like to ask “where can i get ASHAREA standards book for these ventilation systems”?
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Share email or join my Telegram group "HVAC|MEP Engineering"
@sarowarkabir974
@sarowarkabir974 Жыл бұрын
Make kitchen room ventilation design
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Ok noted
@akkivlogs3321
@akkivlogs3321 Жыл бұрын
Basement sump calculation
@TanweerAhmed
@TanweerAhmed Жыл бұрын
Ok noted
@taqirkan7712
@taqirkan7712 Жыл бұрын
Assalam O Allikum Tanveer Bhai...how can we calculate cfm for janitorial area/changing rooms associated with the washrooms? Thanks
@TanweerAhmed
@TanweerAhmed Жыл бұрын
W.Salam, As per ASHREA 62.1 Janitor closets, trash rooms, recycling is Exhaust Rate 1 cfm/ft2 and further review standard
@nizamuddinz4392
@nizamuddinz4392 6 ай бұрын
How to calculate heat load in washing area (WC, Shower, Lavatory)
@TanweerAhmed
@TanweerAhmed 6 ай бұрын
Do you want to air conditioning in Toilet?
@nizamuddinz4392
@nizamuddinz4392 6 ай бұрын
Yes, it's US Army Project.
@TanweerAhmed
@TanweerAhmed 6 ай бұрын
Heat load calculation is same process as you calculate in other areas
@nizamuddinz4392
@nizamuddinz4392 6 ай бұрын
Thanks for sharing information, there is a porto cabin trailer of size 12 mtr x 4mtr. In this 6wc and 12 shower, 7 lavatory. Wc and shower are separate and each has cubical partition, partition wall not touch with ceiling. In this case should i need to calculate 70cfm per wc and open area by 1cfm/ft. How about shower area exhaust per fixture or cfm/ft? Also this space is air conditioned by mini split unit.
@TanweerAhmed
@TanweerAhmed 6 ай бұрын
Check the table in ASHRAE standard for further details
Люблю детей 💕💕💕🥰 #aminkavitaminka #aminokka #miminka #дети
00:24
Аминка Витаминка
Рет қаралды 1,3 МЛН
SCHOOLBOY. Мама флексит 🫣👩🏻
00:41
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 6 МЛН
Public Restroom Exhaust Air CFM Calculation
20:01
HVAC Easy Math
Рет қаралды 320
CFM of a Room || ACPH, CFM,CMM,CMH || Vedio by Learn With Mir
5:24
Learn With Mir
Рет қаралды 57 М.
HVAC Ventilation Part 4 - Exhaust Air Calculation (ASHRAE 62.1)
5:39
HVAC SIMPLIFIED
Рет қаралды 22 М.
Mitsubishi HVAC At My House - Full System Tour
24:49
Matt Risinger
Рет қаралды 385 М.
HVAC Ventilation Part 1&2 - Fresh Air & Exhaust Air (ASHRAE 62.1)
9:40