Trialling Fire rated cable clips for 18th Edition compliance Linian Fire Clip Fast Fix

  Рет қаралды 10,603

Artisan Electrics

Artisan Electrics

Күн бұрын

Trying out these Linian Fire Clips during a fire alarm and emergency lighting installation, how did I get on with them?
They are very easy to install, drill one hole and then after wrapping the clip around the cable, simply push in.
They stay in pretty well, due to the barbs on the fixing. Super quick to install and look good.
Comply with 18th Edition regulations with this new fire clip for round cables.
🧰🛠️ Tools Of The Day 👇
You can buy the red ones here: amzn.to/2NHcw6c
White ones here: amzn.to/2VypBRW
Double White clips here: amzn.to/2C4EOCR
Black ones here: amzn.to/2NBIZKS
🔔 Subscribe to TOOLS4SPARKS KZbin Channel 👇
I Also Have A Dedicated KZbin Channel About Tools:
➤ / tools4sparks
Free Stuff for my Subscribers:
Free Amazon Prime for 30 days here:
www.amazon.co....
Free Amazon Music Unlimited for 30 days here: www.amazon.co....
Free Audio Books for 30 Days here:
www.amazon.co....
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co....
📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
#Electrician #SparksLife #Cambridge #ArtisanElectrics

Пікірлер: 41
@hypersampers6681
@hypersampers6681 Жыл бұрын
Being using these clips for years, brilliant and versatile. Dont go over 250mm between clips to avoid sagging
@felixstowecarpentryandjoin1640
@felixstowecarpentryandjoin1640 5 жыл бұрын
I’m not a sparkie but I do enjoy watching all tradesman videos, you’ve got a great channel mate. What I REALLY hate is seeing keyboard warriors writing very rude negative comments, if you’ve watched something u don’t agree with or u think u have a better way of doing things then constructive criticism is fine but there no need to be so rude . If u don’t like what you’ve seen don’t watch no more . Most people making utube vids are making no money from it , its actually costing them money to make them . If people keep leaving such rude negative comments the people will stop making vids. Rant over , keep up the good work bud 👍
@artisanelectrics
@artisanelectrics 5 жыл бұрын
Thanks a lot I appreciate your comments, your so right!
@christophergallagher3845
@christophergallagher3845 Жыл бұрын
You're right ppl are cruel by what you have to remember is the criticism is coming from professionals and although minor details may seem minor to casual viewers there's reason electricians must stick to the regs . Especially when doing alarms and essential services
@willford8475
@willford8475 5 жыл бұрын
Bars in the window? It looks like the Stationery Cupboard in Wormwood Scrubs! 😉👍
@christieintruderalarms4649
@christieintruderalarms4649 5 жыл бұрын
That install is shocking! Also anything under 2m should be mechanically protected
@artisanelectrics
@artisanelectrics 5 жыл бұрын
Christie Intruderalarms thanks for your feedback.
@wonderboy2016
@wonderboy2016 5 жыл бұрын
Always keep your fire alarm cables separated from your mains 50mm minimum 👌
@aj010139
@aj010139 4 жыл бұрын
I'm shocked that this wasn't done. Thought the regs state circuits for safety services need to be segregated.
@christophergallagher3845
@christophergallagher3845 Жыл бұрын
There was an episode on grand design years ago there was this special house being built by a guy for his wife who was deaf . In the house a system was fitted to help work with her hearing aids and boost her hearing in her home to give her near perfect hearing . The system didn't work nce the house was finished due to interference from all the mains supplies running through the house to the millions of downlights etc they had installed . It was a shame it didn't work due to interference
@cantbelieveimhere2935
@cantbelieveimhere2935 Жыл бұрын
Not sure of the Brittish Standards, but over here it's 300mm.
@154electrician
@154electrician 5 жыл бұрын
They look pretty bad , should have used T2 trunking and then used them inside the trunking to comply with the regs
@artisanelectrics
@artisanelectrics 5 жыл бұрын
electrician154 yeah I agree, it was just an experiment
@mlee6050
@mlee6050 Жыл бұрын
@@artisanelectrics from what read how enforced is it? I wired a cable over front door but maybe as firm cable the electrician here not say it back, only plastic clips Also what read is for if cable fall in fire over an exit so can I go without along a wall? Looking to add a wire for 2kw heater and put wire so electrician can wire end into consumer unit (am tempted to do it and have them check it next time about)
@focusrstguy7759
@focusrstguy7759 3 жыл бұрын
