ID, AR, NCS PART 2 IGEM G 11 QUIZ, Gas unsafe situations procedure what gas engineers need to know

  Рет қаралды 22,989

Tomkat Gas Training

Tomkat Gas Training

Күн бұрын

Пікірлер: 72
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
kzbin.info/www/bejne/iZK9hoxqm81kZq8 Link for part 1 if you haven’t seen it 👍🏻
@prsheating
@prsheating 3 жыл бұрын
Excellent very helpful mate...been a Gas engineer for over 35 years...your ironing out these grey areas.
@Tony-sr7vq
@Tony-sr7vq Жыл бұрын
Hi Derek just like to say a big thank you for all your time that you do it is a big help. Thank you
@msuk5957
@msuk5957 2 жыл бұрын
Thank you Derek , Mohamed Hassan
@patrickoregan7102
@patrickoregan7102 2 жыл бұрын
Great videos,thanks Derek , a big help with up and coming ACS 👍
@pbernard6313
@pbernard6313 5 ай бұрын
Thanks, very good teaching
@mohammednadeem7274
@mohammednadeem7274 3 жыл бұрын
Excellent video Derek on these unsafe situations. Its good to know what you will come across on jobs onsite. Thanks.👌👍👍😁😀
@williamhoughton1484
@williamhoughton1484 2 жыл бұрын
Well done Derek , Keep them coming . It brings me up to speed!🤪
@azimkhan9862
@azimkhan9862 3 жыл бұрын
Fantastic video Derek, highly appreciated the best videos out there for unsafe situations are your videos part 1 and 2. Hopefully part 3 soon 😋
@aphroditenajad2603
@aphroditenajad2603 2 жыл бұрын
Fantastic, Thank you, I love this questions and answer with explanations! Well done !
@AnEyeScream
@AnEyeScream 2 жыл бұрын
Thank you, Nikola Ditsov
@Neutron66
@Neutron66 2 жыл бұрын
Ever since PME (protective multiple earthing or TNC-S) was utilised in the 80's, the risk of elevated voltages on different exposed conductive parts has increased. It is for this reason equipotential bonding is necessary. Neutral and Earth a marshalled together at the meter position (as well as the substation) and therefore the installation earth potential (that being the same as the neutral ) can be a number of volts different to true earth potential.
@ryandow3954
@ryandow3954 3 жыл бұрын
Really enjoying these videos 👍 keep them coming!
@monikanader9454
@monikanader9454 3 жыл бұрын
Great video, very informative. Thank you👍👍👍
@kelvinjones1995
@kelvinjones1995 3 жыл бұрын
👍 Always something to learn from the Guru 😎
@hazelbulgin638
@hazelbulgin638 3 жыл бұрын
Brilliant keep them coming 👏👍🏾
@hussaingonoo959
@hussaingonoo959 3 жыл бұрын
Another fantastic Video
@saltnvinni1
@saltnvinni1 3 жыл бұрын
Fantastic video
@martynlewis5901
@martynlewis5901 3 жыл бұрын
Excellent, thanks. ACS due next year so this is all good prep. 👍🏻
@vahidkaregar8049
@vahidkaregar8049 3 жыл бұрын
Brilliant, really informative , please keep them coming🙏
@paigedarby4997
@paigedarby4997 2 жыл бұрын
Hi Derek Great videos. Would you be able to do more videos on Unsafe Situations and how to best classify them. Are there any techniques to better identify them or is it just literally a case of keep practicing and revising? I did well in this video but struggled on part 1. Any help would be great on how to best revise. Thanks for all your other video as they've helped loads.
@thomasblades4059
@thomasblades4059 3 жыл бұрын
Top video
@leaturk11
@leaturk11 3 жыл бұрын
Great stuff, keep them coming.
@hamzaparvais3948
@hamzaparvais3948 2 жыл бұрын
Brilliant thank really good mate
@wallmackari3885
@wallmackari3885 2 жыл бұрын
the requirement of the equpotential bonding is clearly on the out let pipe from the meter , so I think it should be there to protect what ever inside the property regardless the inlet pipe or before the meter installation . if not there I think it should classify as AR and Not RIDDOR
@localtradesuk8572
@localtradesuk8572 Жыл бұрын
Hi Derek great videos, Can you make more videos like this as it does help. I got a questions does fly screen on a vent does that reduce air so you need a bigger vent or no? thanks
@tomkatgastraining
@tomkatgastraining Жыл бұрын
