Great find! I think someone should really tell an engineer to angle the 2 outer pipes away from the center pipe, so that we can get better access to braising those fittings during installation of the new one! Thanks for this one. I'll look out for this. Especially since we primarily install Lennox & Trane.
@loganc3393 жыл бұрын
Encase you haven't figured it out yet, engineers couldn't give two shits about u lol
@adamspears38193 жыл бұрын
@@loganc339 You are wrong about that. There are reversing valves designed this way. Nice try though!
@loganc3393 жыл бұрын
@@adamspears3819 it seems like engineers build units purely to screw with the techs that work on them. They dont give a damn lol. If anything they think it's funny to do stuff like put screws in places you can't reach
@mariobryant88034 жыл бұрын
The inside of those three ways can affect the system depending on the mode - gotta check everything that can affect the three way reversing valve. They can be tough to figure out, those seals can affect the system bigtime. Great video in general.
@joepalooka47203 жыл бұрын
Doing this at work tomorrow, I was trying everything in mind to not lead me here but symptoms are hard to ignore , that hot gas bleeding into my suction side giving me a 2 to 1 compression ratio on a scroll , doesn’t help it’s 2000 degrees in Southern AZ
@benjaminreynolds38666 жыл бұрын
Holy crap I think I've got the exact same issue going on at one of my customers house. Found bad compressor, changed it. The way it acted seemed very odd. I've been leaning towards the reversing valve but it also seemed as it the compressor wasn't pumping right so I ordered a new compressor under warranty and new reversing valve just to get it all done at one time. My company does a lot of home warranty, it sucks but man our company have really thrived over the years because of it.
@brunoshvac25783 жыл бұрын
I have heard about this, however never seen it. Great video.
@THEMOWERMEDIC13 жыл бұрын
Will one hang up a little? Noticed mine not cooling as good as good as it was yesterday. Cycled my system back and forth Now it’s cooling fine. What gives?
@DJV940228 ай бұрын
Heres a tip: tap the reversing valve lightly with a hammer til it gets to what you want. Just like your old starter on your cars or work vans when you tap it and it works there goes to your indication. You could also fix it by tapping it on a new one.. sometimes you gotta have faith .cause in the automotive world mechanics say this and that could not work then you do it and it works!
@terrancethomassr89474 жыл бұрын
I am happy I found this video I am going through the same thing right now with the same type of brand AC outside unit I’m going to show this to the AC Man
@DJV940228 ай бұрын
You mean Goodman service rep
@vernroach34135 жыл бұрын
Damn good video....Excellent camera work...Thank you for making this.
@JisINSANE35 жыл бұрын
At my job we had high head pressure and low low side pressure. Had a horrible ac company come out and claimed the liquid line dryer was clogged replaced it. $1200 charge. Well the same shit started happening within a week and the evaporator was hissing except this time instead of freezeing at the lower portion of the evap it was heating on the lower end with the same head pressures. After seeing the repairs these idiots did on other ac systems, Like electrical taping caps hanging under the condensor fans exposed to the elements I said the hell with that. So I smacked the reversing valve with a rubber mallet and WOW the damn thing started working. I learned that cause about 25% of our amana PTACS do the same damn thing. Heat when they are supposed to cool. Just smack the damn valve once.
@rexford90192 ай бұрын
Was that valve made in China? Goodman troubleshooting manual says they changed all their model’s reversing valves from Dunan to SanHua. So much for made in the USA.
@love2hvac Жыл бұрын
Great video, I have not seen one like that.
@vernroach34135 жыл бұрын
Good video, good catch for the newer guy...I'm betting he felt good and this must have built his confidence up....One of the most important things that comes with experience only...Thanks for the video.
@jimeburg48282 жыл бұрын
Have you heard of the Carrier Heat Pump doing the same thing being stuck on the Defrost cycle/
@ChrisVanSlykeCVS5 жыл бұрын
This might be my problem....I have a 15 year old york R-22 outside unit which heats but will not cool. When I program in cooling mode everything appears to be working ie. outside fan works, I hear the condenser, inside fan is blowing air, air filter and coil are clean but it does not cool and I don't see and water condensing on the inside drain. Earlier this year I had the refrigerant checked and it was low. We pressurized the system looking for leaks but there was none found it held 350 PSI for 30 mins. The tech though it might have been the gauge valve since when he opened the cap he heard a it of gas escape. So we added refrigerant to the level required 5 lb 11 ozs. After this the heating worked fine compared to before when it was going constantly with little heat. Fast forward a few months now I want to cool and it does not work but heating does. Cooling didn't work last summer either but I figured adding refrigerant would fix the no cooling problem this year which turned out to be wrong. In cooling none of the lines feel cool but in heating the large line gets very hot to the touch. What would you suggest to check now or is it most likely the reversing valve? Great video thanks!
@jesusbautista79622 жыл бұрын
DID YOU GET THIS FIXED, CAUSE MINE IS DOING THIS RIGHT NOW. AND HOW?
@ChrisVanSlykeCVS2 жыл бұрын
@@jesusbautista7962 Mine was leaking refrigerant slowly from somewhere but we could not find where. I fixed it by replacing the outside and indoor units since the air handler had to match the new refrigerant.
@bobboscarato13132 жыл бұрын
@@ChrisVanSlykeCVS Hey that's not fixing it; you replaced the entire system!
@eddiekilby6 жыл бұрын
Just work on one for a friend his is doing the same thing bypassing in cooling but works in heating.
@paulbailey57426 жыл бұрын
Have you had one build up pressure on the high and low side then make a hissing sound but not shut off the compressor? Head pressure will get up to 450 suction gets to 275-280 the it "pops" off and the pressure goes back to normal.
@rickpazmino58206 жыл бұрын
Yes. Not necessarily due to a reversing valve issue exclusively, but any kind of head pressure problem. Some compressors have internal high pressure reliefs that cause head pressure to bypass internally (possibly causing the housing noise) to the compressor if there is a high pressure condition. A hot system, compressor, low capacity operation, and your previously mentioned pressures, may be signs of this. Just a guess, but a blocked reversing valve could indeed cause this.
@726scooty5 жыл бұрын
Thank you guys I’m having this problem on a brand new Lennox heat pump I installed. I ran the unit added a pound for line set length unit ran for thirty minutes perfectly. Customer says she cut it off it would cut off I was thinking reversing valve cause I kept hearing it move or attempt to move but I’m my pressures would go to almost 600 and cut off on high head pressure can’t be a bad compressor right has to be the reversing valve? Help me please? I didn’t not amp out the compressor it only runs for a short period and I don’t want damage anything at 600 psi. I was going evacuate and weigh charge back in. Any other suggestion
@hillside70774 жыл бұрын
@@726scooty could be bad txv in condenser
@RobertTuck-vo8cw6 ай бұрын
A reversing valve is a 4-way valve, Notice the 4 ports?
@gotchaplumber6 ай бұрын
Good diagnosis.
@ravisingh12854 жыл бұрын
these valve technology is bad?
@samuelzendejas5651 Жыл бұрын
Where did you purchase this valve from and what brand is it ?
@Hvacmania5 жыл бұрын
If the indoor unit is second stage does the outdoor unit have to be second stage also?
@shuaib89084 жыл бұрын
Did you cut those pipes with an angle grinder?
@HarryHafsak Жыл бұрын
Hopefully the new one never got hung up on copper shavings lol
@alexv38665 жыл бұрын
Great video, thanks!
@MySOBER-Life3 жыл бұрын
Good video
@arthurmitch2 жыл бұрын
Well i have got one.... restriction that blows the compressor caused by 3 way valve
@OcRefrig7 жыл бұрын
Good show.
@patstansberry81897 жыл бұрын
Good job
@jollyscaria1922 Жыл бұрын
Systom working revsl conrolld gastopinv sy oen gax pas sys stop het systom fee0o