No video

Trane Variable speed XV18 not cooling.

  Рет қаралды 2,926

My HVAC Life

My HVAC Life

Күн бұрын

Communications fault on the Trane XV18 Variable speed system. #hvac #hvaclife #hvacservice #hvactechnician #hvacrepair #heatingandcooling #airconditioner #inverter #trane ‪@TedCookHVAC‬ ‪@HVACShopTalk‬ ‪@HughesManHVAC‬ ‪@HVACOvertime‬ ‪@hvacotj‬

Пікірлер: 21
@dillonlexington
@dillonlexington Жыл бұрын
Great video sir, I am not a fan of the system that you worked on, just for the fact that I am a basic kind of guy, the fancy controls to me are just one more thing to break down. That is just me though.
@douro20
@douro20 Жыл бұрын
They are VERY expensive to service. I would never own such a system unless I could afford the cost of parts. And the ComfortLink HMI is mandatory on these communicating systems.
@myHVAClife
@myHVAClife Жыл бұрын
@@douro20 No additional cost to service from us, and nothing is mandatory. Annual maintenance is the same as any unit and they have a 10 year warranty.
@douro20
@douro20 Жыл бұрын
@@myHVAClife Hmm...I thought on communicating units you had to have the ComfortLink to be able to use them.
@markcollins457
@markcollins457 Жыл бұрын
My own back ground in HVAC goes back to the 70's when we became a GE contractor our trucks had, "WE BRING GOOD THINGS TO LIFE" then GE sold the hvac to Trane it always was tough equipment but as a contractor you must maintain a good relationship with your customer Trane equipment cannot be maintained by a non factory trained mechanic and the I have witnessed a lot of butchered units due to inexperienced service.
@bobboscarato1313
@bobboscarato1313 Жыл бұрын
@@markcollins457 True and the same applied to American Standard units.
@donnyjackson1908
@donnyjackson1908 Жыл бұрын
Im a newer tech. Ran into one of these HP today. Pumps itself down in cool and shows LSPP CLG CO. Switch to heat and showed LSPP HTG CO. Then it ran in Heat at low speed and says Heating Derate. Looking in the previous Codes it has has a low charge code and multiple lockouts…At first I was thinking EEV valve after the LSPP CLG CO but EEV valve ohms good. 13.8v from Distribution board to EVC. ET and GT sensors have proper DC voltage as well… any tips before I weigh out the charge and see if it is in fact “low Charge”? First one of these I’ve ever had to work on.
@elijahgoodman3140
@elijahgoodman3140 Жыл бұрын
Great video. Besides line voltage, everything else is DC volts correct?
@myHVAClife
@myHVAClife Жыл бұрын
YES, 24v to power the tstat and at the outdoor unit if connecting a load management box. Everything else is DC. Basically only 3 tstat wires to the tstat and 2 tstat wires to the outdoor unit.
@realSamAndrew
@realSamAndrew Жыл бұрын
I like the umbrella. What kind is it?
@myHVAClife
@myHVAClife Жыл бұрын
WALMART $20
@DavidWeinberg-cm9xd
@DavidWeinberg-cm9xd Жыл бұрын
Pretty complicated for a straight A/C Condensor? Looks to be very low amp draw, which would save a good amount of electricity? Wanted to get a variable unit, but they are double the price of the one I ended up getting? Are they very problematic, compared to regular units?
@myHVAClife
@myHVAClife Жыл бұрын
We have been installing these for 8 years, no issues other than the occasional sensor out of range, yes they are costly and over the short term the savings probably does not pay you back completely for the additional cost, but the climate it maintains in the house cannot be matched! These unit do a great job at maintaining consistent temps and humidity levels.
@DavidWeinberg-cm9xd
@DavidWeinberg-cm9xd Жыл бұрын
@@myHVAClife The On/OFF system really does suck in a humid environment, like I live in FL? That's why I wanted the variable system, so it's not such a drastic change?
@bobboscarato1313
@bobboscarato1313 Жыл бұрын
@@DavidWeinberg-cm9xd Well you could get a variable system in about 20 years!
@chrissipple1018
@chrissipple1018 Жыл бұрын
It looks like they use a trickle heat system instead of a crankcase heater. Inverter equipment are a bunch of crap, Just to get what .00002 watt savings. I don't know how much wattage you really save but it not worth the money or the problems for these systems. I'm not against you just the inverter systems and the people who buy them. The rich
@myHVAClife
@myHVAClife Жыл бұрын
I respect your opinion. We have installed over 200 of these units in the last 8 years. And being a TRANE dealer, they have been our least problematic unit from TRANE. Very few problems, a turned off breaker would stop the simplest of systems. I do prefer 'keep it simple' , but I have to learn how to work on what my company installs. The more time you spend with them the easier they are to work on. But yes, They are marketed to a more wealthy consumer. But they have commented on having very impressive reductions in energy costs and a much more balanced comfort level in the home.
@douro20
@douro20 Жыл бұрын
Just don't gasp when you look at the cost of service parts. These are definitely rich boys' toys and I don't envy the people who can afford them.
@bobboscarato1313
@bobboscarato1313 Жыл бұрын
@@douro20 Well if you go buy groceries or anything else, you know costs have gone up 50 to 60% or more; gas when down a bit but we never know when that will change!
Brand New TRANE System Not Cooling
19:35
John Israel HVAC
Рет қаралды 38 М.
How to Work on Mini Splits?
30:30
Taddy Digest
Рет қаралды 116 М.
PEDRO PEDRO INSIDEOUT
00:10
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 8 МЛН
Yum 😋 cotton candy 🍭
00:18
Nadir Show
Рет қаралды 7 МЛН
Little brothers couldn't stay calm when they noticed a bin lorry #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 20 МЛН
Before VS during the CONCERT 🔥 "Aliby" | Andra Gogan
00:13
Andra Gogan
Рет қаралды 9 МЛН
trane unit with bad RTRM board
14:30
Anthony Reardon hvacr
Рет қаралды 33 М.
Training Day! New TAMX TRANE LINK communicating system.
30:18
My HVAC Life
Рет қаралды 3,5 М.
HVAC Brands that Suck! - Criteria to Finding Good HVAC. How to Know!
12:44
HVAC Guide for Homeowners
Рет қаралды 256 М.
Trane Link Communications.
20:17
My HVAC Life
Рет қаралды 1,5 М.
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 637 М.
Poor ventilation causes mold issue.
10:00
My HVAC Life
Рет қаралды 725
Refrigerant Overcharge Troubleshooting and Prevention
21:47
HVAC School
Рет қаралды 178 М.
Installing RunTru By TRANE Split System | Would I RECOMMEND Them??
16:51
PEDRO PEDRO INSIDEOUT
00:10
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 8 МЛН