No you can’t use a vent with a fly screen because it can get blocked by insects and spiders webs.
@aghasahib4703
@aghasahib4703 3 жыл бұрын
Brilliant video. Thanks alot mate
@timeintheuk
@timeintheuk Жыл бұрын
Helpfull ta
@jerzyszczachor724
@jerzyszczachor724 Жыл бұрын
Interesting about bonding 18th edition amendment 2 dose not required bonding on incoming services to the building if they are plastic. However if no bonding on water mains any current leakage under ground could travel through water also so if no bonding current could be present on boiler body before travel through earthing from a spur but if you disconnected power supply and bonding the appliance body becomes live. Also there is a major issue where problem was found the nutreal on electricity supply become faulty the current found way through earthing path. So there was gas explosions cause by that and they found fault where on gas pipe 35A has been recorded .
@abchannel3737
@abchannel3737 3 жыл бұрын
Your are the best 🌹👍👌✌️
@suewarrington8155
@suewarrington8155 2 жыл бұрын
👍Sue Warrington
@jpfrench1496
@jpfrench1496 3 жыл бұрын
Another great vid
@mj0n4id36
@mj0n4id36 3 жыл бұрын
Brilliant video. I did better in this one than I did in part 1 😎. At 14:15 when talking about the flueless space heater and how it should be at least 1 metre away from a vent, how about a door? I saw this type of flueless space heater installed in a hallway not to far away from the main door to the house. What are the requirements for that? Thanks Derek. Much appreciated 👍🏻 Asian Jon. Training.
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
The door is not that much of a problem because it’s closed most of the time and it’s a big area. The ventilation being too close is a problem because it could stop the ASD shutting down and make the room vitiated.
@mdillon1976
@mdillon1976 3 жыл бұрын
8 00 phone gas board 🤣🤣got one wrong derek cheers 👍
@rayc1503
@rayc1503 3 жыл бұрын
Strange IET electrical regulations state that if there aren't any extraneous conductive parts on the incoming mains and the incoming underground pipe is of non conductive material then no equpotential bonding is required. However according to BS 7671 regulations differ stating PEB must be fitted within 600 mm and before the first T branch in pipework. I can't understand why regulations differ through both industries. I'm completely for the installation of PEB however other electricians would argue that IET regs differ 🤷‍♂️. If on the Ecv there's a red ring present this indicates no PEB required. If there's no red ring downstream of the ECV then install a PEB clamp. It should be just below the ECV in any case.
@joaovittoria2533
@joaovittoria2533 3 жыл бұрын
👍👍
@louisdisbury9759
@louisdisbury9759 2 ай бұрын
Hi Derek regarding earth bonding on gas meters if its a propathene gas service coming in that will not act as an earth conductor but regardless the earth bonding on the gas meter is 10mm goes back to the Earth block on the consumer unit and will offer protection if gas appliances go to earth and incidentally RCD s will not operate if you do not have good earth, regarding flueless gas fires an engineer fitted one about ten years ago and never checked the operating pressure which was double what it should have been, The oxy pilot failed to operate because an air vent fitted close to the appliance fed fresh air to the pilot the result was the death of an 18-year-old girl and her dog overcome by monoxide fumes due to incorrect operating pressure the Installer was sentenced to 3 years in jail I think the minimum distance for ventilation to a flueless gas fire is 1 metre from the appliance but after learning about that Incedent my company no longer fits them.
@lazylady81
@lazylady81 3 жыл бұрын
so paint on a flue or boiler is AR?
@marcinmasalski4183
@marcinmasalski4183 3 жыл бұрын
Marcin Masalski 👍
@stevehouse3904
@stevehouse3904 2 жыл бұрын
