Regulation 26.9 Gas Engineer Safety Checks | NGCFE

  Рет қаралды 43,356

Allen Hart

Allen Hart

Күн бұрын

Пікірлер: 39
@AllenHart999
@AllenHart999 2 жыл бұрын
ngcfe.co.uk/
@raul835
@raul835 2 жыл бұрын
SUGGESTION: Gas fires. How to recognise the different types. To this day, I don't really know if I'm looking at a radiant, dfe, inset or whatever else. Fires are my Achilles heel Lol.
@edmetcalfe8974
@edmetcalfe8974 2 жыл бұрын
What would be really useful is a video explaining how to proceed if the gas rate is not within -10% and +5%. A lot of these gas courses cover how to gas rate but don’t really go into how to classify when it’s not within tolerance and also how to rectify.
@rjv9858
@rjv9858 Жыл бұрын
Upsize / downsize pipe to achieve gas rate
@edmetcalfe8974
@edmetcalfe8974 Жыл бұрын
@@rjv9858 assuming the problem is with pipe sizing. Lots of things can adversely affect gas rate.
@rjv9858
@rjv9858 Жыл бұрын
@@edmetcalfe8974 what like? All got to do with the gas pipe itself, either too big, too small, blocked, too many bends etc if that’s what you mean? all boils down to pipe though
@JayGasEssex
@JayGasEssex Жыл бұрын
@@rjv9858 Could also be faulty regulator at the meter causing low pressure, distance from meter to appliance, pipe size, gas escape on system, bad gas valve? many reasons.
@ukgasengineerssolutions
@ukgasengineerssolutions Жыл бұрын
​@@JayGasEssexyour standing pressure would have clarified a faulty governor
@robwoods8160
@robwoods8160 2 жыл бұрын
Great presentation. Should have the customers watching this. Especially the penny pinching landlords.
@tommyblackman7119
@tommyblackman7119 2 жыл бұрын
Great video.. Can how about a video on gas fires on 26.9 checks
@sergiofernandez3725
@sergiofernandez3725 2 жыл бұрын
Have you seen that some manufactures of boilers are stating the type of circuit breaker that is needed? I saw on a recent discussion board that a type B was needed? It also went on to state that they recommend a SPD (surge Protection Device) in the fusebox/fuseboard/CU to protect the sensitive equipment on the PCB of the boiler
@anthonygreenwood4486
@anthonygreenwood4486 3 ай бұрын
Why do the Big Gas companies only do a tightness test on a landlords, But private households just bring fault code up on a boiler and don’t do mini tightness? KZbin warriors don’t want to talk about it
@jamstar116
@jamstar116 2 жыл бұрын
I really enjoy this type of videos, good job guys
@hvacgas5292
@hvacgas5292 2 жыл бұрын
Good video.👍...when you gas rate cooker ,do the oven and grill have to be switched on as well?
@KS-we8ov
@KS-we8ov 2 жыл бұрын
Yesss Allen done and dusted...but great video to learn from 🙏
@kevj1964
@kevj1964 2 жыл бұрын
11.50 :- 3 burners on a hob to Gas Rate ? is'nt 3 burners on a hob to check for working/operating pressure?
@michaelhunt848
@michaelhunt848 2 жыл бұрын
Yes mate. Slip of the tongue. Well spotted.
@theplumber4934
@theplumber4934 Жыл бұрын
Can you clarify the 5% above and 10% under as TB 141 states that under BS297 & BS EN 483 the 5% and 10% are tolerances during manufacture of the appliance for CE approval. However there is no specific tolerance stated anywhere that is applicable to gas rating at the time of commission or servicing. I think this is possibly a rule that has got mixed up as it has been past down from person to person since 2012 when it came out.... Thanks
@yaminhetingplumbingleicesteruk
@yaminhetingplumbingleicesteruk 3 ай бұрын
great presentation
@maximuswong3092
@maximuswong3092 11 ай бұрын
Allen, PLEASE PLEASE do i video on regulation 26.2 nobody talks about this regulation.
@AllenHart999
@AllenHart999 11 ай бұрын
I will look into it. Thanks.
@theheatingdoctor
@theheatingdoctor 2 жыл бұрын
Great video but you ideally want to spray LDF generously around the isolation tap of the gas under boiler once disturbed, not just the isolation screw. When disturbing the ECV by moving it also wanna spray around the handle, spray the anaconda and the two nuts in and out of the meter for peace of mind. Great video tho, nice and informative. Video suggestion would be safe electrical isolation, safe to touch test and checking the polarities etc on the boiler and the house. Many a time do I have a chat with engineers and they just don't do it. An idea mate :) Checking the voltages across live and switch live on diverter valves is another idea mate, allowing newcomers to establish correct functioning (or incorrect) of the switch itself.
@tomadams94
@tomadams94 2 жыл бұрын
All true however this has nothing to do with tightness tests or meters other a than gas rating so you are really only going to use ldf on the appliance iso and / burner pressure test point
@theheatingdoctor
@theheatingdoctor 2 жыл бұрын
@@tomadams94 true, just popping a few extra safety things in there in case a new starter sees something they wanna pick up; if they anything like I was back in day they will be watching everything and reading everything :)
@tomadams94
@tomadams94 2 жыл бұрын
@@theheatingdoctor no it’s good practice a lot of people don’t spray valves after touching them! 👍🏻
@traian23us
@traian23us Жыл бұрын
1097:31=35.38 kW gross a shorter way of doing it
@garytreverton-black3693
@garytreverton-black3693 2 жыл бұрын
No flue integrity test?
@martynlewis9020
@martynlewis9020 2 жыл бұрын
Isn’t that only if the flue is in void?
@davidhallas9063
@davidhallas9063 9 ай бұрын
why didn’t he start gas rate test at the rite point on the gas meter ?
@milkman100001
@milkman100001 2 жыл бұрын
didnt check your analyser for O2 before testing the boiler. and then no flue integrity was done either.
@xudongpeng2729
@xudongpeng2729 Жыл бұрын
Can I ask If the gas rate I got lower than manufactory book how can I do thanks.
@jockster5525
@jockster5525 2 жыл бұрын
Great video thanks for your efforts lads ..
@mikeportch8725
@mikeportch8725 7 ай бұрын
Another great video allen
@tomstrutton4351
@tomstrutton4351 2 жыл бұрын
These videos really are good Allen
@petermcdonagh6669
@petermcdonagh6669 2 жыл бұрын
Thanks Allen top video
@smithersjones3018
@smithersjones3018 Жыл бұрын
Great video. Cheers
@Ash-fy2mn
@Ash-fy2mn Жыл бұрын
It’s a shame these rules only apply to certain engineers, national gas supplier contractors exempt according to Gas Safe! How does that work? One rule for us and another for them, surely NG has the same risk whoever works on it? No wonder people leave this trade.
@Purebeltersteve
@Purebeltersteve 2 жыл бұрын
Personally if your a gas engineer and you dont know 26.9 checks, your not competent and should never be doing gas.
@SuperWayneyb
@SuperWayneyb 2 жыл бұрын
🤘😎🤘
Carbon Monoxide Alarm Activation Guidance | NGCFE
15:37
Allen Hart
Рет қаралды 25 М.
How To Fill Out A Landlord Gas Safety Check CP12 GGIUR 26.9
38:42
哈哈大家为了进去也是想尽办法!#火影忍者 #佐助 #家庭
00:33
Running With Bigger And Bigger Lunchlys
00:18
MrBeast
Рет қаралды 120 МЛН
Bike Vs Tricycle Fast Challenge
00:43
Russo
Рет қаралды 104 МЛН
Миллионер | 1 - серия
34:31
Million Show
Рет қаралды 2,2 МЛН
Tech Talk - Episode 1 - Gas Safe Register
14:09
Gas Safe Register
Рет қаралды 2,4 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,2 МЛН
Tightness and Let-By Tests and Tracing Leaks
20:12
Pass Your Gas
Рет қаралды 2,8 М.
ACS GAS TRAINING / CONTROLS | NGCFE
34:40
Allen Hart
Рет қаралды 28 М.
How to check working pressure of an appliance
7:47
Able Skills
Рет қаралды 26 М.
Gas training picture quiz on unsafe situations  part 9.
13:52
Tomkat Gas Training
Рет қаралды 15 М.
How to diagnose problems on gas stovetop or cooktop hob and how it works.
22:12
哈哈大家为了进去也是想尽办法!#火影忍者 #佐助 #家庭
00:33