19 year lineman just learned something. Thank you sir.
@paulx76205 жыл бұрын
Thank you reading this stuff is almost impossible for me to do, for me seeing a person and listening really helps.
@CTESkillscom11 жыл бұрын
Thanks ThedudeVip3r1990. Please like and subscribe. We'll be adding much more next semester.
@mohammedfofanah69887 жыл бұрын
so difficult i know the easy way for this system poor American system.
@phuxus5585 жыл бұрын
this guy is GREAT!!!
@vincentpereira84162 ай бұрын
So which transformer is the good for a house to carry 120 and 240v
@simplytrolling68693 жыл бұрын
“Thisin’ we can’t put on lighting it reads about two hunnn-erd ate volts two hunnn-erd ate volts on hunnn-erd twinny volt system dunn werk tew well, cause lotta smolk n stuff liiii dat”… this man speaks my language
@tedlahm5740 Жыл бұрын
Comment please. the term phase voltage and line voltage get interchange at times. Only place PHASE voltage can be measured at the transformer lug. Inside the property that would be the line voltage. comment please
@jolyonwelsh98347 жыл бұрын
You can use the high leg for modern LED light fixtures. Most of them have universal voltage drivers in them (100-277volts). Just make sure you use a straight rated 240 volt circuit breaker.
@beowens2315 жыл бұрын
Not a bad job at all sir :) Not enough young Lineman, out in the field, get to see 3 pot closed Delta Power only corner ground. Delta/ Delta or Wye /Delta corner ground, So in the future will you please show the Wye/Delta or Delta/Delta corner ground Two Pot Bank, they are rare but do exist. Thanks, Blane Owens.
@danielelise7348 Жыл бұрын
Here in Australia we just hang a single 3PH transformer & be done with it, although our voltage is 240/415V but each transformer feeds about 40 domestic installations,single phase,most 3PH installations have their own transformer.
@jimmybrad1568 ай бұрын
Out of interest, do you happen to know what those transformers weigh, and their VA rating? (The type you see on a wooden pole in a residential street.) Our place is 3ph but doesn't have its own transformer (WA). Not sure where it is to be honest. All I know is that once or twice a year, 1 of the phases will go 'brown', then a few minutes later all 3 will go dead. I guess they need to fix it and never get around to it.
@steves0098 жыл бұрын
Does the US have or use SWER (single wire earth return) systems not rural areas?
@metersocket007 жыл бұрын
Stephen Smith It depends on the utility supplier. I live in Exelón power territory (north east US) and they use wye systems, due to the old age of their lines. So SWER systems are very common here, especially in residential areas. But in newer installed systems, in rural or growing cities, they are primarily delta, so at least 2 phases are ran in those systems.
@heronimousbrapson8636 жыл бұрын
SWER is used in rural parts of Alberta, Canada.
@williammay53006 жыл бұрын
What about singal transformer connected to all 3 power lines??
@rtz54910 жыл бұрын
Why aren't all the connections on the transformers ever labeled?
@CTESkillscom10 жыл бұрын
rtz549 I don't have an answer for you on that. Maybe email Mr. Rusty @ Lamar Institute of Technology. That is where we filmed this. Thanks for watching and we do appreciate your question.
@FrankCerank10 жыл бұрын
Because on all Distribution transformers which have additive polarity the Primary bushings are H1 and H2 from left to right and the Secondary bushings are X1 X2 and X3 from right to left.
@yipster02908 жыл бұрын
That is incorrect. For additive polarity the secondary bushings will be labeled x3, x2 and x1. The primary bushings will always be labeled H1 and H2 regardless of the polarity of the transformer.
@linemanap8 жыл бұрын
Phil McCracken you just said the same thing he did lol
@steves0097 жыл бұрын
rtz549 cos Americans can't read
@steves0098 жыл бұрын
omg you make it look so hard. why the 3 transformers why not just one with 3 HV in?
@melmc88888 жыл бұрын
Lots of advantages doing it that way.
@steves0098 жыл бұрын
+Mel Mc don't see how. at least with 1 it can supply 3ph and single phase at the same time. Makes more work than needed
@melmc88888 жыл бұрын
+Stephen Smith 2 banks can be run as open Delta thus still supplying power to a business if one of the three fail...Also 3, 300 lb transformers are easier to transport and put on a pole than 1 that weighs 900 lbs
@steves0098 жыл бұрын
+Mel Mc well I have a 3ph transformer supplying my house and its rated at 100kva but only 1ph out and 3ph supplying the dairy shed and looks cleaner on the environment
@steves0098 жыл бұрын
+Mel Mc and only one set of HV wires from the HV line
@simplytrolling68693 жыл бұрын
6:28 the dude hollerin
@arturoalmanza14826 жыл бұрын
Yeah rusty
@lendavidhart97105 жыл бұрын
That power leg, some guys call it a bastard leg
@redshift19763 жыл бұрын
That guy in the red jumpsuit looks like a real dummy 6:53
@firefightr_spike38463 жыл бұрын
ahahah I see what you did there 😂
@jolyonwelsh98346 жыл бұрын
Why bother with a wye primary? Use a Delta primary thus doing away with the risk of feroresonance in the first place. Just about all your 3 phase dry type transformers have Delta primaries probably for that very reason.
@REWYRED11 жыл бұрын
Interesting! 4 wire delta is unheard of where I am, 3-wire ungrounded delta ( with use of ground indicator lights) and open delta were common but are rare now.. Basically all there is to choose from for low voltage 3 phase power here is 120 / 208V or 347 / 600V.... 347V being a common voltage for commercial lighting.
@jolyonwelsh98347 жыл бұрын
Long be the high leg.
@rafalszachnowicz28314 жыл бұрын
Haaaaaaa! It's easier to understand if someone simply tell you what's what, isn't it?
@mca19608 жыл бұрын
Cheap US wiring of powerlines. No quality, just cheap so every mediocre dude can handle it. This is because they have no propper and long training, without learning the principles, ohm's law and so on. Every guy, which walks three days with a wrench and screwdriver in his hands, is called an electrical engineer. And when I see those transformers; for me they are looking like mop buckets, mounted at the top of a wooden pole. In words: poor, poor, quality; cheap materials.
@melmc88888 жыл бұрын
What would you recommend to fix the shortcomings of these systems?
@steves0098 жыл бұрын
+Mel Mc look to a decent country like New Zealand the quality is way better. no hillbillies doing the job.
@eddygilbert99068 жыл бұрын
we have a four year 10,000 hour program :-/ Canada
@linemanap8 жыл бұрын
Stephen Smith thats because the US has had electricity for well over a hundred years and and you sheep 🐑 lovers just got wired up its all new stuff over there.
@t0rm136 жыл бұрын
Apprenticeship takes just as long to complete NZ as it does in the US. Something tells me you don't know how to use google.