GSIUR REG 7(1), PIPEWORK SUITABLE FOR GAS BEING USED IN AN INAPPROPRIATE LOCATION, would that include being less the 25mm from light switch?
@SuperWayneyb
@SuperWayneyb 3 жыл бұрын
🤘🤓🤘
@M20DAN
@M20DAN 2 жыл бұрын
tomkat👍
@viran8121
@viran8121 3 жыл бұрын
👍🏽
@andyjones7836
@andyjones7836 3 жыл бұрын
👍
@bryanwilliams3827
@bryanwilliams3827 2 жыл бұрын
Bryan Williams
@mustafaakbari6231
@mustafaakbari6231 2 жыл бұрын
Mustafa akbari
@leaturk11
@leaturk11 3 жыл бұрын
The meter had a open uncapped pipe, so I marked it as ID
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
The question was about the meter being inside the property not the open end 😜
@jon-paulward4580
@jon-paulward4580 2 жыл бұрын
Jon-Paul Ward
@stephenhumphreys4099
@stephenhumphreys4099 2 жыл бұрын
Stephen Humphreys
@richardhodgson7443
@richardhodgson7443 3 жыл бұрын
Great video again Derek, brilliant for revision. Would you mind being the first person to actually demonstrate / show the procedure of unsafe situations practically. Ie actually disconnecting appliance, capping off meter, etc. Thanks 🙏
@danielriglin9333
@danielriglin9333 2 жыл бұрын
Dan Riglin
@carlhutchinson3458
@carlhutchinson3458 3 жыл бұрын
Medium pressure gas meter has an open end on outlet 🤔 is that no ID? 🤔
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
The scenario was the medium pressure meter was installed inside not the open end that’s why I gave scenarios not just said what’s wrong but yes an open end is ID
@craighurst3599
@craighurst3599 3 жыл бұрын
CH👍
@steve250276
@steve250276 2 жыл бұрын
steve ward
@danielcarragher6628
@danielcarragher6628 3 жыл бұрын
Daniel carragher
@secondchance4498
@secondchance4498 3 жыл бұрын
ChrisTaylor
@stevehouse3904
@stevehouse3904 2 жыл бұрын
I meant socket!
@BrothersGrim2012
@BrothersGrim2012 3 жыл бұрын
No Bonding
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
Is that nor ID and riddor then
@BrothersGrim2012
@BrothersGrim2012 3 жыл бұрын
@@tomkatgastraining no Earth bonding i would make a note on the cert, advise the customer to get a qualified electrician to get it done for them
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
@@BrothersGrim2012 don’t you mean leave a bonding notice at the gas meter to advise the responsible person earth bonding could be required
@BrothersGrim2012
@BrothersGrim2012 3 жыл бұрын
@@tomkatgastraining I’m only learning so far so just had a go without looking in book, if I’d of referred to book then I would of have a fuller answer
@tomkatgastraining
@tomkatgastraining 3 жыл бұрын
@@BrothersGrim2012 a lot more training required joe but keep it up 👍🏻
@mattrowntree3359
@mattrowntree3359 Жыл бұрын
15 Min into vid the gas meter has open end and you've classed it as ar and not Id 😮... the medium pressure one ..
@tomkatgastraining
@tomkatgastraining Жыл бұрын
The question was about medium pressure inside a property not about an open end on a gas pipe. I said at the beginning of this section it represents not this is what you find so a medium pressure meter inside a property is AR. For your information there is a disk in the meter outlet also so still no open end.
@warmastermoran6418
@warmastermoran6418 3 жыл бұрын
JD Moran-Campbell. Training
@chrisjones4500
@chrisjones4500 2 жыл бұрын
👍👍
@lewisclarke4765
@lewisclarke4765 2 жыл бұрын
👍🏻
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН
Арыстанның айқасы, Тәуіржанның шайқасы!
25:51
QosLike / ҚосЛайк / Косылайық
Рет қаралды 700 М.
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 45 МЛН
The Dome Paradox: A Loophole in Newton's Laws
22:59
Up and Atom
Рет қаралды 462 М.
Tech Talk - Episode 1 - Gas Safe Register
14:09
Gas Safe Register
Рет қаралды 2,9 М.
Tech Talk - Episode 3 - Gas Safe Register
11:38
Gas Safe Register
Рет қаралды 956
TWISTED: The dramatic history of twisted-pair Ethernet
28:30
The Serial Port
Рет қаралды 178 М.
Regulation 26.9 Gas Engineer Safety Checks | NGCFE
17:04
Allen Hart
Рет қаралды 45 М.
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН