Transformer Banks: Overview

  Рет қаралды 98,477

CTE Skills.com

CTE Skills.com

Күн бұрын

For ad free high quality videos visit us @ www.cteskills.com
In this video Mr Rusty gives a brief overview of "Transformer Banks". He covers several different types, their uses, and the importance of proper wiring and types of connections. In future videos we will be getting more in depth on the specific types of banks.
This video was created with Lamar Institute of Technology at the Frank Robinson Center in Silsbee, TX with the help of Russell Koenig (Program Director).

Пікірлер: 49
@Woodstepper74
@Woodstepper74 Жыл бұрын
19 year lineman just learned something. Thank you sir.
@paulx7620
@paulx7620 4 жыл бұрын
Thank you reading this stuff is almost impossible for me to do, for me seeing a person and listening really helps.
@phuxus558
@phuxus558 5 жыл бұрын
this guy is GREAT!!!
@simplytrolling6869
@simplytrolling6869 3 жыл бұрын
“Thisin’ we can’t put on lighting it reads about two hunnn-erd ate volts two hunnn-erd ate volts on hunnn-erd twinny volt system dunn werk tew well, cause lotta smolk n stuff liiii dat”… this man speaks my language
@CTESkillscom
@CTESkillscom 11 жыл бұрын
Thanks ThedudeVip3r1990. Please like and subscribe. We'll be adding much more next semester.
@mohammedfofanah6988
@mohammedfofanah6988 6 жыл бұрын
so difficult i know the easy way for this system poor American system.
@beowens231
@beowens231 4 жыл бұрын
Not a bad job at all sir :) Not enough young Lineman, out in the field, get to see 3 pot closed Delta Power only corner ground. Delta/ Delta or Wye /Delta corner ground, So in the future will you please show the Wye/Delta or Delta/Delta corner ground Two Pot Bank, they are rare but do exist. Thanks, Blane Owens.
@jolyonwelsh9834
@jolyonwelsh9834 7 жыл бұрын
You can use the high leg for modern LED light fixtures. Most of them have universal voltage drivers in them (100-277volts). Just make sure you use a straight rated 240 volt circuit breaker.
@danielelise7348
@danielelise7348 Жыл бұрын
Here in Australia we just hang a single 3PH transformer & be done with it, although our voltage is 240/415V but each transformer feeds about 40 domestic installations,single phase,most 3PH installations have their own transformer.
@jimmybrad156
@jimmybrad156 5 ай бұрын
Out of interest, do you happen to know what those transformers weigh, and their VA rating? (The type you see on a wooden pole in a residential street.) Our place is 3ph but doesn't have its own transformer (WA). Not sure where it is to be honest. All I know is that once or twice a year, 1 of the phases will go 'brown', then a few minutes later all 3 will go dead. I guess they need to fix it and never get around to it.
@tedlahm5740
@tedlahm5740 Жыл бұрын
Comment please. the term phase voltage and line voltage get interchange at times. Only place PHASE voltage can be measured at the transformer lug. Inside the property that would be the line voltage. comment please
@simplytrolling6869
@simplytrolling6869 3 жыл бұрын
6:28 the dude hollerin
@williammay5300
@williammay5300 6 жыл бұрын
What about singal transformer connected to all 3 power lines??
@lendavidhart9710
@lendavidhart9710 4 жыл бұрын
That power leg, some guys call it a bastard leg
@REWYRED
@REWYRED 10 жыл бұрын
Interesting! 4 wire delta is unheard of where I am, 3-wire ungrounded delta ( with use of ground indicator lights) and open delta were common but are rare now.. Basically all there is to choose from for low voltage 3 phase power here is 120 / 208V or 347 / 600V.... 347V being a common voltage for commercial lighting.
@steves009
@steves009 8 жыл бұрын
omg you make it look so hard. why the 3 transformers why not just one with 3 HV in?
@melmc8888
@melmc8888 8 жыл бұрын
Lots of advantages doing it that way.
@steves009
@steves009 8 жыл бұрын
+Mel Mc don't see how. at least with 1 it can supply 3ph and single phase at the same time. Makes more work than needed
@melmc8888
@melmc8888 8 жыл бұрын
+Stephen Smith 2 banks can be run as open Delta thus still supplying power to a business if one of the three fail...Also 3, 300 lb transformers are easier to transport and put on a pole than 1 that weighs 900 lbs
@steves009
@steves009 8 жыл бұрын
+Mel Mc well I have a 3ph transformer supplying my house and its rated at 100kva but only 1ph out and 3ph supplying the dairy shed and looks cleaner on the environment
@steves009
@steves009 8 жыл бұрын
+Mel Mc and only one set of HV wires from the HV line
@arturoalmanza1482
@arturoalmanza1482 6 жыл бұрын
Yeah rusty
@rtz549
@rtz549 10 жыл бұрын
Why aren't all the connections on the transformers ever labeled?
@CTESkillscom
@CTESkillscom 10 жыл бұрын
rtz549 I don't have an answer for you on that. Maybe email Mr. Rusty @ Lamar Institute of Technology. That is where we filmed this. Thanks for watching and we do appreciate your question.
@FrankCerank
@FrankCerank 9 жыл бұрын
Because on all Distribution transformers which have additive polarity the Primary bushings are H1 and H2 from left to right and the Secondary bushings are X1 X2 and X3 from right to left.
@yipster0290
@yipster0290 7 жыл бұрын
That is incorrect. For additive polarity the secondary bushings will be labeled x3, x2 and x1. The primary bushings will always be labeled H1 and H2 regardless of the polarity of the transformer.
@linemanap
@linemanap 7 жыл бұрын
Phil McCracken you just said the same thing he did lol
@steves009
@steves009 7 жыл бұрын
rtz549 cos Americans​ can't read
@steves009
@steves009 7 жыл бұрын
Does the US have or use SWER (single wire earth return) systems not rural areas?
@metersocket00
@metersocket00 7 жыл бұрын
Stephen Smith It depends on the utility supplier. I live in Exelón power territory (north east US) and they use wye systems, due to the old age of their lines. So SWER systems are very common here, especially in residential areas. But in newer installed systems, in rural or growing cities, they are primarily delta, so at least 2 phases are ran in those systems.
@heronimousbrapson863
@heronimousbrapson863 5 жыл бұрын
SWER is used in rural parts of Alberta, Canada.
@redshift1976
@redshift1976 3 жыл бұрын
That guy in the red jumpsuit looks like a real dummy 6:53
@firefightr_spike3846
@firefightr_spike3846 2 жыл бұрын
ahahah I see what you did there 😂
@jolyonwelsh9834
@jolyonwelsh9834 6 жыл бұрын
Why bother with a wye primary? Use a Delta primary thus doing away with the risk of feroresonance in the first place. Just about all your 3 phase dry type transformers have Delta primaries probably for that very reason.
@jolyonwelsh9834
@jolyonwelsh9834 7 жыл бұрын
Long be the high leg.
@rafalszachnowicz2831
@rafalszachnowicz2831 4 жыл бұрын
Haaaaaaa! It's easier to understand if someone simply tell you what's what, isn't it?
@mca1960
@mca1960 8 жыл бұрын
Cheap US wiring of powerlines. No quality, just cheap so every mediocre dude can handle it. This is because they have no propper and long training, without learning the principles, ohm's law and so on. Every guy, which walks three days with a wrench and screwdriver in his hands, is called an electrical engineer. And when I see those transformers; for me they are looking like mop buckets, mounted at the top of a wooden pole. In words: poor, poor, quality; cheap materials.
@melmc8888
@melmc8888 8 жыл бұрын
What would you recommend to fix the shortcomings of these systems?
@steves009
@steves009 8 жыл бұрын
+Mel Mc look to a decent country like New Zealand the quality is way better. no hillbillies doing the job.
@eddygilbert9906
@eddygilbert9906 7 жыл бұрын
we have a four year 10,000 hour program :-/ Canada
@linemanap
@linemanap 7 жыл бұрын
Stephen Smith thats because the US has had electricity for well over a hundred years and and you sheep 🐑 lovers just got wired up its all new stuff over there.
@t0rm13
@t0rm13 6 жыл бұрын
Apprenticeship takes just as long to complete NZ as it does in the US. Something tells me you don't know how to use google.
Transformer Installation
4:52
CTE Skills.com
Рет қаралды 62 М.
How 3 Phase Transformers Work - why we need them
24:24
The Engineering Mindset
Рет қаралды 840 М.
Стойкость Фёдора поразила всех!
00:58
МИНУС БАЛЛ
Рет қаралды 5 МЛН
规则,在门里生存,出来~死亡
00:33
落魄的王子
Рет қаралды 26 МЛН
GIANT Gummy Worm Pt.6 #shorts
00:46
Mr DegrEE
Рет қаралды 108 МЛН
Which One Is The Best - From Small To Giant #katebrush #shorts
00:17
Padmount transformer service disconnect
11:42
Bobsdecline - Lineman blogger
Рет қаралды 155 М.
Chalk Talk: Transformer Selection
5:22
Northwest Lineman College
Рет қаралды 39 М.
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 6 МЛН
HOW TO: Vector Transformer Banks
25:23
Hiline Academy
Рет қаралды 14 М.
Corner Grounded Delta Transformer Bank
12:21
Three Phase Innovations
Рет қаралды 19 М.
Triphasic Infinite Energy Generator 10Kw 230V - Liberty Engine 1.1
17:33
The Liberty Engine Project
Рет қаралды 1,3 МЛН
Electrical Wire Color Coding Used By Electricians
16:14
Electrician U
Рет қаралды 748 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,2 МЛН
Стойкость Фёдора поразила всех!
00:58
МИНУС БАЛЛ
Рет қаралды 5 МЛН