Clips on ceiling over 300mm and no cable segregation.. also over lapping looks terrible id say not compliant and not quality work.. another sparks fucking with the fd&a system...
@craigmcroberts5372
@craigmcroberts5372 5 жыл бұрын
Surely you’ve no left the cabling like that on the ceiling absolutely shocking
@frankbennett8877
@frankbennett8877 5 жыл бұрын
That ceiling looks a mess.
@artisanelectrics
@artisanelectrics 5 жыл бұрын
Frank Bennett yeah a few too many holes in there but filled them all afterwards.
@tomdavis8827
@tomdavis8827 3 жыл бұрын
I don't think he means the holes, the cables look a mess lol
@stephenpower9572
@stephenpower9572 5 жыл бұрын
Not seen them in use before. Look ok for use in hidden areas or out of reach. Would you say a p clip is a more secure fixing for say running cable into a call point unit.
@artisanelectrics
@artisanelectrics 5 жыл бұрын
Stephen Power P clips definitely hold the cable tighter if you get the right size. These things are quite solid though.
@antonios4926
@antonios4926 4 жыл бұрын
Thanks for your many videos of which i enjoy. Can we run fire alarm cables with lighting and socket cables all together in steel trunking? Or do the fire cable need to be separate?
@antonios4926
@antonios4926 4 жыл бұрын
Found out the answer. No, fire cables must be run separately from other 230v cables.
@tomdavis8827
@tomdavis8827 3 жыл бұрын
No, fire alarm cables are be separate to mains cables
@antonios4926
@antonios4926 3 жыл бұрын
@@tomdavis8827 Thanks for the reply.
@thomasbyles3075
@thomasbyles3075 5 жыл бұрын
Nice work, thanks for the videos
@artisanelectrics
@artisanelectrics 5 жыл бұрын
Thanks!
@damonbtc9701
@damonbtc9701 5 жыл бұрын
How do u feel about wrapping some 1mm around the cables with screws and washer's?... something I've done a long time before these manufacturers started putting 18th complient on there wares....?
@zedman442
@zedman442 4 жыл бұрын
Then the issue arises with how to fix those screws into masonry. Using plastic plugs again? Small masonry anchors are too cumbersome, you are back to square one again.
@Stop..carry-on
@Stop..carry-on 5 жыл бұрын
Personally I think that looks bloody ugly all that cabling on show on the Ceiling , much prefer hidden in trunking
@mkinili2527
@mkinili2527 4 жыл бұрын
I personally think this was not a real installation more for demonstration since anything below 2m should be in a containment or trunking as well as you simply cannot mix ELV with LV . So they just demonstrating the lilian stuff. Arghh.. some people Thanks for the Demo!
@artisanelectrics
@artisanelectrics 4 жыл бұрын
You're welcome!
@Lifeguruonafence
@Lifeguruonafence 4 жыл бұрын
Will these work in concrete?
@artisanelectrics
@artisanelectrics 4 жыл бұрын
Yes they will
@darrylmars616
@darrylmars616 5 жыл бұрын
No conduit under 2.1! Amateur
@artisanelectrics
@artisanelectrics 5 жыл бұрын
Is that in the fire alarm regs?
@artisanelectrics
@artisanelectrics 4 жыл бұрын
Thanks is that specifically only in fire alarm regs?
@aj010139
@aj010139 4 жыл бұрын
So basically If you got no training on bs5839 you can go ahead and work on life saving & safety services in a commercial enviroment.. great!!
@corkevans4217
@corkevans4217 2 жыл бұрын
I like you videos, but there’s nothing right about that fire alarm installation (apart from the fact you’ve used FP). I don’t believe you’ve wired this purely to demo the fire clips BTW, which means some poor bugger’s paying for it. 1. Looks dreadful 2. Should have mechanical protection (MT2 is good) 3. No separation of LV and ELV circuits.
FP200 Gold Cable + Flames = ?
13:33
John Ward
Рет қаралды 21 М.
Comfortable 🤣 #comedy #funny
00:34
Micky Makeover
Рет қаралды 17 МЛН
Prank vs Prank #shorts
00:28
Mr DegrEE
Рет қаралды 7 МЛН
Pool Bed Prank By My Grandpa 😂 #funny
00:47
SKITS
Рет қаралды 19 МЛН
How I Did The SELF BENDING Spoon 😱🥄 #shorts
00:19
Wian
Рет қаралды 36 МЛН
U.K. Electrics SUCK! This is what we should be doing…🇫🇷
19:17
Artisan Electrics
Рет қаралды 187 М.
Quick & tidy EV installation with LINIAN SuperClips
2:15
LINIAN Clip
Рет қаралды 1,2 М.
LINIAN Main Overview Video
2:18
LINIAN Clip
Рет қаралды 924
Can I Use Connectors Inside Trunking to Extend Cables?
5:43
FP200 Termination
10:26
E Learning Resources
Рет қаралды 28 М.
D-Line Safe D - Fire Cable Fixing Clip for Trunking
2:27
TLC Electrical Distributors
Рет қаралды 8 М.
Linian Clip Advert
1:09
LINIAN Clip
Рет қаралды 1,9 М.
How to Clip Twin and Earth Cable Like a Professional
15:28
GSH Electrical
Рет қаралды 16 М.
Comfortable 🤣 #comedy #funny
00:34
Micky Makeover
Рет қаралды 17 МЛН